Seite 1/4
4 – 4.3 GPM (16.3 LPM)
FEATURES
• Self-Priming to 10 ft. (3 m)
• Run Dry Without Damage
• Smooth Flow
• Four Piston, Diaphragm Pump
• Powerful Heavy Duty Motor with Thermal Overload
Protection
• Snap-in Ports
• Waterproof Coating
• Pressure Switch with Rubber Boot (31700-Series)
• Meets USCG Regulation 183.410 and EN ISO 8846
MARINE (Ignition Protection Standards)
• Meets EN 50081-1 Electro-magnetic Compatibility
31705-Series Complies with EN ISO 8849 MARINE
Electric Bilge Pump
GENERAL APPLICATIONS
31700-Series – High velocity pump for anchor and
general deck washdown. Compact size with matched hi-
output spray nozzle. Corrosion resistant coated motor
and sealed pressure switch for fresh or salt water use.
Also great for continuous duty operation in livewell
application at full flow.
31705-Series – For bilge/livewell/G.P. applications that do
not require a pressure switch. Low amp draw, can run dry.
Oil resistant parts allow pumping of diesel fuel. SPECIFICATIONS
• Pump Body – Glass Filled Polypropylene
• Pump Design – Multi-Chamber Diaphragm
• Suction Lift – Self Priming to 10 ft. (3 m)
• Ports – 3/4" (19 mm) Hose Barb or 1/2" (13 mm)
• Motor – Permanent Magnet
• Shipping Weight – Weight - 6.5 lb (3.0 kg)
WARNING!
VARIATIONS
MODELS
31700-0092
31700-0392
31700-0094
31700-0394
31705-0092
31705-0094
APPLICATION
WASHDOWN/BAITWELL
WASHDOWN/BAITWELL
WASHDOWN/BAITWELL
WASHDOWN/BAITWELL
BILGE/LIVEWELL/G.P.
BILGE/LIVEWELL/G.P.
GPM/LPM
4.3/16.3
4.3/16.3
4.3/16.3
4.3/16.3
4.3/16.3
4.3/16.3
VOLTS
12 Vdc
12 Vdc
24 Vdc
24 Vdc
12 Vdc
24 Vdc
SHUT-OFF
psi (bar)
50 (3.5)
50 (3.5)
50 (3.5)
50 (3.5)
N/A
N/A
AMP DRAW
@ 10 psi
7
7
4
4
7
4
@ 40 psi
11
11
6
6
N/A
N/A
FUSE
BREAKER*
15
15
10
10
15
10
* Customer supplied, not included with pump.
Explosion hazard. Do not pump
gasoline, solvents, thinners or other
flammable liquids. To do so can
cause an explosion resulting in
injury or death.
Models 31700, 31705-Series
DIMENSIONAL DRAWINGS — INCHES (mm)
PAR - MAX SERIES
WASHDOWN/BAITWELL — 31700-SERIES
BILGE/LIVEWELL/GENERAL PURPOSE — 31705-SERIES
Bilge/Livewell
Washdown/Baitwell
3.25
(82)
5
(127)
7.73
(196)
4.19
(106)
3.50
(90)
INSTALLATIONS
MOUNTING
The Jabsco pumps are self-priming and may be located
above or below the fresh water supply in a dry location.
To vertically mount these units, it is best to do so with the
motor on top. This will prevent water dripping on motor in
the event of a leak. Place pump on a solid surface and
secure with the four mounting screws being careful not to
compress the rubber grommets which act as shock
absorbers.
PLUMBING
IT IS RECOMMENDED THAT MARINE GRADE
REINFORCED HOSE BE USED FOR ALL PLUMBING
WITH THESE MODELS OF JABSCO PUMPS.
31700-Series – Washdown/Livewell (Fig. 1)
Install the PumpgardTM strainer (provided) to the hose
from the water source (thru-hull seacock or water tank).
Connect the Pumpgard strainer to the pump inlet port.
Connect the pump discharge to a 3-way valve or T (if live-
well has a shutoff valve). Connect to livewell and to hose
bib. From hose bib use new spray nozzle.
