Lasko 1128 Bedienungsanleitung


Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Lasko 1128 (2 Seiten) in der Kategorie Luftbefeuchter. Dieser Bedienungsanleitung war fĆ¼r 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Congratulations on your purchase of the Recirculating Console Humidiī€Ÿer. Featuring the unique use of pump driven water
circulation, this unit provides exclusive features that no other humidiī€Ÿers offer.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT INFORMATION and FEATURES
Your Recirculating Console Humidiī€Ÿer is an EVAPORATIVE TYPE
HUMIDIFIER. This means that the air being drawn through the
moistened filter naturally evaporates the water and disperses
INVISIBLE MOISTURE into the air. This type of humidiī€Ÿer DOES
NOT PRODUCE MIST, WATER DROPLETS, STEAM OR EXCESSIVE
CONDENSATION associated with other types of humidiī€Ÿers.
EXCESSIVE HUMIDITY CAN OFTEN LEAD TO UNANTICIPATED
PROBLEMS. Air containing water droplets or mist can create a good
habitat for the growth of mold and mildew.
Misting units often oversaturate the air, while the Lasko Recirculating
Console Humidiī€Ÿer reaches a maximum humidity output level
without oversaturating. With a properly operating Evaporative
Humidiī€Ÿer, the evaporation rate increases naturally when the air
is dry. When the humidity in your home is high, moisture output
automatically decreases to help prevent damaging condensation.
The Watershow Viewing Window provides a visible way for you to
know that your Recirculating Console Humidiī€Ÿer is operating. As
air passes over the ī€Ÿlter, the humidity in the room will increase, and
the water level in the Unit will begin to decrease.
Unlike misting humidiī€Ÿers, the Evaporative Filter in your Recirculating
Console Humidiī€Ÿer also traps unwanted minerals that reside in nor-
mal tap water. This ī€Ÿltering also assures there is NO WHITE DUST
dispersed into the air.
DO NOT pour water
into Grill. DO NOT spill
water on Control Panel.
Water should only be
poured into the Unit
using the Jug.
Rev. F 6/08 1 2084256
ASSEMBLY
CAUTION: DO NOT ī€Ÿll unit before assembling.
1. Remove Water Jug then,
Upper Housing from base
of unit. (Figure 1)
2. Lay base of unit on itā€™s side
so the bottom of the unit is
facing you.
3. Fully insert the four Castors
into the holes in the bottom
of the unit. (Figure 2)
4. Replace Upper Housing,
then Water Jug into unit.
Figure 1
Base
Upper Housing
Water Jug
Rev. F 6/08 4 2084256
Fan not working or ā€¢ No power Make sure Unit is plugged in
Humidiī€Ÿer doesnā€™t Check that the Power Switch is on
turn on ā€¢ Humidistat not set correctly Set Humidistat to higher humidity level
Water leaking ā€¢ Base is overīƒ„lled Reduce water level in Base
ā€¢ Filter is old and dirty Replace Filter
Foul odor ā€¢ Filter needs to be replaced Replace Filter
ā€¢ Base needs to be cleaned Follow Cleaning Instructions
ā€¢ Whole Humidiīƒ„er needs cleaning Follow Cleaning Instructions
Filter discoloration ā€¢ Mineral deposits in water Replace Filter
Water discoloration ā€¢ Humidiīƒ„er needs to be cleaned Follow Cleaning Instructions
ā€¢ Hard water - Iron in water Use īƒ„ltered or distilled water
ā€¢ Some humidiīƒ„er additives can cause
discoloration
Lights donā€™t work:
Humidistat Light Off, ā€¢ Humidity is not yet achieved in room Let Humidiīƒ„er continue to run
Power Light On
Power Light Off, ā€¢ Room has reached desired Humidity level Set Humidity Knob for more Humidity
Humidistat Light On
No water show ā€¢ Hose not connected to Pump Connect Hose to Pump
ā€¢ Hose not connected to Water Show Connect Hose to Water Show
ā€¢ No Water in Unit Reīƒ„ll Unit
TROUBLE PROBABLE CAUSE SOLUTION
TROUBLE SHOOTING GUIDE EVAPORATIVE HIGH PERFORMANCE
RECIRCULATING CONSOLE HUMIDIFIER Model 1128
NOTE: A few droplets of water may be present in
your humidiī€Ÿer as a result of our quality testing
prior to packaging and shipment.
When using electrical appliances, basic precautions should always
be followed to reduce the risk of ļ¬re, electric shock and injury to
persons, including the following:
1. Make certain that the power source conforms to the electrical
