Operation & Installation Instructions
Kimberley Mk3 Freestanding
Please keep these instructions for future reference.Rev* 231537
Kimberley Mk3 Freestanding 12
WARRANTY
Heating
A division of A.F. Gason Pty. Ltd.
1. Subject to clauses 2 & 3 of this Warranty, A.F. Gason Pty Ltd ACN 004 667 556 (Gason warrants the follow components of its heaters against defects in workmanship
and/or materials for the following periods from the date of purchase:
a) the rebox for ten years;
b) the paint nish for a period of twelve months if the Purchaser has followed the instructions provided by Gason in the Operation and Installation Instructions manual; and
c) all other components for twelve months execpt the glass, re brick lining or ba e plate if, in the opinion of Gason, these items have been damaged by impact.
2. This extended warranty does not apply;
a) if the heater is purchased from a person who has not been authorised by Gason to sell its products;
b) if, in the opinion of Gason, the heater or any other component has been subject to abuse, misuse, alteration, modi cation or has not been installed, operated or maintained in
accordance with the instructions provided by Gason; or,
c) to owners other then the original Purchaser.
3. If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this Warranty, please contact an authorised Gason service
centre to arrange for an assessment.
4. If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretio n:
a) replace the heater;
b) repair or replace speci c components of the heater; or
c) provide a full refund.
5. Parts replaced under warranty are warranted for the balance of their original warranty period.
6. If, at the discretion of Gason, the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this
Warranty must pay all costs associated with:
a) returning the heater; and
b) the delivery or collection of any new or repaired heater.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or r eplaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
Any bene ts you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under a law in relation to the heater to which
these warranties relate.
These warranties are given by:
A.F. Gason Pty. Ltd.
Blake Street
Ararat VIC 3377
Please contact us if you have any queries on:
Phone: 03 53522151
or email us via the “Contact Us” section of our website: www.g ason.com.au
Kimberley Mk3 Freestanding 2 Kimberley Mk3 Freestanding 11
PAGE INTENTIONALLY BLANK
T
Read and follow these instructions carefully before installing and
u
sing this appliance
S
AVE THESE INSTRUCTIONS
WARNING
!
WARNING
!
Safety Warnings
•
A ue re with resulting damage may occur if the appliance is not installed,
operated and maintained as per this booklet.
• Never place combustible materials such as wood, paper or furniture near the
appliance.
• This appliance is designed to burn dry hardwood. Do not burn rubbish,
driftwood, ammable liquids or any substance containing salts or corrosives.
• This appliance must not be installed and operated in an area where kerosene,
petrol, paint thinner or other ammable liquid is used or stored.
• The ue system must be inspected and cleaned annually or sooner if required.
Failure to do so could result in an excessive build up of creosote which may
result in a ue re which may damage the ue or cause damage to your home.
• The surface of the appliance becomes hot during operation. Do not touch the
surface of this appliance. Keep children away from this appliance during
operation. Do not allow anyone to operate this appliance who is not familiar
with this instruction booklet.
WARNING
!
Paint Curing and Care
Your heater is coated with the best available heat resistant paint. Even though
t
he paint has been baked after application, it may require further temperature
c
uring. It may, if you over re the heater on its rst re, discolour. For your rst
t
wo or three rings, never exceed the medium air setting and always have the fan
o
n when above low burn. Do not wipe the heater while the paint is curing. After
t
he paint has cured the only maintenance required to maintain the heater’s nish
i
s to wipe it with a soft cloth. Do not use any commercial cleaners or solvents on
t
he paint nish.
W
e are proud of the presentation of our products. If at any time you need to
f
reshen up the paint, your local dealer has touch up paint available for purchase.
Y
ou may even change the colour of your heater if you wish.
