JUNG ATR231PL Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JUNG ATR231PL (5 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
Room temperature controller
26.06.20201 / 50024091005
Room temperature controller
Ref.-no.: TR .. 231 ..
TR .. 241 ..
TR .. 236 ..
TR .. 246 ..
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, îš¿re or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
A relative air humidity of max. 95% may not be exceeded. Avoid any moisture condensation.
These instructions are an integral part of the product, and must remain with the end customer.
2 Structure of the device
Fig. 1: Geräteaufbau
(1) Insert
(2) Frame
(3) Cover
(4) Rocker
(5) Screw
(6) Setting knob
3 Function
Intended purpose
The room temperature controller is used to regulate the temperature in closed rooms such as ats, schools, function
suites, workshops, etc.
Product characteristics
Neutral conductor required
TR 231 U / TR 241 U:
- Separate terminal for temperature reduction of 5 K (e.g. during night time)
- ON/OFF switch with status LED
- When set temperature is reached the contact opens up.
TR 236 U / TR 246 U:
- No OFF-position
- Without switch and control LED
- When set temperature is reached the NO/NC contact switches over.
2
5
3
4
1
6
GB
Room temperature controller
26.06.20202 / 50024091005
4 Information for electrically skilled persons
Installation and electrical connection
DANGER
Electric shock from touching live parts in the installation environment.
An electric shock can be fatal.
Before working on the device, disconnect the power and cover live parts in the area.
- Mount the room temperature controller on an internal wall opposite the heat source if possible.
- Do not mount the room temperature controller on outside walls.
- Avoid draughts from windows and doors.
- Ensure that the normal air circulation in the room reaches the controller without any obstacles.
- External heat sources inuence the accuracy of the controller. Avoid direct sunlight and do not place heat-emitting
devices in the vicinity of the room temperature controller (heaters, lamps, etc.).
- Dimmers also generate heat.
If a controller is installed in a common switch frame with a dimmer, the distance between them should be as great
as possible. When arranging them vertically, the controller must be installed underneath the dimmer.
Connection
Fig. 2: TR 231 U
Fig. 3: TR 241 U
Room temperature controller
26.06.20203 / 50024091005
Fig. 4: TR 236 U
Fig. 5: TR 246 U
• Carry out the electrical connection according to the respective wiring diagram.
iEnsure that the neutral conductor N is connected to terminal N. Considerable uctuations in temperature may
otherwise occur.
Conductor cross-section: 1 to 2.5 mm² solid conductor
Symbols used in the wiring diagram
L = L conductor
N = N-conductor
AC1 = 24 V power supply
AC2
= Connection for clock signal to reduce temperature
= Heating
= Cooling
RF = Resistor for thermal feedback
TA = Resistor for night reduction of room temperature
Installation
• Mount room temperature controller in a switch box in accordance with DIN 49073.
Mounting height: approx. 1.5 m above the oor
• Clip the rocker (4) on the switch in the ush insert. (g. 1)
• Place the center plate together with the frame on the ush insert. The center plate must snap in place in the top
left of the housing base.
• Tighten the screw (5). (g. 1)
• Clip on the setting knob (6). (g. 1)


Produktspezifikationen

Marke: JUNG
Kategorie: Nicht kategorisiert
Modell: ATR231PL

Brauchst du Hilfe?

Wenn Sie Hilfe mit JUNG ATR231PL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert JUNG

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-