WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed
and qualified in pool equipment by the jurisdiction in which the product will be installed where such
state or local requirements exist. The maintainer must be a professional with sufficient experience
in pool equipment installation and maintenance so that all of the instructions in this manual can be
followed exactly. Before installing this product, read and follow all warning notices and instructions
that accompany this product. Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation may void the warranty.
DO NOT MODIFY THIS EQUIPMENT.
Improper installation and/or operation can create unwanted electrical hazard which
can cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given
to the owner/operator of this equipment.
H0771400_REVA
INSTALLATION AND
OPERATION MANUAL
ENGLISH | FRANÇAIS | ESPAÑOL
Jandy Laminar Jet
JLLED4C Series
JLFBR Series
Page 2
ENGLISH Jandy® Laminar Jet | Installation and Operation Manual
Table of Contents
Section 1. Safety Information 3 ..........................
Section 2. General Installation
Requirements 5 ..................................
2.1 Water Source 5 ..............................................
2.2 Pump ..........................................................5
2.3 Plumbing ...................................................5
2.4 LED Light Module 5 .......................................
2.5 Conduit/Fiber Optics Module 5 ......................
2.6 Critical Placement Dimensions 5 ...................
Section 3. Installing the Deck Canister 7 ..........
3.1 In-Deck Installation 7 .....................................
3.2 Out-of-Deck/Planter Box Installation 8 ..........
3.3 Pressure Test Water Lines 9 .........................
3.4 Flush Water Lines 9 .......................................
Section 4. Laminar Jet with LED Light
Installation (Use with JLLED4C
Series) 9 ..............................................
4.1 Preparing the Laminar Jet with
LED Light for Installation 9 ............................
4.2 Installing the Laminar Jet with
LED Light 9 ...................................................
4.3 Wiring Options for Controlling
Laminar Jet with LED Lights 10 .....................
4.4 Twelve (12) Volt Transformer
Installation ................................................11
Section 5. Laminar Jet with Fiber Optic
Module Installation (Use with
JLFBR Series) ...............................11
5.1 Items Required .........................................11
5.2 Installation ................................................11
Section 6. Starting the System ......................11
6.1 Install Jet Assembly ..................................11
6.2 Set up Jet .................................................11
Section 7. Operating the Laminar Jet with
LED Light 12 .......................................
7.1 To Operate the Light and Change
Colors 12 .......................................................
7.2 To Reset to the Beginning of the
Color Sequence 13 ........................................
Section 8. Light Intensity Set Up 13 ...................
8.1 Light Intensity Adjustment Set 13 .................
Section 9. General Maintenance and
Troubleshooting 13 ...........................
9.1 Clogged Finger Screen 13 ............................
9.2 Winterization .............................................14
Section 10. Parts List and Exploded View 14 .....
10.1 Parts List 14 ..................................................
10.2 Exploded View 15 ..........................................
Page 3
Jandy® Laminar Jet | Installation and Operation Manual ENGLISH
Section 1. Safety Information
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This Laminar Jet with LED light must be
installed by a licensed or certified electrician in accordance with the National Electrical Code ® and
applicable local codes and ordinances. In Canada, the Canadian Electrical Code and all applicable local
codes and ordinances must be adhered to. Improper installation will create an electrical hazard, which
could result in death or serious injury to pool or spa users, installers, or others due to electrical shock,
and may also cause damage to property. Read and follow the specific instructions below.
WARNING
Before installing this Laminar Jet with LED light, read and follow all warning notices and instructions
accompanying this product. Failure to follow safety warnings and instructions can result in severe injury,
death, or property damage. Visit www.jandy.com or call (800) 822-7933/ (888) 647-4004 (Canada) for
additional free copies of these instructions.
WARNING
WARNING
ATTENTION INSTALLER: This manual contains important information about the
installation, operation and safe use of this product. This information should be given
to the owner/operator of this equipment.
• Do not connect system to an unregulated city water system or other external source
of pressurized water producing pressures greater than 35 PSI.
• Pressurized air in system can cause product failure or also cause the filter lid to be
blown off which can result in death, serious personal injury, or property damage. Be
sure all air is out of system before operating or testing the equipment.
WARNING
X
WARNING
The maximum operating pressures for pumps, filters, and other equipment are
specified in their individual installation/operating instructions. Never subject the system
to test or operating pressures exceeding these specifications. Pressures above
maximum component operating ratings can cause product failure or cause the filter lid
to be blown off, or other equipment failures which can result in death, serious personal
injury, or property damage.
X


Produktspezifikationen

Marke: JANDY
Kategorie: Nicht kategorisiert
Modell: Laminar Jets

Brauchst du Hilfe?

Wenn Sie Hilfe mit JANDY Laminar Jets benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert JANDY

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-