Model PACKA53,
PACKA53-22050 and PACKA53-22060
Port-A-Cool, LLC • 709 Southview Circle • Center, TX 75935
www.kuulaire.com • 1-888-999-6511
Introduction
The PACKA53, PACKA53-22050, and PACKA53-22060
feature a 3-speed fan and automatic timer that can
be programmed for up to up to 8 hours in 0.5 hour
intervals. The automatic louver swing function provides
directional control and the remote control (batteries not included),
provides convenience. The PACKA53, PACKA53-22050, and
PACKA53-22060 portable evaporative cooler is the latest
in evaporative cooling technology from Port-A-Cool, LLC,
manufacturer of world-class portable cooling units, for
industrial and commercial applications.
WARNINGS AND FESA TY LES RU
â–²
!
1. This unit is intended for indoor use. Any other use is
not recommended and may cause î™­re, electric hazard,
or injury to persons or property, and may void the
warranty.
2. Unplug the unit from power outlet when î™­lling and
reî™­lling water reservoir.
3. Unplug the unit from power outlet when moving the
unit. Use caution when moving the unit when there is
more than half full of water in the reservoir.
4. Unplug the unit from power outlet when cleaning or
servicing.
5. Do not use the unit in areas where gasoline, paint or
any other î™®ammable chemicals are stored.
6. Extreme caution should be taken when used near
children and the elderly. The unit should not be left
unattended for any extended period of time while in
operation.
7. Do not let children play with any packaging material.
8. Do not operate the unit with a damaged power cord.
9. Do not attempt to repair or adjust any electrical or
mechanical functions of the unit.
10. The PACKA53 unit should run on 110-120v 60Hz AC
only PACKA53-22050 on 220-240V 50Hz AC only , and
PACKA53-22060
on 220-240V 60Hz AC only.
11. Do not cover unit air inlet or air outlet openings.
12. This product is not intended for use in wet or damp
locations.
13. When not in use, drain the water from the reservoir
and store the unit in a dry location.
14. Do not run power cord under carpeting or cover with
rugs or runners. Arrange the cord away from areas
where it may be tripped over.
15. Do not use the unit with an extension cable.
16. Do not insert or allow objects to enter the air outlet
opening, as this may cause damage to the blower and
may void the warranty.
17. Use only fresh water to î™­ll the water reservoir. The
use of air fresheners or cleaners is not recommended
as it may damage the unit and void the warranty.
18. Drain the reservoir once every week to reduce calcium
saturation.
19. Do not use this appliance with any solid-state speed
control device.
20. If the unit is damaged or malfunctioning, discontinue
operation and refer to the trouble-shooting
section and/or contact a service technician via
1-888-999-6511.
Basic safety precautions should always be followed when using any electrical appliance.
Filling the Reservoir with Water
The water î™­ll door is located on the side
of the unit. Open the water î™­ll door and
pour water carefully into the reservoir.
Pay attention to the water level indicator
to avoid overî™­lling the unit. The capacity
of the reservoir is 15 liters/4 gallons.
You can also î™­ll water from the top
compartment.
Draining the Reservoir
Move the unit to a location where water
can be disposed of safely. Remove the
drain plug which is located at the back
of the unit to release water from the
reservoir. Once it is completely drained,
replace the drain plug. The unit is ready
to be î™­lled with fresh water.
USE AND OPER ION AT
â–²
!
CAUTION:
Unplug the unit
from power outlet prior
to moving or servicing, or
î™­lling or draining the water
reservoir. Use caution
when moving the unit if the
reservoir is more than half
full of water.
Side Water Fill
MOVE DIAL TOWARD MAXIMUM WATERFLOW
FOR ADDITIONAL COOLING IN CONDITIONS DRY
MOVE DIAL TOWARD MINIMUM WATERFLOW
FOR ADDITIONAL COOLING IN CONDITIONS HUMID
MIN
MAX
ADJUSTING WATER