requirements of the Humidiļ¬er.
2. Where possible, avoid the use of extension cords. If you must
use an extension cord, minimize the risk of overheating by us-
ing the shortest cord possible and ensuring that it is UL Listed.
NEVER use a single extension cord to operate more than one
appliance
3. Do not insert ļ¬ngers or foreign objects into the Humidiļ¬er. Do not
block or tamper with the Humidiļ¬er in any manner while it is in
operation. NEVER tilt or attempt to move the Humidiļ¬er while it is
operating.
4. Always unplug the Humidiļ¬er before ļ¬lling, servicing or moving
the Humidiļ¬er.
WARNING: DO NOT DEPEND ON THE ON/OFF KNOB AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN FILLING,
SERVICING or MOVING THE HUMIDIFIER. ALWAYS UNLPUG
THE POWER CORD.
5. This Humidiļ¬er is intended for general use only. It must NOT
be used in potentially dangerous locations such as ļ¬‚ammable,
explosive, chemical-laden or wet atmospheres.
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK -
DO NOT USE THIS HUMIDIFIER WITH ANY SOLID STATE SPEED
CONTROL DEVICES.
6. Always place the humidiļ¬er on a stable, ļ¬‚at level surface when
operating, to avoid the risk of the Humidiļ¬er overturning. Locate
the power cord so the Humidiļ¬er or other objects are not resting
on it. Keep the power cord away from room trafļ¬c.
7. Do not place Humidiļ¬er near a heat source such as stoves,
radiators or heaters.
This appliance has a polarized plug (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended
to ļ¬t in a polarized outlet only one way. Match wide blade of
plug to wide slot. Fully insert. If the plug does not ļ¬t fully in the
outlet, reverse the plug. If it still does not ļ¬t, contact a qualiļ¬ed
electrician. DO NOT attempt to defeat this safety feature.
This plug is a safety feature, to reduce the risk of ļ¬re, electric
shock and personal injury. DO NOT remove, replace, repair or
tamper with the originally supplied plug. If the Fan does not
function properly, it may be due to the safety device incorpo-
rated in this plug. Return to an authorized service center or call
800-233-0268, Monday - Friday, between 8:00 a.m. and 5:00 p.m.
EST. If the plug warning label is missing or damaged, call the toll
free number for a replacement label.
8. Always direct air ļ¬‚ow away from walls or furniture as excessive
moisture may cause damage.
9. Humidiļ¬ers require regular cleaning to maintain proper operat-
ing conditions. Refer to CLEANING and FILTER CARE for proper
cleaning procedures.
10.Do not place Humidiļ¬er on an electrical appliance.
11.This Humidiļ¬er is not suitable for use in agricultural facilities
including areas where livestock, poultry or other animals are
conļ¬ned. Please refer to National Electric Code (NEC) Article
547-7 (2008), or applicable state or local codes or standards
relating to electrical requirements for Agricultural Buildings.
THIS HUMIDIFIER DOES NOT MEET THE REQUIREMENTS OF
NEC ARTICLE 547-7 (2008).
12.This Humidiļ¬er is not suitable for use in hazardous locations.
Please refer to National Electric Code (NEC) Article 500 or appli-
cable state or local codes or standards relating to electrical
requirements for Hazardous locations. THIS HUMIDIFIER
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE
500 (2008).
GENERAL SAFETY INFORMATION
Figure 2
Hole
Castor
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date
of original purchase or until the original purchaser of the product sells or transfers the product, whichever ļ¬rst occurs.
WHAT LASKO WILL DO: During the warranty period, Lasko will, at its sole option, repair or replace any part or parts that prove to be defective
or replace the whole product with the same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper
handling or operation, shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the
return of products to Lasko for repair or replacement. Lasko will pay return shipping charges from Lasko following warranty repairs or replacement .
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF
MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE
PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL LASKOā€™S LIABILITY UNDER
ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR
(II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE
CONTRARY, IN NO EVENT SHALL LASKOā€™S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF
THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential
damages, so these exclusions or limitations may not apply to you. This warranty gives you speciļ¬c legal rights. You may also have other rights
which vary from state to state and province to province.
Proof of purchase is required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 233-0268 . Email: producthelp@laskoproducts.com
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts.
They can be reached Monday through Friday, 8am-5pm Eastern. Please have your model number available, as well as the type
and style.
CAUTION: Do not pour water through
the Exhaust Grill on the Upper Housing.
Doing so may cause damage and personal
injury.
CAUTION: Unplug Unit when ī€Ÿlling. ā€¢
ā€¢ Always place Humidiī€Ÿer on a ī€Ÿrm level surface.
Locate the Power Cord so the Humidiī€Ÿer is
not resting on it, and is away from trafī€Ÿc.
ā€¢ Be careful not to overīƒ„ll.
ā€¢ Do not pour water through Exhaust Grill,
doing so may cause damage and personal injury.
ā€¢ Take extra care to prevent water spillage
that may damage furniture or flooring. The
manufacturer will not accept responsibility for
damage to property caused by water spillage.
ā€¢ Always be sure the Power Knob is in the OFF
position when plugging Humidifier into a
grounded 120 volt AC wall outlet.
ā€¢ To prevent risk of electrical shock and injury to
persons, do not plug Humidiī€Ÿer into electrical
outlet with wet hands.
1. It is recommended that all Humidiīƒ„ers be cleaned prior to use.
Please read for Base and Jug cleaning.Cleaning Instructions
2. Use the convenient Carrying Handle found on the bottom of
the Water Jug to bring it to a faucet. The Water Jug features a
ā€˜Quick Fill/Quick Emptyā€™ Spout. To ī€Ÿll, hold Jug upside down
by the Handle. Use thumb to press down Stopper Lever, and ī€Ÿll
Jug. Fill the Water Jug with cool tap water. Never use hot water.
(Figure 3)
When the Jug is replaced back into the Base it will quickly empty
to ī€Ÿll Base.
NOTE: While carrying ī€Ÿlled Water Jug back to the Humidiī€Ÿer, hold
the Handle with one hand, while supporting bottom of Water Jug
with other hand.
3. Place the Water Jug securely in the Base. If positioned
properly, water will quickly pour into Base and automatically
stop when reaching desired amount.
4. When gurgling noise stops lift up the Water Jug to see if it is empty.
Reī€Ÿll if empty. When the Unit is full some water will remain in
the Jug.
5. Even though your Humidiī€Ÿer will produce approximately 9.0
gallons in a 24 hour period*, the water capacity (amount of
water the Humidiī€Ÿer will hold at one time) is 4.5 gallons.
(3 FULL Jugs).
FILTER CARE
Rev. F 6/08 2 2084256 Rev. F 6/08 3 2084256
Figure 5
The presence of water ī€žow in the Water Show Window indicates
the circulation of water to the Filter. (Figure 5)
1. Clean and dry Humidifier thoroughly per the Cleaning
Instructions. Do not leave any water in the Unit when stor-
ing.
2. Dispose of the Evaporative Filter Pad. Do not store used
Evaporative Filter Pad in the Humidiī€Ÿer.
3. Place Humidiī€Ÿer back into its carton and store in a cool dry
place.
OFF-SEASON STORAGE
NOTE: The Humidiī€Ÿer will only turn on when the Humidistat is set to
a high enough setting or when the room humidity is low enough.
Figure 6
The Filter inside your Humidiī€Ÿer plays a very important part in
its operation. In order to maintain peak performance, it is highly
recommended to use only LASKO REPLACEMENT FILTERS. Some
imitation ī€Ÿlters do not comply with Laskoā€™s quality standards,
resulting in decreased performance of your Humidiī€Ÿer.
CAUTION: To prevent electric shock, always turn Power
Control Knob to OFF position and unplug before servicing.
1. To replace the Evaporative Filter Pad, remove the Jug and Upper
Housing from the Base. Be careful not to let excess water from
