Kelvinator KWH62HRE Bedienungsanleitung
Kelvinator
Klimaanlagen
KWH62HRE
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Kelvinator KWH62HRE (16 Seiten) in der Kategorie Klimaanlagen. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/16
Window Wall (Electronic)
Room Air Conditioner
User Manual
KWH20CRE, KWH20HRE, KWH26CRE
KWH26HRE, KWH39CRE, KWH39HRE
KWH53CRE, KWH53HRE, KWH62CRE
KWH62HRE
Refrigerant R32
2 Contents Kelvinator Air Conditioning
Congratulations and thank you for choosing our Electric
Window Wall room air conditioner. We are sure you will find
your new air conditioner a pleasure to use. Before you use
the air conditioner, we recommend that you read through
the entire user manual, which provides the description of
the air conditioner and its functions.
To avoid the risks that are always present when you use an
electrical appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not
damaged. If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.
environmental tip
Information on disposal for users
• Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate
collection containers.
• If you wish to discard this air conditioner, please contact
your local authorities and ask for the correct method
of disposal.
• This product contains refrigerant which must be
reclaimed by a licensed refrigeration mechanic before the
product can be disposed of.
refrigerant warning
This unit uses refrigerant R32 and must be disposed of
by a licensed refrigeration mechanic with knowledge of
appropriate gas reclamation methods.
caution
• The air conditioner is not intended for use by young
children or infirmed persons without supervision.
• Young children should be supervised to ensure that they
do not play with the air conditioner.
• Contact an authorised installer for installation of this unit.
• Contact an authorised service technician for repair or
maintenance of this unit.
• If the power cord is to be replaced, replacement work
must be performed by authorised personnel only.
• Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
Safety precautions ..................................................................... 3
Prior to operation.............................................................. 4
Unit parts identification ............................................................ 5
Operating instructions ..............................................................5
Maintenance ...................................................................... 7
Installation instructions ..........................................................10
Troubleshooting .......................................................................12
Congratulations Contents
wa inrn g
Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by the manufacturer.
Do not store the appliance in a room with continuously
operating ignition sources (for example open flames,
an operating electric heater or an operating gas
appliance with a continuously lit pilot flame).
Do not pierce or burn.
Be aware that the refrigerant may be odourless.
Connect with power properly.
Otherwise, it may cause electric shock or fire due to
excess heat generation.
Do not operate or stop the unit by switching on or
off the power.
It may cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire.
If the power cord is damaged, it must be replaced by
the manufacturer or an authorised service centre or a
similarly qualified person in order to avoid a hazard.
Do not modify power cord length or share the outlet
with other appliances.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not direct airflow at room occupants only.
This could damage your health.
Always ensure effective earthing.
No earthing may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Always install circuit breaker and a dedicated
power circuit.
No installation may cause fire and electric shock.
Disconnect the power if strange sounds, smell,
or smoke comes from the unit.
It may cause fire and electric shock.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not open the unit during operation.
It may cause electric shock.
Keep firearms away.
It may cause a fire.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Do not use the power cord near flammable gas or
combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Ventilate room before operating air conditioner if
there is a gas leakage from another appliance.
It may cause explosion, fire and burns.
Do not disassemble or modify unit.
It may cause failure and electric shock.
Safety precautions
Kelvinator Air Conditioning Important safety instructions 3
caution
• Contact an authorised service technician for repair or
maintenance of this unit.
• Contact a licensed installer for installation of this unit.
• The air conditioner is not intended for use by young
children or infirmed persons without supervision.
• Young children should be supervised to ensure that they
do not play with the air conditioner.
• This air conditioner must be installed in accordance with
AS/NZS 3000:2000 and your electricity suppliers rules.
• There are local council rules regarding maximum
allowable noise levels emitted by air conditioners.
• If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
• Installation work must be performed in accordance with
the national wiring standards by authorised personnel
only. Wrong connection can cause overheating or fire.
Inside this manual you will find many helpful hints on how to
use and maintain your air conditioner properly.
Just a little preventative care on your part can save you
a great deal of time and money over the life of your air
conditioner. You'll nd many answers to common problems
in the chart of troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need to call for service.
Meanings of symbols used in this manual are shown below:
wa inrn g
This symbol indicates information concerning your
personal safety
caution
This symbol indicates information on how to avoid
damaging the appliance
ti and fops in rmat nio
This symbol indicates tips and information about
use of the appliance
environmental tip
This symbol indicates tips and information about
economical and ecological use of the appliance
This symbol indicates never to do this
This symbol indicates always do this
Produktspezifikationen
Marke: | Kelvinator |
Kategorie: | Klimaanlagen |
Modell: | KWH62HRE |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Kelvinator KWH62HRE benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Klimaanlagen Kelvinator
14 Oktober 2024
12 Oktober 2024
9 Juli 2024
6 Juli 2024
5 Juli 2024
Bedienungsanleitung Klimaanlagen
- Klimaanlagen Samsung
- Klimaanlagen Tristar
- Klimaanlagen Nedis
- Klimaanlagen Panasonic
- Klimaanlagen LG
- Klimaanlagen Adler
- Klimaanlagen Electrolux
- Klimaanlagen Gorenje
- Klimaanlagen Klarstein
- Klimaanlagen Whirlpool
- Klimaanlagen Alaska
- Klimaanlagen Melissa
- Klimaanlagen Vox
- Klimaanlagen Telefunken
- Klimaanlagen BEKO
- Klimaanlagen Campomatic
- Klimaanlagen Heinner
- Klimaanlagen Inventum
- Klimaanlagen Sharp
- Klimaanlagen Mitsubishi
- Klimaanlagen GE
- Klimaanlagen Haier
- Klimaanlagen Hisense
- Klimaanlagen Hotpoint-Ariston
- Klimaanlagen Midea
- Klimaanlagen Frigidaire
- Klimaanlagen Svan
- Klimaanlagen Eurom
- Klimaanlagen Hitachi
- Klimaanlagen Toshiba
- Klimaanlagen Vaillant
- Klimaanlagen Inventor
- Klimaanlagen Qlima
- Klimaanlagen Haverland
- Klimaanlagen Zibro
- Klimaanlagen Elba
- Klimaanlagen White Knight
- Klimaanlagen Saunier Duval
- Klimaanlagen Dimplex
- Klimaanlagen Diamant
- Klimaanlagen Fujitsu
- Klimaanlagen Toyotomi
- Klimaanlagen Amana
- Klimaanlagen Royal Sovereign
- Klimaanlagen Rasonic
- Klimaanlagen Alpatec
- Klimaanlagen AlpicAir
- Klimaanlagen Coolix
- Klimaanlagen Gree
- Klimaanlagen Olimpia Splendid
- Klimaanlagen SereneLife
- Klimaanlagen Danby
- Klimaanlagen RCA
- Klimaanlagen Daikin
- Klimaanlagen Daitsu
- Klimaanlagen Fuave
- Klimaanlagen Jocel
- Klimaanlagen Lloyd
- Klimaanlagen Maiko
- Klimaanlagen Maxicool
- Klimaanlagen Tarrington House
- Klimaanlagen Tatung
- Klimaanlagen Western
- Klimaanlagen Whynter
- Klimaanlagen Becken
- Klimaanlagen Godrej
- Klimaanlagen Equation
- Klimaanlagen Mabe
- Klimaanlagen Commercial Cool
- Klimaanlagen Alhafidh
- Klimaanlagen Admiral
- Klimaanlagen National
- Klimaanlagen Airmaster
- Klimaanlagen Taurus-Alpatec
- Klimaanlagen Evapolar
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
15 Oktober 2024
14 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024