Jindara Franklin Bedienungsanleitung

Jindara Heizung Franklin

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Jindara Franklin (8 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 28 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
Franklin Freestanding
GPN: 236793
Rev A
Franklin Freestanding
Operation & Installation Instructions
Please keep these instructions for future reference.
15
1. Subject to clauses 2 & 3 of this warranty, A.F. Gason Pty Ltd ACN 004 667 556 warrants the following components of its heaters against defect in
workmanship and/or materials for the following periods from the date of purchase:
a. the rebox for ten years;
b. the paint nish for a period of 12 months if the purchaser has followed the instructions provided by Gason in the Operation and Installation
Instructions manual; and
c. all other components for 12 months except the glass, re brick lining or bae plates if, in the opinion of Gason, these items have been damaged by
impact.
2. this extended warranty does not apply;
a. if the heater has been purchased from a person who has not been authorised by Gason to sell its products;
b. if, in the opinion of Gason, the heater or any other component has been subject to abuse, misuse, alteration, modication or has not been installed,
operated, or maintained in accordance with the instructions provided by Gason; or,
c. to owners other than the original purchaser.
3. if you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this warranty, please contact an
authorised Gason service centre to arrange for an assessment.
4. if, after assessing the heater Gason determines that the heater contains a manufacturing fault, Gason may at its own discretion:
a. replace the heater;
b. repair or replace specic components of the heater; or
c. provide a full refund.
5. parts replaced under warranty are warranted for the balance of their original warranty period.
6. if, at the discretion of Gason the heater or any parts need to be replaced, serviced or repaired at an authorised Gason service centre, then the person
claiming under this warranty must pay all costs associated with:
a. returning the heater; and
b. the delivery or collection of any new or repaired heater.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. Your are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major failure.
Any benets you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under law in relation to the
heater to which these warranties relate.
These warranties are given by:
A.F. Gason Pty Ltd
Blake Street
Ararat Vic 3377
Please contact us if you have any queries on:
Phone: 03 9763 3200
or email us via the “Contact Us” section of our website: www.gason.com.au
A.F. Gason Pty. Ltd. reserves the right to modify or alter specications, materials, etc. in the interest of product improvement.
WARRANTY
Franklin Freestanding Franklin Freestanding
!WARNING
READ AND FOLLOW THESE INSTRUCTIONS FULLY AND CAREFULLY
BEFORE INSTALLING AND USING THIS APPLIANCE.
To aid heater installation, remove door, bae plate and rebricks to reduce
overall heater weight. Refer to the set-up section of this manual.
!WARNING
Safety warnings
• A ue re with resulting damage may occur if the appliance is not
installed and maintained as per this booklet.
• Never place combustible materials such as wood, paper or furniture near
the appliance.
• This appliance is designed to burn dry hardwood. Do not burn
rubbish, driftwood, ammable liquids, pressurised canisters, or any
substance containing salt or corrosives.
• This appliance must not be installed and operated in an area where
kerosene, petrol, paint thinners or other ammable liquid is used or stored.
• The ue system must be inspected and cleaned annually or sooner if
required. Failure to do so could result in excessive build up of creosote
which may result in a ue re, which may damage the ue or cause
damage to your home.
• The surface of the appliance becomes hot during operation. Do not
touch the surface of this appliance. Keep children away from the
appliance during operation. Do not allow anyone to operate this
appliance who is not familiar with this instruction booklet.
!WARNING
Paint curing and care
• Your heater is coated with the best available heat resistant paint. Even
though the paint has been baked after application, it may require further
temperature curing. It may discolour if you overre the heater on its rst
re. Please follow these instructions carefully to ensure the quality of the
paint on your heater is maintained.
• For the rst two or three rings, never exceed Medium air setting and
do not load the re more than half full. Do not use softwood fuel (cut up
pallets, etc.) other than for kindling when rst lighting the re.
• Ensure that the lower air slide is fully closed once the re is established