pump spill onto furniture or ī€žooring.
2. Remove Evaporative Filter Pad Holder from Base and inspect
Small Water Drip Holes for any blockage. (Figure 7)
Figure 7
3. To open the Filter Holder apply outward pressure to the two
snaps and it will hinge open. Remove used Filter from Holder
and discard. (Figure 8)
Figure 8
4. Insert new Filter into Holder, snap closed, and reinstall Holder
into Base. (Figure 7) The Filter will only ī€Ÿt into the Holder one
way. Make sure the Rounded side of the Filter Holder is facing
outward. Replace Upper Housing, then Water Jug into Base.
5. To increase the life of your Filter Pad turn
Filter around (so the bottom of Filter is now
at the top).
6. Filter life may be extended by cleaning the
Filter in a 20% vinegar solution. To clean
Filter, mix one part undiluted vinegar with
four parts warm tap water. Soak the Filter in this solution for
20 minutes, rinse Filter thoroughly with warm water to remove
vinegar odor.
CLEANING
DO NOT FLATTEN, SqUEEzE OR TWIST FILTER WHEN CLEANING
7. Discoloration of the Evaporative Pad is normal after
extended use. The discoloration is caused by mineral deposits
in the water, and the degree of discoloration will vary depend-
ing upon the amount of mineral content in the water. When
the Filter surface area is thoroughly discolored, or you notice
reduced water usage, it is a good indicator that the Filter
Pad needs to be replaced. The Evaporative Pad should be
replaced at least once every season.
The Replacement Filter to be used in this unit is:
The Lasko Replacement Evaporative Pad Model THF 8
(Available separately)
Humidistat
Knob
GREEN Hu-
midistat
Light
Filter Pad Holder
Base
Drip Holes
Snaps
Evaporative Filter Pad
Figure 3
Water Capacity of Unit is 4.5 Gallons
Carry Handle
Stopper Lever
Quick Fill /
Quick Empty
Spout
Figure 4
Power Knob
RED Power
Light
1. Regular cleaning is necessary to ensure proper and
efī€Ÿcient operation. The frequency of cleaning depends on the
amount of impurities which may be found in the water or how
often the Humidiī€Ÿer is in operation. In either instance, it is
recommended that the Humidiī€Ÿer be cleaned at least once
a week.
NOTE: The bottom of the Jug may
be unscrewed for easy cleaning.
(Figure 9)
CAUTION: Make sure bottom of
jug is securely fastened to Jug
before reinstalling into Base.
2. TO DESCALE BASE AND JUG:
Mix one part undiluted white
vinegar with four parts warm
tap water. Let vinegar solu-
tion stand for 20 minutes then
wipe away any scale buildup
using a soft brush or cloth. Do
not use soap or detergents
and never use an abrasive
cleaner.
3. TO DISINFECT BASE AND JUG: Fill Jug with 1 teaspoon of
chlorine bleach and 1 gallon of water. Let solution stand for
20 minutes. Carefully empty Jug and rinse well with water until
bleach smell is gone.
4. Commercial ā€œDescalersā€ and ā€œBacteriostatsā€ are available at
your local home improvement center.
5. Do not operate Humidiīƒ„er when there is still cleaner in the
water.
FILLING and OPERATION
(Jug Holds 1-1/2 Gallons)
(Base Holds 3 Gallons)
Figure 9
6. Turn Power to desired speed. ON (Figure 4)
3 - For fast humidification of a large room or house,
approximately 9 gallon per day.*
2 - For normal operation.
1 - For quiet, night time operation or after desired moisture
level is reached.
* Calculations based on ambient room conditions of 70Ā° F
and 30% relative humidity in a room of average insulation.
NOTE: Power Light and Fan are on only when the Humidistat is
turned to a high enough moisture setting.
7. To set Humidistat to desired level turn Knob towards HIGH
until the power is ON. After the room has reached a comfort-
able humidity level, turn the Humidistat Knob slowly towards
LOW until the fan shuts off and the Green Light turns on, the
Humidifier will automatically restart when humidity falls
below this setting. (Figure 6)


Produktspezifikationen

Marke: Lasko
Kategorie: Luftbefeuchter
Modell: 1128

Brauchst du Hilfe?

Wenn Sie Hilfe mit Lasko 1128 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftbefeuchter Lasko

Bedienungsanleitung Luftbefeuchter

Neueste Bedienungsanleitung fĆ¼r -Kategorien-