31700-Series – w/Rule®Dual Port (Fig. 2)
Install Rule®dual port pump to seacock. Connect hose
from dual port pump to livewell/baitwell tank (see Fig. 2).
Connect washdown hose from dual port pump to
PumpguardTM strainer, connect to pump inlet port.
Connect hose from pump outlet to pressure nozzle.
31705-Series – Bilge/Livewell (Fig. 3)
The 31705-Series pumps can be used as either a bilge
pump or as a bait tank/livewell pump. Connect from bilge
to PumpgardTM strainer (provided) to pump to discharge.
Or from thru-hull seacock to PumpgardTM to pump to
tank.
Note – PumpgardTM strainers should be mounted in the
most accessible place possible to make periodic cleaning
of the screen easier.
WIRING
In an easily accessible location, install a switch to control
electricity to the pump. The switch should have an amp
rating equal to or greater than the fuse size specified for
the pump. Turn the pump off when not used for extended
periods or when the tank is empty.
The electrical circuit should be protected with an over-
current protection device in the positive lead. See chart
for proper size. The pump circuit should not include any
other electrical loads. The open terminal on the pressure
switch is positive. Black wire from the motor is negative.
Select wire size from chart below. Use total length of wire
from the battery to pump and return. Chart allows for 3%
voltage drop. If in doubt, use next larger wire size.
If you are not familiar with applicable electrical stan-
dards, have the unit installed by a qualified electri-
cian.
After installation, check the voltage at the pump motor.
Voltage should be checked when pump is operating. Full
voltage must be available at the pump motor at all times.
OPERATION
1. Open seacock (washdown or livewell applications).
2. Open hose bib and/or spray nozzle (31700-Series) or
make sure discharge thru-hull is clear (31705-Series).
3. Turn on pump.
4. 31700-Series. Close spray nozzle/hose bib when water
runs free of air. Pump is now ready for automatic
demand operation.
5. 31705-Series. Pumps do not have a pressure switch
and are usually switched manually.
6. For prolonged operation, pump must operate at full
open flow.
CAUTION!
Motor case will get hot.
Prolonged contact during
operation may cause a burn.
Fig. 1
31700-Series
Fig. 2
31700-Series w/Rule®Dual Port
Fig. 3
31705-Series
Quick Easy Installation
Versatile Snap-in Ports
Total length
in feet
12 Volt
24 Volt
0-20
(0-6 m)
#14 AWG
(2.5 mm2)
#16 AWG
(1.5 mm2)
20-35
(6-11 m)
#12 AWG
(4 mm2)
#14 AWG
(2.5 mm2)
35-55
(11-17 m)
#10 AWG
(6 mm2)
#12 AWG
(4 mm2)
TM
Bilge Pump
Pumpguard
Inlet Strainer
TM
WARNING: DISCONNECT POWER TO PUMP AND OPEN VALVE TO
RELIEVE WATER PRESSURE PRIOR TO SERVICING PUMP
DISASSEMBLE
Pressure Switch (5)
1. Disconnect power to pump and open a faucet or valve to relieve
system pressure.
2. Remove Rubber Boot, then remove the two visible Pressure
Switch Screws located on each side of the Pressure Switch (5).
Upper Housing (1)
3. Slide Port Clip (8) back and unplug from Tank Plumbing.
4. Loosen but DO NOT remove the four Pump Head Screws and
carefully remove Upper Housing Assembly (1).
5. Remove Check Valve (2) and inspect for debris.
Check Valve Assembly (2)
Follow Steps 1, 3 & 4
6. Inspect Check Valve (2) and O-Ring
Lower Housing (4)
Follow Step 1, 3 & 4
7. Remove Rubber Plugs on housing (4-A) to access Allen Screw.
8. Rotate Lower Housing (4), so access notch is aligned with Cam
Bearing Set Screw (4-C), loosen set screw with a 1/8" Allen
Wrench and slide pump head off motor shaft.
