Introduction
The 811LMX and 813LMX are programmable
DIP switch remote controls for use with
LiftMaster commercial products using Security+
2.0® Encrypted DIP, as well as older 315 MHz
DIP or 390 MHz DIP devices. The remote control
default setting is Security+ 2.0®.
The 813LMX model is designed for OPEN/
CLOSE/STOP functionality.
The images throughout this manual are for
reference only and your product may look
different.
1 Slide the cover open to access the DIP
switches.
2 Use a pen or screwdriver to slide the DIP
switches to any position you want (ON or OFF).
811LMX 813LMX
WARNING: This product can expose you
to chemicals including lead, which are
known to the State of California to cause
cancer or birth defects or other
reproductive harm. For more information
go to www.P65Warnings.ca.gov.
To prevent possible serious injury or death from
a moving gate or garage door:
• ALWAYS keep remote controls out of reach
of children. NEVER permit children to
operate, or play with remote control
transmitters.
• Activate gate or door ONLY when it can be
seen clearly, is properly adjusted, and there
are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight
until completely closed. Never permit anyone
to cross path of moving gate or door.
PROGRAMMABLE DIP SWITCH
REMOTE CONTROLS
Models 811LMX and 813LMX
Programming
Step 1: Set the DIP Switches
Cover
DIP
Switch
OFF
ON
12 11 10 9 8 7 6 5 4 3 2 1
NOTE: If you are ‘matching’ the DIP switch setting
from an existing 61LM or 361LM, your original
remote setting cannot be using ANY of the center
‘0’ settings and Position 1 must be in the OFF
position. If your original remote does have any ‘0’
settings or Position 1 in the ON position, please
select a new DIP setting on your 811LMX and
program it into your commercial receiver. Any
future 811LMX remotes will copy this setting and
will be programmed to the appropriate Security
Type.
Learn Buttons
Example: Your receiver or
operator may look different.
See your LiftMaster device’s manual for
programming.
1 Press and release the LEARN button on your
device.
2 Within 30 seconds press and hold the button on
the remote control that you wish to program to
the device.
3 Test by pressing the remote button you just
programmed. The operator or gate activates.
Additional buttons on the 813LMX can be
programmed to operate other devices of the same
security type.
The 813LMX can be programmed for OPEN/
CLOSE/STOP functionality. Refer to your device
manual for instructions.
Step 3: Program the Remote to a Device
Open, Close, Stop
Yellow
LED
Follow these steps to select 315 MHz DIP, 390
MHz DIP or to reset the remote to Security+ 2.0®
Encrypted DIP from a
different setting.
1 Locate and press
the Program
Button. The LED
glows steady
Yellow.
Step 2: Select the Security Type
NOTE: If the device you use with this remote is
Security+ 2.0® Encyrpted DIP, skip this step and go
to Step 3: Program the Remote to a Device.
2 Press any remote control button the number of
times that corresponds to the security type for
your device.
3 Press and hold the Program Button until the
LED on the front of the remote turns off.
Program
Button
# OF PRESSES DEVICE SECURITY TYPE
1Security+ 2.0® (811LM/813LM)
2315 MHz DIP (361LM/333LM)
3390 MHz DIP (61LM/33LM)
The Remote Control Battery
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify
doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V CR2032 coin batteries.
• DO NOT recharge, disassemble, heat above
212°F (100°C) or incinerate.
The lithium battery should produce power for
up to 3 years. To replace battery:
Replacement Parts
Visor Clip .................................................................. K029B0137
3V CR2032 lithium Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K010A0020
NOTICE: To comply with FCC and/or Industry Canada (IC) rules,
adjustment or modifications of this transceiver are prohibited. THERE
ARE NO USER SERVICEABLE PARTS.
This device complies with Part 15 of the FCC rules and IC RSS-210.
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Remote 811LMX or (IFT#: _____________)
Operation of this equipment is subject to the following two conditions:
(1) This equipment may not cause harmful interference, including that
which may cause undesired operation.


Produktspezifikationen

Marke: LiftMaster
Kategorie: Nicht kategorisiert
Modell: 811LMX

Brauchst du Hilfe?

Wenn Sie Hilfe mit LiftMaster 811LMX benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert LiftMaster

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-