during the curing process.
• On the initial re up you may detect smoke coming from the paint nish,
and from any oils that may be impregnated in the steel of the rebox.
This is normal. It is suggested to well ventilate your home on the initial
re up.
• Do not wipe the heater while the paint is curing. After the paint has
cured, the only maintenance required to maintain the heater’s nish is
to wipe it with a soft cloth (with water if necessary). DO NOT USE ANY
COMMERCIAL CLEANERS OR SOLVENTS ON THE PAINT FINISH.
• We are proud of the presentation of our products. If at any time you need
to freshen up the paint, your local Jindara dealer has touch-up
paint available for purchase.
The heater is painted in Stove Bright Metallic Black - Paint code 6309.
If you have any enquiries, please contact the dealer from whom you purchased your heater.
PLEASE COMPLETE:
Dealer Name:
Dealer Address:
Email: Phone:
1 14
Firewood
Getting the most out of your rewood
Firewood is a sustainable source of energy and when used correctly can provide a cost eective form of heating in your
home. Too often poor heating results and operational issues are attributed to using unseasoned wood which leads to
excess smoking, causing creosote buildup and dirty glass. Wood should be stored in a dry place where good ventalition is
available. Freshly cut wood should be stored for between 12-24 months before burning.
Use only hardwood with your Jindara Franklin.
Thermal eciency
A wood’s eciency does not depend only on its type, but also on its moisture content as well as the temperature of the
combustion chamber. To achieve a greater eciency and longer burn cycle out of your Jindara Franklin, without the
emissions of hazardous particulates, your wood must be well seasoned.
Ideally, wood should not be burnt when its moisture content is above 20%. A moisture meter to measure moisture
content is a handy investment.
An example of the available thermal eciency for a piece of wood as a fuel source at varying moisture levels.
The combustion process of burning wood
When wood is heated up to approximately 100 degrees celsius, moisture begins to evaporate from the fuel. There is no
heating value from the wood at this point. As moisture releases from the wood, it reduces the eciency of the combustion
process robbing heat energy from the wood. This demonstrates the importance of dry and well seasoned wood.
As rebox temperatures reach 250-300 degrees celsius, wood solids begin to break down and release volatile gases
which ignite and produce heat.
From 300+ degrees celsius, the main energy available from wood is released when fuel vapors containing up to 60% of
the wood’s potential heat is released.
Understanding combustion principles and learning how to manipulate various conditions surrounding the operation of
your Jindara Franklin enables you to achieve maximum comfort and eciency from your Australian made wood heater.
Franklin Freestanding Franklin Freestanding
Jindara Franklin Installation
!WARNING
THE INSTALLATION OF THIS APPLIANCE MUST BE CARRIED OUT AS PER THIS
MANUAL AND THE FLUE MANUFACTURER’S SPECIFICATIONS.
WE RECOMMEND THAT YOU USE A QUALIFIED INSTALLER TO CARRY OUT
THE INSTALLATION OF THIS APPLIANCE.
EXTREME CARE SHOULD BE TAKEN WHEN HANDLING THE APPLIANCE.
If you have any other enquiries regarding installation of the appliance, please
contact the dealer from whom you purchased the heater.
Installation
Scope Of Installation Specications
The Jindara Franklin is tested in accordance with the requirements of AS/NZS 2918:2018 for the congurations
and ue types specied in this manual. Any installation that falls outside of the specications in this manual other than
the addition of bends or extensions to the ue, is considered to be an untested installation as per AS/NZS 2918:2018.
AF Gason Pty. Ltd. accepts no liability whatsoever for the safety of installations under such circumstances.
AF Gason Pty. Ltd. accepts no liability whatsoever for any interpretation of AS/NZS 2918:2018.
It is important that you understand these installation instructions and minimum clearances to combustible
materials before selecting a position for your wood heater, to ensure a safe and correct installation is achieved.
Installation Permit
Depending on your local authority requirements, a permit may be required for the installation of your heater. It is your
responsibility to arrange the same.
Flue Requirements
As per the dimensions in Table A (referencing gures 1 and 2), the Jindara Franklin must be installed with either of the
following ue types:
• Standard 6” Decromesh Default Flue Kit.
• Standard 6” Decromesh Default Flue Kit incorporating an additional 900mm high x 180 degree stainless steel rear
ue shield tted between the Decromesh and the active ue, or
