INTENDED USE · IRT-100
Thank you for purchasing our Infrared Thermometer, type
AET-R1D1. This Infrared Thermometer is a non-sterile,
reusable, handheld device. It can be used by consumers in
homecare environment and doctors in clinic as reference.
It is intended for measuring human body temperat ure of
three months and above of people by detecting infrared
heat from the center of the forehead.
·
The clinical thermometer is an adjust ed mode clinical
thermometer.
· The patient can use and maintenance the device as an
operator.
· For safe and proper use of this product, be sure t o read
and fully understand Safety Precaut ions contained in
this user manual.
· Keep this manual wit h you for a convenient reference.
· Keep this manual in a proper way and avoid any loss.
·
If you need other information, please cont act the
manufactu rer.
The correct measurement
method to follow:
Measure the forehead. Distance 15mm to 50mm.
CORRECT MEASUREMENT METHOD
1 Turn t he thermometer on by pressing the
“SCAN” but ton. A beep sound will be heard
following which the screen will with ---°C
indicating the unit is ready for use.
2 Place the thermometer probe point near the
forehead and press “SCAN” and release after ~
1 second and the thermometer will beep and
display the accurate temperature. Whenever
consecutive readings are required, please wait
for at least 5 second. The above procedur e can
be repeated as many times as required.
3 To turn o the device press and hold the “SCAN
switch for ~ 5 seconds. Or the thermometer will
turn o automatically after ~ 60 seconds.
UNIT DESCRIPTION
Display information
Location indication: The icon indication the correct mea-
suring position when measuring.
Temperature data indication: The temperature reading is
displayed after measuring.
Temperature unit indication: Unit of measuring temperature
shows °C or °F.
Low battery symbol indication: the icon prompts you to
replace the battery when the power is low.
Memory symbol indication: it shows in memory query
mode currently.
LOAD AND REPLACE BATTERIES
Batt eries need replace when the icon “ ” is display on
the screen. The steps as follow:
1 Press and hold the bat tery cover, and push it
upward diagonally to push the cover away.
2 Install 2*AAA batteries as shown in
the positive and negative pole.
3 Close the battery cover.
Warning:
·
Please t ake out the batter y if you do not use the thermo-
meter for a long time.
· Please refer to the relevant laws and regulations for the
disposal of waste batteries.
· Do not mix old and new batteries;
· -Do not mix alkaline, st andard (carbon-zinc), or rechar
geable (Ni-Cd, Ni- MH, etc.) batteries.
BEFORE TAKE A MEASUREMENT
1 It is suggested to try the device by yourself
rst , so as t o know how to use it.
2 In order to avoid aecting accuracy of the device
due to the external too cold or too hot environment,
it must be placed in general environment of room
temperature of 16°C -35°C for at least 30 minutes
before use to avoid incorrect measurement results.
3 The person measured should be kept at
room temperature for at least 20 minutes
to make body temperature balanced.
4 After strenuous exercise, you should rest for at
least 30 minutes before taking measurement.
5 Wipe the skin dry and push aside hair
strands before commencing.
6 When repeated measurements are made
continuously, move away the probe bet ween
each measurement and rest for at least 5s before
making the next to obtain the most correct result.
7 The normal reading value is about 35.5°C ~ 37.8°C.
The user should take more temperat ure to
know his or her own health temperature.
Pay at tention to physical changes or consult
your doctor if there is any abnormality.
8 Check t he probe is clean before each
measurement to ensure accuracy.
INSTRUCTIONS FOR USE
1 Press the “SCAN” key. The display is activated
to show all segments for 1 second.
2 The last measurement reading will automatically be
shown on the display for 1 second wit h the “M” icon.
3 When the “---°C“ display, a beep sound is heard
and the thermometer is ready for measurement.
4 Aim the thermometer at the center of the
forehead with a dist ance of 15mm to 50 mm.
5 Press the “SCAN” key, after 1 second a long beep will
verify the completion of measurement .
If a reading below 32°C is recorded a “Lo” sign will
be displayed followed by 2 consecutive beeps.
If a reading above 37.8°C is recorded there will be 6
consecutive beeps.
If a reading above 42.2°C is recorded a “Hi” sign will
be displayed followed by 2 consecutive beeps.
6 Press the “SCAN” key for 5 seconds to turn
o the thermometer. Or the unit will switch
o automat ically after 60 seconds.
Recalling Readings from Memory
In shutdown mode, long press the “SCAN” key for 4s unt il
the screen is display “M, then release and the screen
display ”01 => 36.C”, and then press the “SCANkey
to display the next reading in a sequence from the last
reading to the rst reading.
The thermometer has the memory to recall the last 32 readings.

Produktspezifikationen

Marke: Lanaform
Kategorie: Thermometer
Modell: IRT-100
Akku-/Batterietyp: AAA
Akku-/Batterietechnologie: Alkali
Verpackungsbreite: 54 mm
Verpackungstiefe: 54 mm
Verpackungshöhe: 165 mm
Paketgewicht: 100 g
Display: LED
Typ: Fernabtastthermometer
Automatische Abschaltung: Ja
Verpackungsart: Box
Anzahl unterstützter Akkus/Batterien: 2
Akku-/Batteriespannung: 1.5 V
Speicherkapazität: 32 Eintragungen
Akkus/Batterien enthalten: Ja
Speicherfunktion: Ja
Maßeinheit: °C, °F
Position des Thermometers: Stirn
Messzeit: 1 s
Hochtemperatur-Alarmeinstellung: Ja
Speicher für letzten Messwert: Ja