Kenmore 796.81073 Elite Bedienungsanleitung

Kenmore WƤschetrockner 796.81073 Elite

Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Kenmore 796.81073 Elite (35 Seiten) in der Kategorie WƤschetrockner. Dieser Bedienungsanleitung war fĆ¼r 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/35
Model/Modelo: 796.8107#, 796.9107#
Kenmore EliteĀ®
Steam Dryer
Secador con vapor
P/N MFL67731003
Sears Brand Management Corporation
Hoīƒ§man Estates, IL 60179 U.S.A.
www.kenmore.com
www.sears.com
Use & Care Guide
Manual de Uso y Cuidado
English / EspaƱol
# = color number, numero de color
Ā®
10
INSTALLATION INSTRUCTIONS
CONNECTING GAS DRYERS
GASī€ƒREQUIREMENTSī€ƒ(GASī€ƒMODELSī€ƒONLY)
To reduce the risk of īÆre,
electric shock, or injury to persons when using this
appliance, follow basic precautions, including
the following:
WARNING:
ā€¢ī€ƒGasī€ƒsupplyī€ƒrequirements:ī€ƒAsī€ƒshippedī€ƒfromī€ƒtheī€ƒ
factory,ī€ƒthisī€ƒdryerī€ƒisī€ƒconīÆguredī€ƒforī€ƒuseī€ƒwithī€ƒnaturalī€ƒ
gasī€ƒ(NG).ī€ƒItī€ƒcanī€ƒbeī€ƒconvertedī€ƒforī€ƒuseī€ƒwithī€ƒpropaneī€ƒ
(LP)ī€ƒgas.ī€ƒGasī€ƒpressureī€ƒmustī€ƒnotī€ƒexceedī€ƒ8ī€ƒinchesī€ƒ
waterī€ƒcolumnī€ƒforī€ƒ(NG),ī€ƒorī€ƒ13ī€ƒinchesī€ƒwaterī€ƒcolumnī€ƒforī€ƒ
(LP).
ā€¢ī€ƒAī€ƒqualiīÆedī€ƒserviceī€ƒorī€ƒgasī€ƒcompanyī€ƒtechnicianī€ƒmustī€ƒ
connect the dryer to the gas service. Failure to follow
these instructions can result in īÆre, explosion, or death.
ā€¢ī€ƒIsolate the dryer from the gas supply system by
closingī€ƒitsī€ƒindividualī€ƒmanualī€ƒshutoīƒ§ī€ƒvalveī€ƒduringī€ƒanyī€ƒ
pressure testing of the gas supply. Failure to do so can
result in īÆre, explosion, or death.
ā€¢ī€ƒSupplyī€ƒlineī€ƒrequirements:ī€ƒYourī€ƒlaundryī€ƒroomī€ƒmustī€ƒ
have a rigid gas supply line to your dryer. In the
Unitedī€ƒStates,ī€ƒanī€ƒindividualī€ƒmanualī€ƒshutoīƒ§ī€ƒvalveī€ƒ
MUSTī€ƒbeī€ƒinstalledī€ƒwithinī€ƒatī€ƒleastī€ƒ6ī€ƒft.ī€ƒ(1.8ī€ƒm)ī€ƒofī€ƒtheī€ƒ
dryer, in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code CSA
B149.1.ī€ƒAī€ƒā…›ī€ƒinchī€ƒNPTī€ƒpipeī€ƒplugī€ƒmustī€ƒbeī€ƒinstalled.ī€ƒ
Failure to do so can result in īÆre, explosion, or death.
ā€¢ī€ƒIf using a rigid pipe, the rigid pipe should be Ā½ inch
IPS. If acceptable under local codes and ordinances
andī€ƒwhenī€ƒacceptableī€ƒtoī€ƒyourī€ƒgasī€ƒsupplier,ī€ƒā…œī€ƒinchī€ƒ
approved tubing may be used where lengths are less
thanī€ƒ20ī€ƒft.ī€ƒ(6.1ī€ƒm).ī€ƒLargerī€ƒtubingī€ƒshouldī€ƒbeī€ƒusedī€ƒforī€ƒ
lengthsī€ƒinī€ƒexcessī€ƒofī€ƒ20ī€ƒft.ī€ƒ(6.1ī€ƒm). Failure to do so can
result in īÆre, explosion, or death.
ELECTRICAL REQUIREMENTS FOR
GAS MODELS ONLY
ā€¢ī€ƒDo not, under any circumstances, cut or remove the
thirdī€ƒ(ground)ī€ƒprongī€ƒfromī€ƒtheī€ƒpowerī€ƒcord. Failure
to follow this warning can result in īÆre, explosion, or
death.
ā€¢ī€ƒFor personal safety, this dryer must be properly