Diaphragm (3-B)
9. Loosen four cam piston screws with Phillips head screw driver
and pull apart cam (4-B) from Inner Pistons (3-A). (Both pistons
(3-A & C) should be replaced when a new Diaphragm (3-B) is
installed.)
Motor (7)
Follow steps 1, 3, 4, 7, & 8
REASSEMBLE
Diaphragm (3-B)
1. Insert Outer Pistons (3-C) into Lower Housing (4-A) by bending pistons
at center fold.
2. Placing the Diaphragm (3-B) (flatter side of Diaphragm facing the
motor) on the Lower housing (4-A). Press each Inner Piston (3-A)
through the Diaphragm and Lower Housing (4A) into Outer Piston
(3-C). Hex stem of Inner Pistons (3-A) must be aligned into hex holes in
Outer Pistons (3-C). Tighten cam piston screws partially, center pis-
ton in diaphragm, and tighten screws securely (18 in. lbs. torque). Also,
the Outer Pistons (3-C) must be aligned with alignment slots on Cam
Assembly (4-B) making sure screw holes align in cam assembly, other-
wise diaphragm will leak.
Cam Bearing (4-B)
3. Place Cam Bearing (4-B) over Inner Pistons (3-C) and tighten
down with four Phillips Head Screws. (18 in. lbs. torque)
Lower Housing (4) to Motor (7)
Coat motor shaft with grease prior to installing Cam Bearing (4-B).
4. When installing the Lower Housing (4), rotate access notch to align
with Cam Bearing Set Screw (4-C).
5. Attach Cam Bearing (4-B) to motor shaft indentation with Cam Bearing
Set Screw (4-C). (35 in. lbs. torque)
6. Reinsert new Notch Plugs.
Check Valve (2)
7. Place Ferrules (Rubber Cones) in the Upper Housing (1) coned side
first.
8. Properly seat O-Ring in Check Valve (2) and insert Check Valve (2) into
the Upper Housing (1).
Upper Housing (1)
9. Place Upper Housing (1) on top of the Lower Housing (4-A) and tighten
Hex Bolts (30 in. lbs. torque) through the Upper Housing (1) to the
Motor.
* Service kit includes Keys 2, 3 and 4B, C, D and 8
KEY DESCRIPTION
1
2
3
4
5
*6*
7
8
9
QTY
1
1
1
1
1
1
1
1
1
1
1
1
1
Upper Housing
Valve Kit
Diaphragm Kit
Lower Housing Kit
Pressure Switch
Service Kit
Motor Kit – 12V EMC COMP
24V EMC COMP
Slide Clips
Pumphead Assy.
PumpgardTM Strainer
Spray Nozzle US
Spray Nozzle EC
18910-4000
18911-7010
18912-3050
18915-9005
N.A.
18920-9053
18919-0140
18919-1062
30648-1000
18914-6300
46400-0000
31705-SERIES — PART NO.
18910-4050
18911-7030
18912-3040
18915-9002
18916-0050
18920-9043
18919-0140
18919-1062
30648-1000
18914-6350
46400-0000
30703-1000
30704-1000
31700-SERIES — PART NO.
