MODELS:
23680-4003 12V DC
23680-4103 24V DC
COMMERCIAL DUTY
WATER PUPPY
FEATURES:
Continuous rated, medium duty pumps for
bilge and general purpose use.
l ISO 8846 MARINE (Ignition protection).
l ISO 8849 MARINE (Bilge pump standard).
l Small bilge debris present no problem to
these bronze bodied, flexible impeller
pumps.
l Simple design means fewer wearing
parts.
l 32 lpm (6.5 UK gpm) output @ 3m (10ft)
head.
l Self priming to 1.2m (4 ft).
INSTALLATION INSTRUCTIONS:
Jabsco Water Puppy can be mounted on any flat
surface. Fit the pump in a dry, well ventilated
position where there is full access for service. If
installed in a vertical position the motor must be
above the pump head. Use the rubber grommets
provided to minimise vibration, do not overtighten the
mounting screws.
Secure 25mm (1”) id hose either direct to the
discharge ports or to ½” BSP male threaded fittings
using stainless steel hose clamps. Use spiral
reinforced hose (with a smooth internal bore) that will
not collapse under suction, or rigid or semi rigid
pipework systems. The pipework must be compatible
with the liquid being pumped. Pipe runs should be
kept as straight and short as possible, avoiding rising
and dipping over obstructions. Fit a strainer on the
inlet hose to prevent larger debris from entering the
pump.
WIRING INSTRUCTIONS
Make all electrical connections in dry locations,
connections in humid environments should be sealed
to prevent corrosion. Protect the circuit with a
correctly rated fuse or circuit breaker in the orange
positive (+) lead as close as possible to the power
source. Connect the black motor wire to the negative
(-) battery terminal. Inadequate voltage at the motor
terminals when the pump is running (not less than
10% below rated voltage at full load) due to partially
discharged batteries or insufficient cable size may
result in blowing fuses, failure to start or poor pump
performance.
WARNING: If the fuse fails
repeatedly do not fit a heavier fuse or
bridge the fuse terminals with silver
paper or metal wire. Failure to observe
this instruction may result in a fire
hazard due to overheating of cables.
WARNING: All marine pumps
discharging overboard must be
installed with the overboard discharge
well above both static and heeled
waterlines.
m ft lpm UK gpm
2 7 35 7.7
3 10 32 7
4 13 30 6.6
6 20 25 5.5
WATER PUPPY PERFORMANCE
TOTAL HEAD
WATER PUPPY
Approximate performance for new pump,
running water at 20°C with fully charged battery
WARNING: Do not use any Jabsco
pump for petrol, petroleum products or
any products with a flash point below
37°C (98°F), explosion or death may
occur.
MODEL
NO.
VOLTAGE
MAXIMUM
AMP
DRAW
MAXIMUM
FUSE
SIZE
MINIMUM
WIRE
SIZE
MAXIMUM LENGTH
BETWEEN (+) & (-)
BATTERY TERMINALS
23680-4003 12 volt 13 amp 15 amp
30 / 0.25mm
(1.5mm²)
4.5m (15ft) *
32 / 0.2mm
(1.0mm²)
ELECTRICAL WIRING INFORMATION
23680-4103
24 volt
6 amp
10 amp
4.5m (15ft) *
DIMENSIONAL DRAWING & PARTS LIST
WEIGHT: Water Puppy - 3.0kg (6.6lb)
Warranty: All products of the company are sold and all services of the company are offered subject to the company’s warranty and terms and conditions of sale, copies of which will be furnished upon request.
© 2011 Xylem, Inc Rev B 11/2012
100 Cummings Center, Ste 535-N, Beverly, MA 01915
+1 978 281 0440 +1 978 283 2619
KEY DESCRIPTION QUANTITY PART NO.
1 End Cover Screw * 3 SP1004-09
2 End Cover 1 9328-0200
3 Impeller * 1 6303-0003
4 O-ring * 1 X5251-049
5 Body 1 23064-2100
6 Seal * 1 SP2701-52
7 Screw (pump to motor) 2 X3001-147F
8 Slinger 1 6342
Motor 12V 1 74001-2652B
Motor 24V 1 74001-2653B
SK224
WATER PUPPY PART LIST
Service Kit (Contains Items Marked *)
9
* For longer installations, fit thicker cables
Produktspezifikationen
Marke: | Jabsco |
Kategorie: | Pumpe |
Modell: | 23680-4003 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Jabsco 23680-4003 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Pumpe Jabsco
9 April 2024
13 November 2022
6 November 2022
Bedienungsanleitung Pumpe
- Pumpe Crivit
- Pumpe SilverCrest
- Pumpe SKS
- Pumpe Quigg
- Pumpe Makita
- Pumpe Parkside
- Pumpe Vonroc
- Pumpe Siemens
- Pumpe Powerfix
- Pumpe Trotec
- Pumpe Outwell
- Pumpe Einhell
- Pumpe Bartscher
- Pumpe Telestar
- Pumpe Tacklife
- Pumpe Ultimate Speed
- Pumpe Eheim
- Pumpe Eurom
- Pumpe Hyundai
- Pumpe Fuxtec
- Pumpe Metabo
- Pumpe Kärcher
- Pumpe GĂĽde
- Pumpe Biltema
- Pumpe Fieldmann
- Pumpe Enermax
- Pumpe Michelin
- Pumpe Florabest
- Pumpe Germania
- Pumpe Zipper
- Pumpe EUFAB
- Pumpe Sanibroyeur
- Pumpe Batavia
- Pumpe Topeak
- Pumpe Hayward
- Pumpe Milwaukee
- Pumpe Toolcraft
- Pumpe Osram
- Pumpe Bestway
- Pumpe AL-KO
- Pumpe Gardena
- Pumpe Verto
- Pumpe Powerplus
- Pumpe Cannondale
- Pumpe Lezyne
- Pumpe Neptun
- Pumpe Sicce
- Pumpe Danfoss
- Pumpe Hozelock
- Pumpe Ozito
- Pumpe Ferroli
- Pumpe Nibe
- Pumpe Sun Joe
- Pumpe Fluke
- Pumpe Generac
- Pumpe Lavorwash
- Pumpe Oase
- Pumpe OKAY
- Pumpe Plantiflor
- Pumpe Velda
- Pumpe Waldbeck
- Pumpe Zodiac
- Pumpe AstralPool
- Pumpe T.I.P.
- Pumpe Heissner
- Pumpe DAB
- Pumpe Baracuda
- Pumpe Rule
- Pumpe JANDY
- Pumpe Park Tool
- Pumpe Lifan
- Pumpe Elpumps
- Pumpe For_Q
- Pumpe Simpson
- Pumpe Pontec
- Pumpe BluGarda
- Pumpe Grundfos
- Pumpe Superior Pump
- Pumpe Zoeller
- Pumpe SHURflo
- Pumpe Ergotools Pattfield
- Pumpe Ebara
- Pumpe Basement Watchdog
- Pumpe Madimack
- Pumpe Barwig
- Pumpe Wayne
- Pumpe SANDPIPER
- Pumpe Zehnder Pumpen
Neueste Bedienungsanleitung fĂĽr -Kategorien-
26 Juni 2024
26 Juni 2024
26 Juni 2024
26 Juni 2024
25 Juni 2024
14 Juni 2024
4 Juni 2024
4 Juni 2024