grounded. Failure to follow this warning can result in
īÆre, explosion, or death.
ā€¢ī€ƒTheī€ƒpowerī€ƒcordī€ƒofī€ƒthisī€ƒdryerī€ƒisī€ƒequippedī€ƒwithī€ƒ
aī€ƒ3-prongī€ƒ(grounding)ī€ƒplugī€ƒwhichī€ƒmatesī€ƒwithī€ƒaī€ƒ
standardī€ƒ3-prongī€ƒ(grounding)ī€ƒwallī€ƒoutletī€ƒtoī€ƒminimizeī€ƒ
the possibility of electric shock hazard from this
appliance. Failure to follow this warning can result in
īÆre, explosion, or death.
ā€¢ī€ƒThis dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker. Failure to follow this warning can result
in īÆre, explosion, or death.
ā€¢ī€ƒWhere a standard 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet. Failure to follow this warning can result in
īÆre, explosion, or death.
ā€¢ī€ƒConnect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in īÆre,
explosion, or death.
ā€¢ī€ƒTo prevent contamination of the gas valve, purge the
gas supply of air and sediment before connecting
the gas supply to the dryer. Before tightening the
connection between the gas supply and the dryer,
purge remaining air until the odor of gas is detected.
Failure to do so can result in īÆre, explosion, or death.
ā€¢ī€ƒDOī€ƒNOTī€ƒuseī€ƒanī€ƒopenī€ƒī°ameī€ƒtoī€ƒinspectī€ƒforī€ƒgasī€ƒleaks.ī€ƒ
Useī€ƒaī€ƒnoncorrosiveī€ƒleakī€ƒdetectionī€ƒī°uid.ī€ƒFailure to do
so can result in īÆre, explosion, or death.
ā€¢ī€ƒUseī€ƒonlyī€ƒaī€ƒnewī€ƒAGA-ī€ƒorī€ƒCSA-certiīÆedī€ƒgasī€ƒsupplyī€ƒ
lineī€ƒwithī€ƒī°exibleī€ƒstainlessī€ƒsteelī€ƒconnectors. Failure to
do so can result in īÆre, explosion, or death.
ā€¢ī€ƒSecurely tighten all gas connections. Failure to do so
can result in īÆre, explosion, or death.
ā€¢ī€ƒUseī€ƒTeī°onī€ƒtapeī€ƒorī€ƒaī€ƒpipe-jointī€ƒcompoundī€ƒthatī€ƒisī€ƒ
insolubleī€ƒinī€ƒpropaneī€ƒ(LP)ī€ƒgasī€ƒonī€ƒallī€ƒpipeī€ƒthreads.
Failure to do so can result in īÆre, explosion,
or death.
ā€¢ī€ƒDO NOT attempt any disassembly of the dryer;
disassemblyī€ƒrequiresī€ƒtheī€ƒattentionī€ƒandī€ƒtoolsī€ƒofī€ƒ
anī€ƒauthorizedī€ƒandī€ƒqualiīÆedī€ƒserviceī€ƒtechnicianī€ƒorī€ƒ
company. Failure to follow this warning can result in īÆre,
explosion, or death.
3-prong
grounding
plug
3-prong
grounding
type wall
receptacle
Ensure proper
ground exists
before use.
11
To reduce the risk of īÆre,
electric shock, or injury to persons when using this
appliance, follow basic precautions, including
the following:
ā€¢ī€ƒInstallation and service must be performed by a
qualiīÆedī€ƒinstaller,ī€ƒserviceī€ƒagency,ī€ƒorī€ƒtheī€ƒgasī€ƒsupplier.ī€ƒ
Failure to do so can result in īÆre, explosion, or death.
ā€¢ī€ƒUseī€ƒonlyī€ƒaī€ƒnewī€ƒstainlessī€ƒsteelī€ƒī°exibleī€ƒconnectorī€ƒandī€ƒ
aī€ƒnewī€ƒAGA-certiīÆedī€ƒconnector.ī€ƒFailure to do so can
result in īÆre, explosion, or death.
ā€¢ī€ƒAī€ƒgasī€ƒshutoīƒ§ī€ƒvalveī€ƒmustī€ƒbeī€ƒinstalledī€ƒwithinī€ƒ6ī€ƒft.ī€ƒ
