König HC-EARTHERM60 Bedienungsanleitung

König Thermometer HC-EARTHERM60

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für König HC-EARTHERM60 (68 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/68
56
INFRERVE UŠNÍ TEPLOMĚR
44
INFRAPUNAKORVAKUUMEMITTARI
32
TERMÓMETRO DE OÍDO INFRARROJO
20
INFRAROOD OORTHERMOMETER
8
INFRAROT-OHRTHERMOMETER
62
TERMOMETRU DE URECHE
CU INFRAROŞU
50
INFRARÖD ÖRONTERMOMETER
38
INFRARÖS FÜLHŐMÉRŐ
26
TERMOMETRO AURICOLARE
A RAGGI INFRAROSSI
14
THERMOMÈTRE AURICULAIRE
À INFRAROUGE
INFRA-RED EAR THERMOMETER
HC-EARTHERM60
2
ENGLISH
Please read the instruction carefully before using
The ear thermometer is a device capable of achieving infra-red
temperature measurement when placed in the auditory canal of
a subject. It is a safe mean of measuring the human core body
temperature through the ear.
Specification:
The standard we adopted is EN12470-5:2003 Clinical thermometers
-- Part 5: Performance of infra-red ear thermometers (with maximum
device).
This device complies with the requirements of IEC 60601-1:1998, and
IEC 60601-1-2:2001.
Range of displayed temperature : 34.0°C ~44.0°C (93.F ~111.2°F)
Display L (L) when the temperature is under 34.0°C (93.2°F)
Display H (H) when the temperature is over 44.0°C(111.2°F)
Operating environment:
Temperature: 16°C ~3C
(60.8°F ~95.0°F )
Humidity: ≤ 80%RH
Storage and transport conditions:
Temperature: -25°C to
55°C (-13°F to 131°F)
Humidity: ≤ 85%RH
Temperature scale: 0.1°C (0.1°F )
Accuracy: ± 0.2°C (from
35.5°C to 42.0°C)
± 0.4°F (from
95.9°F to 107.6°F)
Display: liquid crystal display, 3½ digits
Temperature value: display the maximum temperature in measuring
process
Temperature unit: centigrade or Fahrenheit
Memory: Last 10 measurements
Low voltage warning: the LCD display shows: and then a beep sound
is heard
Probe lens
Scan button
LCD
On/recall button
Bat tery cover
3
Battery: 1x 3V Lithium battery (CR 2032)
Dimensions: 110x35x35 mm
Net weight: Approx. 37 g
Beeper sign: on/off, measuring finish and low voltage warning, etc.
Self-testing sequence: Press the 'on/recall' button to turn on the
thermometer and all of symbol (See Fig A) should be displayed on the
LCD in one second.
Cautions
1. Before measuring, the thermometer must be stabilized for at least
30 min. under operating conditions.
2. Please keep your ear canal clear, if not, the measuring result can be
inaccurate.
3. The symbol '?' on the LCD shows you can start the measurement.
4. Please don’t scratch the probe membrane, if you do, the thermometer
loses it‘s accuracy or can be broken completely.
5. If the thermometer does not respond when you press any button,
please take out and replace the batteries.
6. Please don’t use the thermometer if you have any symptons related
to otitis.
7. Type B equipment.


Produktspezifikationen

Marke: König
Kategorie: Thermometer
Modell: HC-EARTHERM60

Brauchst du Hilfe?