FLOW VALVE
FOR OPTIMAL
COOLING
Wait 5 minutes between adjustments to monitor progress
Start with the water adjustment dial set in
the middle of minimum and maximum.
Dampen a clean cloth with water and use it on the exterior
of the unit to remove any dust or dirt.
Never use harsh detergents, solvents, and corrosive
cleaners to clean the unit. When not in use, drain
the water reservoir and store the unit in an area where it
is dry and out of sunlight.
MAINTENANCE
Regular draining, at least once each week, will decrease
the water mineral build up and extend the life of the
cooling pad. A damp cloth can be used to remove calcium
build-up inside and outside of the unit. When operating
the unit, turn Water Flow Regulator Knob to MIN position
to dry out the pad. The dust î™­lter/cover can be removed
easily and can be cleaned weekly. The inside of the water
reservoir can be cleaned once or twice in a season to
maintain air quality.
DEEP CLEAN
Remove the screw holding the dust î™­lter and slide out the
dust î™­lter. Remove the cooling pad. Clean the cooling pad
with fresh water and soft bristled brush to remove debris
and mineral build-up. Fill up the reservoir with fresh
water and drain. Repeat the procedure to remove debris
and mineral build-up from the reservoir.
â–²
!
WARNING: Unplug the unit from power
outlet prior to moving or servicing, or
î™­lling or draining the water reservoir.
CLEANING AND MAINTENANCE
USE AND OPER ION AT
POWER
1. Plug the cord to a power outlet. The amber power
icon will be illuminated with an audible sound. The
unit is in Standby mode.
2. Press POWER button to turn on the unit. Display will
illuminate and the POWER icon will turn green. When the
POWER button is pressed, the fan will start at MEDIUM speed
momentarily and switch to LOW speed. To turn off the unit
press the POWER button again.
SPEED
Press the SPEED button to select the desired fan speed.
The selected fan speed indicator LED light will light up.
Fan speed settings are 1( LOW) - 2 (MEDIUM) - 3 (HIGH).
SWING:
Press the SWING button to direct the air stream. The
vertical louvers will begin to move automatically from
side to side. The indicator LED will come on. To adjust
the vertical direction of air î™®ow, adjust the horizontal louvers
manually.
TIMER
The unit comes with a 8-hour timer function. To set
the timer, press the TIMER button to a desired operation time.
The selected time will be displayed. When the selected time
has elapsed, the unit will automatically shut off. In order to
cancel the TIMER function, press and hold the TIMER button
until the display shows 00.
DIM
Press DIM button once to reduce illumination from
control panel. Press DIM or any button to cancel the
DIM function.
COOL
To use the unit as an evaporative cooler, adjust the WATER
FLOW REGULATOR KNOB on the side panel. Water will be
pumped up to the water distributor compartment and start
wetting out the cellulose cooling pad in the rear of the unit.
After approximately three minutes, as the pad becomes
saturated, the air from the outlet should be cool. Turn the
knob to MIN position when ‘Cool’ function is not desired.
REMOTE CONTROL
Water Reservoir Capacity 15 Liters/4 gallons
Dimensions (cm) 75 H x 41 W x 39 D
Dimensions (inches) 33.75 H x 16.5 W x 15.5 D
Shipping Weight 12.0 kg/26 lbs.
ELECTRICAL
POWER – start or turn off the unit
SWING - automatic swing of louvers
DIM - display illumination dimmed
SPEED - Symbol 1 bar (Low)
Symbol 2 bars (Medium)
Symbol 3 bars (High)
TIMER - timer function up to 8 hours
TIMER CANCELED - cancels timer program
Model No. PACKA53
(110-120V 60Hz, 150W)
Model No. PACKA53-22050
(220-240V 50Hz, 150W)
Model No. PACKA53-22060
(220-240V 60Hz, 150W)


Produktspezifikationen

Marke: KuulAire
Kategorie: Klimaanlage
Modell: PACKA53

Brauchst du Hilfe?

Wenn Sie Hilfe mit KuulAire PACKA53 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage KuulAire

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-