100 / 100-S Series Valves
Installation Instruction
100 Series Valve
Built on proven technologies and
components, the Irritrol 100 Series valves
are tough, have excellent performance,
and are extremely reliable. A self-cleaning
metering system and 220 PSI rating
assures years of trouble-free performance.
100S Series “Scrubber” Valve
Constructed of heavy-duty, glass-
reinforced nylon, high grade stainless
steel, brass and EPDM rubber materials,
the 100 Series scrubber valves resist
clogging. The patent-pending continuous
scrubbing mechanism actively îšżghts dirt,
algae and other particles from disrupting
the functionality of the valve. The 100
Series scrubber valves are true dirty water
irrigation valves, able to handle the harsh
chemicals found in dirty water systems,
such as chlorines, chloramines and water
treated with ozones.
Installation Recommendations
• In commercial installations, it is
advantageous to install the valves in
a valve box. This enables the valve
to be easily located, accessed, and
maintained.
• Partially ll the bottom of the valve
box with clean aggregate to faciliate
drainage.
• Locate the valve box away from
structures, hardscape features (such as
sidewalks), and large planting locations.
• Locate the valve box in shrub beds and
at right angles to structure locations.
• If valves are installed below grade
without
a valve box, access to the top
of the valve should be provided by
using a section of 4” PVC pipe and a
valve cover installed directly over each
valve.
Introduction
100P1
100P1.5
100P2
100P3
2
Features
Specifications
100 Series Valve
• 220 PSI maximum pressure rating
• Removable, self-cleaning metering
system
• Precise pressure control with
optional Omni-Reg® pressure
regulator (îšżeld installed)
• Manual ow control: adjustable to
zero ow
• Internal manual bleed screw:
bleeds internally downstream
• External manual bleed screw:
bleeds to atmosphere, allows
cleaning of metering rod and
provides maximum ushing
100S Series “Scrubber” Valve
• All the great features of the 100
Series valve.
• Continuous scrubbing turbine
actively cleans the metering device
for consistent valve operation in
dirty water applications.
Models:
100/100S Series electric
1”, 1½”, 2”, and 3”
Body Style:
Globe/Angle with female threads (all
models)
BSP threads available
Dimensions:
1”: 6¾” H x 3⅝” W
1½”: 7¼” H x 3” W
2”: 9½” H x 6⅛” W
3”: 10¾” H x 6⅛” W
Flow range: 5 - 300 GPM
Burst pressure safety rating:
450-500 PSI
Operating Pressure:
20-220 PSI maximum
Minimum pressure differential:
20 PSI
(between inlet and outlet)
Solenoid (standard): 24 VAC
Inrush: 0.40 amps, 11.50 VA; Max.
Inrush: 0.50 amps
Holding: 0.20 amps, 5.75 VA; Max.
Holding: 0.30 amps
Voltage Requirement (based on inlet
pressure):
22.5 V a.c. @ 220 PSI
21.1 V a.c. @ 200 PSI
20.2 V a.c. @ 175 PSI
19.1 V a.c. @ 150 PSI
18.2 V a.c. @ 125 PSI
16.1 V a.c. @ 75 PSI
16.0 V a.c. @ 50 PSI
!
Using pipe dope on valve
connections can cause thread
damage and failure of the valve
body.
Use only PTFE tape or pipe
thread sealant.
• Note the ow direction arrows
on the bonnet or body and install
accordingly.
• The valve can be installed at any
angle without affecting operation.
• The valve body plug and o-ring must
be properly installed in the unused
inlet.
• Use direct-burial wire, utilizing
different color codes for each station
control wire and one color for the
common wire to all valves.
• Waterproof wire splice connectors
are absolutely essential for proper
electric control system operation.
Follow the installation instructions
provided with the connectors
for optimum waterproof splice
protection.
• Leaving a wire expansion loop at
each valve location on long-run wire
lengths is recommended.
Installation Guidelines
3
Flow Control
Knob
External Manual
Bleed Knob
Internal Manual
Bleed Knob
Valve Operation
Flow Control
Flow control
reduces the ow
and pressure to
valve outlet. By
turning the control
handle clockwise,
the ow will be
gradually reduced
to zero.
Internal Manual
Bleed Knob
The internal
manual bleed
system is used to
manually operate
the valve. Turning
the internal
bleed knob
(located beneath
the solenoid)
counterclockwise
allows water
to bleed
downstream from
the diaphragm
chamber. Internal
pressure is relieved from the top of the diaphragm, allowing the valve to open.
Turning the bleed knob clockwise until tight shuts off the discharge enabling
pressure to build within the diaphragm chamber, causing the valve to close.
External Manual Bleed Knob (ush mode)
The external manual bleed knob, located on top of the ow control handle, is
used for system ushing. Turning this knob counterclockwise allows water in the
diaphragm chamber to vent to atmosphere, creating maximum opening power
and debris ushing action. This operation bypasses the regulator (if installed) and
opens the valve fully, regardless of regulator setting. In addition, the metering
rod (attached to the external bleed knob) can be easily removed for cleaning as
necessary.
100S Scrubber Operation
Patented scrubber impeller
Continuous scrubbing turbine
actively cleans the metering
device for consistent valve
operation in dirty water
applications.


Produktspezifikationen

Marke: Irritrol
Kategorie: Nicht kategorisiert
Modell: 100P3N

Brauchst du Hilfe?

Wenn Sie Hilfe mit Irritrol 100P3N benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Irritrol

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĂĽr -Kategorien-