(1.8ī€ƒm)ī€ƒofī€ƒtheī€ƒdryer. Failure to do so can result in īÆre,
explosion, or death.
ā€¢ī€ƒTheī€ƒdryerī€ƒisī€ƒconīÆguredī€ƒforī€ƒnaturalī€ƒgasī€ƒwhenī€ƒ
shipped from the factory. Make sure that the dryer
isī€ƒequippedī€ƒwithī€ƒtheī€ƒcorrectī€ƒburnerī€ƒnozzleī€ƒforī€ƒtheī€ƒ
typeī€ƒofī€ƒgasī€ƒbeingī€ƒusedī€ƒ(naturalī€ƒgasī€ƒorī€ƒpropaneī€ƒgas).
Failure to do so can result in īÆre, explosion, or death.
Connectingī€ƒtheī€ƒGasī€ƒSupply
NOTE: This dryer is conīÆgured from the factory set for
natural gas (NG). If dryer is to be used with propane
(LP) gas, it must be converted by a qualiīÆed
service technician.
Make sure that the gas supply to the laundry room is
turned OFF and the dryer is unplugged. ConīÆrm that
the type of gas available in your laundry room is
appropriate for the dryer.
Remove the shipping cap from the gas īÆtting at the
back of the dryer. Be careful not to damage the
threads of the gas connector when removing the
shipping cap.
Connect the dryer to your laundry roomā€™s gas supply
using a new ī°exible stainless steel connector with a ā…œ
inches NPT īÆtting.
NOTE: DO NOT use old connectors.
Securely tighten all connections between the dryer
and your laundry roomā€™s gas supply.
Turn on the gas supply.
Check all pipe connections (both internal and external)
for gas leaks with a noncorrosive leak-detection ī°uid.
Proceed to Venting the Dryer.
High-Altitudeī€ƒInstallations
The BTU rating of this dryer is AGA-certiīÆed for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation
above 10,000 feet, it must be derated by a qualiīÆed
technician or gas supplier.
ā€¢ī€ƒIfī€ƒnecessary,ī€ƒtheī€ƒcorrectī€ƒnozzleī€ƒ(forī€ƒtheī€ƒLPī€ƒnozzleī€ƒkit,ī€ƒ
orderī€ƒpartī€ƒnumberī€ƒ383EEL3002D)ī€ƒshouldī€ƒbeī€ƒinstalledī€ƒ
byī€ƒaī€ƒqualiīÆedī€ƒtechnicianī€ƒandī€ƒtheī€ƒchangeī€ƒshouldī€ƒbeī€ƒ
noted on the dryer. Failure to do so can result in īÆre,
explosion, or death.
ā€¢ī€ƒAll connections must be in accordance with local
codes and regulations. Failure to do so can result in
īÆre, explosion, or death.
ā€¢ī€ƒGas dryers MUST exhaust to the outdoors. Failure to do
so can result in īÆre, explosion, or death.
WARNING:
1
2
3
4
5
6
7
INSTALLATION INSTRUCTIONS
3/8" NP T Gas
Connection
Gas Supply
Shuto alveff V
AGA/CSA-Certiļ¬ed
Stainless Steel
Flexible Connector
1/8" NP T Pipe Plug
ā…œ in. NPT Gas
Connection
ā…› in. NPT Pipe Plug
AGA/CSA-CertiīÆed
Stainless Steel Flexible
Connector
Gas Supply
Shutoīƒ¬ Valve
CONNECTINGī€ƒGASī€ƒDRYERSī€ƒ(continued)


Produktspezifikationen

Marke: Kenmore
Kategorie: WƤschetrockner
Modell: 796.81073 Elite

Brauchst du Hilfe?

Wenn Sie Hilfe mit Kenmore 796.81073 Elite benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung WƤschetrockner Kenmore

Bedienungsanleitung WƤschetrockner

Neueste Bedienungsanleitung fĆ¼r -Kategorien-