JUNG 1202URE Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JUNG 1202URE (6 Seiten) in der Kategorie Schalten. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/6
Relay switch insert 2-channel
Light Management
Relay switch insert 2-channel
Art.-No.: 1202 URE
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
Danger of electric shock on the SELV/PELV installation. Not suitable for switching SELV/
PELV voltages.
Danger of electric shock. Do not operate the insert without a cover.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
picture 1
(1) Flush-mounted insert
(2) Frame
(3) Pushbutton cover
(4) Adjuster for run-on time of output HLK
(5) Connection terminals for mains voltage and output Kanal 1
(6) Connection terminals for output for HVAC HLK
3 Function
Intended use
- Output for switching light Kanal 1
- Output for switching light, fans, air conditioners, thermostats and motors HLK
1/6
32541323
J:0082541323 30.07.2010
- Operation with suitable cover
- Installation in appliance box to DIN 49073 acc.
Product characteristics
- Output with potential-free NO contact for switching a second electric circuit, not SELV HLK
or PELV
- Switch-on delay of output can be switched off HLK
- Run-on time of output adjustable HLK
- Connection of extensions possible
Function with motion detector or presence detector cover
Output Kanal 1
- Output is switched on if motions are detected and the brightness is below the threshold set
on the cover.
- Output remains switched on as long as motions are detected.
- Output is switched off if no more motions are detected and the run-on time set on the cover
has elapsed.
Output HLK
- Switch-on delay switched on: output is switched on independently of the brightness after
3 minutes if additional motions are detected approx. 2.5 to 3 minutes after the initial
detection.
- Switch-on delay switched off: output is switched on independently of brightness if motion is
detected.
- Output remains switched on as long as motions are detected.
- Output is switched off if no more motions are detected and the run-on time set on the insert
has elapsed.
Behaviour after a mains voltage failure
- Less than 0.2 seconds: switching state is retained
- longer than 0.2 seconds: both channels switch off. The behaviour after mains voltage
return depends on the cover used (see instructions for the cover).
4 Operation
Switching on with pushbutton cover (see Accessories)
Operation on the main device, 2-wire extension or on the installation button is identical.
i Extension operation is only possible if there is a cover fitted on the main device.
Outputs are switched off.
o Press the button.
Output switches on. Kanal 1
When the switch-on delay for output is switched off, output switches on directly. HLK HLK
When the switch-on delay for output is switched on, output switches on with a HLK HLK
time delay, if output is switched on for longer than 3 minutes. Kanal 1
Switching off with pushbutton cover (see Accessories)
Outputs are switched on.
o Press the button.
Output switches off. Kanal 1
Output switches off after the run-on time set on the insert elapses. The run-on time HLK
begins as soon as output has switched off. Kanal 1
Switching on in combination with motion detector or presence detector
Operation is performed with a 2-wire extension or an installation button. Only an overview of the
behaviour is provided here. For additional information, please refer to the instructions for the
cover in question. Operation with an extension is only possible is there is a cover fitted on the
main device.
Outputs are switched off.
2/6
32541323
J:0082541323 30.07.2010
Light Management
Relay switch insert 2-channel
o Press extension.
Output switches on. Kanal 1
When the switch-on delay for output is switched off, output switches on directly. HLK HLK
When the switch-on delay for output is switched on, output switches on after a HLK HLK
time delay of 3 minutes, if no additional motions are detected for approx. 2.5 to 3 minutes
after the extension is operated.
Switching off in combination with motion detector or presence detector
i Combination with motion detector: outputs cannot be switched off.
i Combination with presence detector: the output cannot be switched off. HLK
Outputs are switched on.
o Press extension.
Output switches off for 3 minutes. Any motions that are detected extend the time. Kanal 1
During these 3 minutes output can only be switched on again via the extension. Kanal 1
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Connecting and mounting the insert
picture 2: Connection diagram with optional extensions
(1) Flush-mounted insert
(7) Extension insert, 2-wire
(8) Extension insert, 3-wire
(9) Installation button, NO contact
i Outputs and are not protected internally. For device protection, connect a Kanal 1 HLK
10 A miniature circuit breaker upstream.
3/6
32541323
J:0082541323 30.07.2010
Light Management
Relay switch insert 2-channel
Produktspezifikationen
Marke: | JUNG |
Kategorie: | Schalten |
Modell: | 1202URE |
Brauchst du Hilfe?