If you have any enquiries, please contact the dealer from whom you purchased your heater:
P
LEASE COMPLETE:
D
ealer Name
D
ealer Address
Phone:
P
lease attach your original purchase dockets to this booklet for future reference.
Kimberley Mk3 Freestanding 10 Kimberley Mk3 Freestanding 3
Installation
WARNING
!
Installation
THE STALLATION OF THIS APPL E ST BE RRIED T AS PER THISIN IANC MU CA OU
MANUAL AND THE F E UFA R S S FICATIONS. LU MAN CTU ER’ PECI
WE D THAT YOU E A QURECOMMEN US ALI IE INF D STALLER TO CARRY OUT
THE STIN ALLATION.
If u have any other en ies, ase cont t the ler from whom youyo quir ple ac dea
pu sercha d ur er.yo heat
THIS APPL E IANC WEIG CES 15 KILHS IN EX S OF 0 OG MS. EXTR E RERA EM CA
SHO D BE TA N WHEN ING THE APPL E.UL KE HANDL IANC
Troubleshooting (continued)
• Smoke entering the room from the rebox when the door is open may be caused by
• Insu cient length of ue ( ue to be 4500mm minimum underneath the base of heater to
underside of cowl)
Increase height of ue
• Flue downdraught
Consult dealer or increase height of ue.
• Creosote buildup in ue
Remove cowl and clean ue as per cleaning instructions. Check moisture content of wood.
• Excessive ash build up
Some woods will give large amounts of ash despite how you run the he ater. Others will give you very little.
Use the wood which is most convenient for you as long as it is dry. After a period of time you will get to
know when to empty your unit. Bark will give you excessive ash. Try not to burn it.
If you are burning wood that gives you charcoal, you may nd that after running the heater say for 8 hours
at maximum burn rate, the charcoal builds up excessively. Overnight burn will reduce this charcoal back to
a ne ash. If you are not ready to shut down for overnight burn when you next fuel the stove, load the
stove with only one piece of wood and lay it across the rebox on top of the charcoal. Open the air control
wide open and you will nd the charcoal will burn down with the one piece of wood. Repeat the process
until the ash level is signi cantly reduced.
t is important you understand these installation instructions and minimum clearances to combustible material
efore selecting a position for your Jindara Kimberley to ensure safe and correct installation is achieved.
nstallation Permit
epending on your local authority requirements, a permit may be required for the installation of your heater. It i
our responsibility to arrange the same.
learances
ll dimensions used in this document are in millimetres and are minimum unless otherwise stated. Thes
imensions state the minimum distance the Jindara Kimberley can be placed in relation to any combustibl
aterials – plaster, wallpaper, timber, MDF etc.
n the instance your Jindara Kimberley is surrounded by non-combustible materials – brick, stone, concrete
ement sheet, villaboard or similar, wall clearances can be reduced to 100mm. A 100mm clearance is required t
nsure room air can circulate around the wood heater during operation.
he Jindara Kimberley freestanding heater conforms to AS/NZS 2918:2001 when positioned in relation to
ombustible surfaces as shown in the graphic on the following page.
or additional clearance details, or to access the Jinidara Kimberely Freestanding thermal clearance test report –
CMG-15-066- please contact the Jindara dealer from whom you purchased your heater.
earth Requirements
f the Jindara Kimberley will be installed onto a non-combustible oor such as a brick, stone or a concrete slab with
iles etc. which are at least 9mm thick, and extends at least 300mm in front of the appliance base, a hearth or oor
rotector may not be required.
f the Jindara Kimberley is to be installed onto a combustible oor, a minimum 9mm cement sheet or similar non-
ombustible hearth or oor protector must be placed on top of the combustible oor. At a minimum, the oor
rotector must extend 300mm in front of the appliance base. The protector must be at least 940mm wide and
40mm deep. If desirable, the oor protector can extend to 940mm deep to meet skirting boards or walls at the
ear of the appliance when installed as per the rear wall clearances.
or details please see the pictorial on the next page.


Produktspezifikationen

Marke: Jindara
Kategorie: Heizung
Modell: Kimberley Mk3 Freestanding

Brauchst du Hilfe?

Wenn Sie Hilfe mit Jindara Kimberley Mk3 Freestanding benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Jindara

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung fĂĽr -Kategorien-