• 6” Half shield Default Kit (Double Sleeve Flue Kit).
NOTE THAT INSTALLATION CLEARANCES ARE DIFFERENT FOR EACH FLUE TYPE.
The ue system installed with the Jindara Franklin must comply with Australian and New Zealand installation standards
AS/NZS 2918:2018, and be installed to the ue manufacturer’s instructions.
The performance of your heater is highly dependant on an eective ue system. In many cases, poor start-up, dirty
glass, down draft causing smoke spillage when the door is open, and reduced heat output can all be caused by the ue
system being too short or incorrectly installed. Excessive ue length is also undesirable, as it can cause excessive ue
draft resulting in short burn times and over-ring of the heater.
Clearance To Combustibles
The Jindara Franklin conforms to AS/NZS 2918:2018 when positioned in relation to combustible surfaces as specied in
Table A (referencing gures 1 and 2), and as per these instructions. The gures shown state the minimum distance the
heater can be placed in relation to any combustible materials - plaster, wallpaper, timber, MDF, etc.
In the instance that your Jindara heater is surrounded by non-combustible materials - brick, stone, concrete, cement
sheet or similar, wall clearances can be reduced to 50mm. A 50mm clearance is required to ensure room air can circulate
around the wood heater during operation.
For further information regarding installation of your heater, please contact the Jindara dealer from whom you
purchased the heater.
Hearth & Floor Requirements
If the Jindara Franklin is to be installed onto a combustible oor, a cement sheet or similar non-combustible hearth or
oor (as per specications on page 3) protector must be placed in between the appliance and the combustible oor.
Minimum hearth requirements are specied in Table A (referencing gures 1 and 2).
If the heater is to be installed onto a non-combustible surface that meets the minimum oor protector requirements
specied, an additional oor protector may not be required.
13 2
Troubleshooting + Tips (continued)
• Sluggish or Lazy Fire
• A sluggish or lazy re can be caused by a number of dierent factors, or a combination of several factors.
• Ensure that the wood you are burning is of good quality, and has been well seasoned to ensure its moisture
content is below 16%. Overly wet wood will cool the re, smoke excessively, and cause your unit to run poorly.
The best way to determine the moisture content of your wood is to use a digital moisture meter. Wood that looks
dry on the outside can still be high in moisture on the inside.
• Ensure that there is not a negative pressure inside your house. Wood burning res consume air as part of the
combustion process. They need a constant supply of air to function correctly. If your home is overly sealed and air
is unable to get to the re as needed, it will create a negative pressure inside the house compared to the outside,
which will cause your re to smoke and run poorly. Running extraction fans in your kitchen or bathroom can also
impact on this in well sealed modern homes. The best way to test for this is to try opening an external door or
window near the heater while it is running, to determine whether it runs better with ready access to outside air.
• Non-standard ue installations can also cause your re to run poorly if not correctly installed. The addition of
bends and elbows in the ue will restrict the ow of ue gasses more than normal, meaning that you may need
to t an additional length of ue in order for your heater to draw properly.
• Environmental factors such as consistent wind, structures or vegetation near the ue outlet, or other unforseen
factors can have a dramatic impact on the performance of your heater. These can usually be overcome by tting
an extra length of ue, or through the tment of a specialty cowl such as a wind chaser or a vertical discharge
cowl.
• Ensure you are putting enough wood in your re. Modern replaces are designed to run hotter and cleaner than
older designs. This means that they perform best when they are well stocked with wood and have a hefty bed
of hot coals. You will become familiar with the unit as you use it, and learn what sort of operation best suits your
needs and wood type. As a general rule it is best to start out by building a big re and then reducing the fuel load
to a level that you nd suitable for your needs. This allows the ue to reach an appropriate operating temperature
for it to draw properly from the beginning, which will promote an active re and good heat output.


Produktspezifikationen

Marke: Jindara
Kategorie: Heizung
Modell: Franklin

Brauchst du Hilfe?

Wenn Sie Hilfe mit Jindara Franklin benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Jindara

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung fĂźr -Kategorien-