Wenn Sie Hilfe mit JUNG 1202URE benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalten JUNG
20 September 2024
3 September 2024
2 September 2024
1 September 2024
28 August 2024
28 August 2024
28 August 2024
23 August 2024
23 August 2024
13 August 2024
Bedienungsanleitung Schalten
- Schalten Asus
- Schalten Belkin
- Schalten Hama
- Schalten HP
- Schalten LogiLink
- Schalten Manhattan
- Schalten Nedis
- Schalten Philips
- Schalten SilverCrest
- Schalten Panasonic
- Schalten Brennenstuhl
- Schalten Clas Ohlson
- Schalten Cotech
- Schalten Profile
- Schalten ZyXEL
- Schalten Bosch
- Schalten Yamaha
- Schalten Powerfix
- Schalten CSL
- Schalten Eminent
- Schalten Linksys
- Schalten Netgear
- Schalten König
- Schalten PCE
- Schalten Renkforce
- Schalten Trotec
- Schalten Schneider
- Schalten Rex
- Schalten Kaiser
- Schalten Vivanco
- Schalten Abus
- Schalten Elro
- Schalten Smartwares
- Schalten Tesla
- Schalten Perel
- Schalten Nexa
- Schalten Tork
- Schalten GEV
- Schalten Goobay
- Schalten Lindy
- Schalten Tripp Lite
- Schalten Ansmann
- Schalten Mercusys
- Schalten Marmitek
- Schalten Honeywell
- Schalten TRENDnet
- Schalten TP-Link
- Schalten Kathrein
- Schalten Flamingo
- Schalten Alcatel
- Schalten Tiptel
- Schalten Black Box
- Schalten Alpine
- Schalten Techly
- Schalten Ebode
- Schalten Theben
- Schalten Vacmaster
- Schalten GAO
- Schalten Hager
- Schalten Behringer
- Schalten Omnitronic
- Schalten Monoprice
- Schalten Ecler
- Schalten Monacor
- Schalten Huawei
- Schalten Victron Energy
- Schalten Ei Electronics
- Schalten Edimax
- Schalten Totolink
- Schalten D-Link
- Schalten Sylvania
- Schalten Audiovox
- Schalten B-Tech
- Schalten QNAP
- Schalten SPC
- Schalten Speaka
- Schalten Digitus
- Schalten Sygonix
- Schalten DataVideo
- Schalten Lancom
- Schalten LevelOne
- Schalten Merten
- Schalten APC
- Schalten Eberle
- Schalten Cisco
- Schalten Delta Dore
- Schalten Grässlin
- Schalten Tenda
- Schalten CyberPower
- Schalten Boss
- Schalten IFM
- Schalten Intertechno
- Schalten Elation
- Schalten Ubiquiti Networks
- Schalten Kramer
- Schalten Aeon Labs
- Schalten Intellinet
- Schalten Eaton
- Schalten AV:link
- Schalten Hikvision
- Schalten Vemer
- Schalten PreSonus
- Schalten Planet
- Schalten EnGenius
- Schalten Finder
- Schalten Mikrotik
- Schalten Shimano
- Schalten Homematic IP
- Schalten Berker
- Schalten Dormakaba
- Schalten Emerson
- Schalten Generac
- Schalten Intermatic
- Schalten KlikaanKlikuit
- Schalten Mercury
- Schalten Paladin
- Schalten Provision ISR
- Schalten Robbe
- Schalten SEC24
- Schalten Steren
- Schalten Suevia
- Schalten AMX
- Schalten Triax
- Schalten WHALE
- Schalten Vimar
- Schalten Cudy
- Schalten Siig
- Schalten Electro Harmonix
- Schalten RGBlink
- Schalten Iogear
- Schalten StarTech.com
- Schalten Smart-AVI
- Schalten Dahua Technology
- Schalten PAC
- Schalten Gefen
- Schalten Avocent
- Schalten Legrand
- Schalten Atlantis Land
- Schalten CYP
- Schalten H-Tronic
- Schalten ATen
- Schalten Axing
- Schalten KanexPro
- Schalten SmartAVI
- Schalten Advantech
- Schalten Kraus & Naimer
- Schalten Chacon
- Schalten Juniper
- Schalten Fibaro
- Schalten Phoenix Contact
- Schalten Audac
- Schalten OSD Audio
- Schalten Wentronic
- Schalten SunBriteTV
- Schalten BZBGear
- Schalten Crestron
- Schalten Kemo
- Schalten ORNO
- Schalten Extron
- Schalten Atlona
- Schalten Equip
- Schalten Heitronic
- Schalten Hamlet
- Schalten STI
- Schalten Matrox
- Schalten Blustream
- Schalten Vivolink
- Schalten Mach Power
- Schalten Ernitec
- Schalten Cambium Networks
- Schalten ConnectPro
- Schalten Micro Connect
- Schalten Intelix
- Schalten ICasa
- Schalten Maclean Energy
- Schalten Cooking Performance Group
- Schalten Flic
- Schalten Liberty
- Schalten Noark
- Schalten 2USB
- Schalten KVM-TEC
- Schalten Setti+
- Schalten PureLink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
12 Oktober 2024
11 Oktober 2024
8 Oktober 2024
8 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024
3 Oktober 2024