EXPLODED VIEW
Produktspezifikationen
Marke: | Jabsco |
Kategorie: | Wasserpumpe |
Modell: | Par Max 4 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Jabsco Par Max 4 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wasserpumpe Jabsco
28 Oktober 2022
Bedienungsanleitung Wasserpumpe
- Wasserpumpe Cotech
- Wasserpumpe LG
- Wasserpumpe Makita
- Wasserpumpe Bosch
- Wasserpumpe Parkside
- Wasserpumpe Vonroc
- Wasserpumpe Cocraft
- Wasserpumpe Topcraft
- Wasserpumpe Trotec
- Wasserpumpe Dometic
- Wasserpumpe Atlantic
- Wasserpumpe Einhell
- Wasserpumpe Mitsubishi
- Wasserpumpe Eheim
- Wasserpumpe Eurom
- Wasserpumpe Hitachi
- Wasserpumpe Hyundai
- Wasserpumpe Metabo
- Wasserpumpe Kärcher
- Wasserpumpe Güde
- Wasserpumpe Scheppach
- Wasserpumpe Meec Tools
- Wasserpumpe Fieldmann
- Wasserpumpe King Craft
- Wasserpumpe Westfalia
- Wasserpumpe Vaillant
- Wasserpumpe Remko
- Wasserpumpe Pattfield
- Wasserpumpe Silverline
- Wasserpumpe Sthor
- Wasserpumpe Maxxmee
- Wasserpumpe Florabest
- Wasserpumpe Germania
- Wasserpumpe Hecht
- Wasserpumpe Kranzle
- Wasserpumpe De Dietrich
- Wasserpumpe Wiltec
- Wasserpumpe Zipper
- Wasserpumpe Yato
- Wasserpumpe Fluval
- Wasserpumpe Tetra
- Wasserpumpe Vetus
- Wasserpumpe Viessmann
- Wasserpumpe Dimplex
- Wasserpumpe Buderus
- Wasserpumpe Hayward
- Wasserpumpe Gre
- Wasserpumpe Bavaria
- Wasserpumpe Toolcraft
- Wasserpumpe Fujitsu
- Wasserpumpe JUNG
- Wasserpumpe Bestway
- Wasserpumpe Intex
- Wasserpumpe AL-KO
- Wasserpumpe Gardena
- Wasserpumpe CMI
- Wasserpumpe Alphacool
- Wasserpumpe SereneLife
- Wasserpumpe Neptun
- Wasserpumpe Bulex
- Wasserpumpe Danfoss
- Wasserpumpe Hozelock
- Wasserpumpe Eden
- Wasserpumpe Swim & Fun
- Wasserpumpe Nibe
- Wasserpumpe Daikin
- Wasserpumpe Norsup
- Wasserpumpe Duro Pro
- Wasserpumpe Duromax
- Wasserpumpe Eurogarden
- Wasserpumpe Ferrex
- Wasserpumpe Flojet
- Wasserpumpe Garden Feelings
- Wasserpumpe Gardenline
- Wasserpumpe Grizzly
- Wasserpumpe Hydro-Pro
- Wasserpumpe Kibani
- Wasserpumpe Maxicool
- Wasserpumpe Oase
- Wasserpumpe OKAY
- Wasserpumpe Plantiflor
- Wasserpumpe Tanaka
- Wasserpumpe WHALE
- Wasserpumpe Wingart
- Wasserpumpe Esotec
- Wasserpumpe Sunforce
- Wasserpumpe T.I.P.
- Wasserpumpe Wolfcraft
- Wasserpumpe Heissner
- Wasserpumpe DAB
- Wasserpumpe VT
- Wasserpumpe Truper
- Wasserpumpe JANDY
- Wasserpumpe Liberty Pumps
- Wasserpumpe Elpumps
- Wasserpumpe For_Q
- Wasserpumpe Pontec
- Wasserpumpe Ashland
- Wasserpumpe Proviel
- Wasserpumpe Zoeller
- Wasserpumpe Anova
- Wasserpumpe Yellow Garden Line
- Wasserpumpe Fiap
- Wasserpumpe Little Giant
- Wasserpumpe Waterco
- Wasserpumpe Ergotools Pattfield
- Wasserpumpe Sunnydaze Decor
- Wasserpumpe Ebara
- Wasserpumpe Pentair
- Wasserpumpe Flotide
- Wasserpumpe Ribimex
- Wasserpumpe Coral Box
- Wasserpumpe Nowax
- Wasserpumpe GARANTIA
- Wasserpumpe Reefe
- Wasserpumpe AquaForte
- Wasserpumpe Maxbear
- Wasserpumpe Tallas
Neueste Bedienungsanleitung für -Kategorien-
11 Oktober 2024
8 Oktober 2024
4 Oktober 2024
4 Oktober 2024
2 Oktober 2024
30 September 2024
29 September 2024
27 September 2024
20 September 2024
18 September 2024