1
Combi Compact
HRE 24/18
HRE 28/24
HRE 36/30
HRE 36/40
Operating Instructions
Installation of the appliance may only be carried out by an installer/competent person.
Please ask your installer to instruct you on how to fill and bleed the appliance and the
installation and on their operation. Strictly abide by all the instructions and warnings.
Always use the appliance in accordance with the Operating Instructions. It is forbidden to
interfere with a sealed component.
CONTENTS
1 Operation of the appliance 2
1.1 Operation of the central heating ................................................................. 2
1.2 Operation of domestic hot water supply ..................................................... 2
2 Operation and display read- 2 out
2.1 Operating mode on the service display 3 ......................................................
2.2 Changing the settings of the various functions ........................................... 3
3 Start- 3 up
4 Faults 3
5 Filling and bleeding appliance and installation 4
5.1 Central heating system ............................................................................... 4
5.2 Domestic hot water supply .......................................................................... 4
5.3 Frost protection ........................................................................................... 4
6 Maintenance 4
© 2012 Intergas Heating Ltd Subject to change.
2
Intergas Heating Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic
heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and
promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk. Please ensure that the installer has fully
completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that
you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of
complying with the appropriate Building Regulations (England and Wales). All Installations must be notified to Local Aerea Building Control either directly or
through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the
Notification Number on the Benchmark Checklist. This product should be serviced regularly to optimise its safety, efficiency and performance. The service
engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark cheklist may be required in the
event of any warrranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information
Pack.
1 OPERATION OF THE APPLIANCE
The purpose of the Intergas Combi Compact HRE wall mounted gas fired boiler is to heat water and to supply it to the central heating
(CH) system and the domestic hot water (DHW) taps. The heat exchanger comprises of two separate systems for central heating and
DHW. The appliance is fitted with a modulating control. This means that the power is adjusted in line with the required heat. The boiler
controller responds to each call for heat from the heating or the DHW system by igniting the burner and monitoring the flame.
1.1 Operation of the central heating
The call for heat arises as a result of the room temperature being lower than the temperature set on the room thermostat. If at that time
the appliance does not have a call for DHW, the appliance comes on in central heating mode. The central heating temperature control
modulates on the basis of the set central heating supply temperature. This means that when the desired central heating supply
temperature is approached the appliance adjusts the power. The pump for the central heating has a post purge period of 1 minute. The
post purge period may be changed if desired. The pump runs automatically for 10 seconds once every 24 hours to prevent blocki ng.
1.2 Operation of domestic hot water supply
The DHW system is started automatically as soon as more than 2 litres of water per minute are drawn. During delivery of hot tap water
no heat is supplied by the appliance to the central heating system.
For purposes of fast delivery of hot tap water a DHW comfort function has been installed in the controller. This function maintains the
temperature of the heat exchanger. The DHW comfort function has the following settings:
On: ( is turned on continuously. In this mode the heat exchanger will be kept on LED on) The appliance’s DHW comfort function
temperature to assure instant delivery of hot water.
Eco: ( LED on) The appliance’s DHW comfort function is an intelligent system. The appliance will adapt to the pattern of use of hot tap
water. As a result, the temperature of the heat exchanger will only be maintained in periods during which domestic hot water was drawn
on previous days.
Off: (Both LEDs off) The temperature of the heat exchanger is not maintained, as a result of which the delivery of hot tap water takes a
little time. If there is no need for rapid delivery of hot tap water, the DHW comfort function can be switched off.
2 OPERATION AND DISPLAY READ-OUT
Read-out
Operation
1
On / off
A
On / Off button
2
CH operation or setting maximum CH temperature
B
DHW / CH button, for setting desired temperature
3
DHW operation or setting DHW temperature
C
- button
4
Desired temperature of CH or DHW in °C / CH water pressure (bar) / Fault code/ Time
D
+ button
5
Clock “on” CH enabled
E
Clock function setting
6
Clock “off” CH disabled
F
DHW comfort function off / eco / on
7
DHW comfort function eco
G
Service button
8
DHW comfort function on (continuous)
H
Reset button
9
Operating code
10
Flashes to indicate fault
3
2.1 Operating mode on the service display:
Off (appliance frost protection active)
Ventilate
Wait mode
Ignite
CH pump post run
CH mode
Desired temperature reached
DHW mode
Self test
Heat up appliance
Note: When the red LED above the reset key flashes a fault has occurred. A fault code will then appear on the temperature/clock display.
2.2 Changing the settings of the various functions
Keeping the key pressed for 2 seconds takes you to the user settings menu (LED at display starts to flash). and the
Then each time you press the key a different function LED will start to flash. The value of the function can be set using the
and keys. The value set is displayed on the display.
The reset key closes the settings menu and stores the changes.
If no key is pressed for 30 seconds, the settings menu is automatically closed and the changes are stored.
The on/off key closes the settings menu without storing the changes.
The t setting for the switch moments (hold for 5 seconds). button restores the defaul
By pressing the or keys the clock can be set and the switch moments can be defined.
By pressing the button 2 time blocks can be programmed in which the CH is on (switch moments 1 to 4).
By pressing the button the new times will be stored in the boiler controller. In the display appears [P] for a short period.
Pressing the button for less than 1 second the following additional functions can be activated:
1. t-on (temporary on), the boiler will respond on every CH demand from the room thermostat until the next switch moment.
2. c-on (continuous on), the boiler will respond on every CH demand from the room thermostat without any time limit.
3. OFF, the boiler will not respond on any CH demand from the room thermostat.
. Can be set between 30°C and 90°C (standard setting 80°C). The maximum CH supply temperature
Low setting for moderately cold weather, high setting for colder weather.
DHW temperature. Can be set between 40°C and 65°C (standard setting 55°C).
All other alterations of settings of the boiler may only be carried out by your installer.
3 START- UP
Once the appliance has been connected to water, gas and electricity supplies and
checked by an authorised installer, the appliance can be started.
Please check the following points:
The central heating system and domestic hot water system must be well filled and bled.
The appliance must be switched off (Horizontal dash on service display, other LEDs off).
The water pressure in the central heating system must be between 1 and 2 bar (Shown on the temperature display).
Never switch the appliance on if the appliance, the CH system and the DHW system have not been completely filled and bled.
The room thermostat must be set below the temperature in the room.
The gas tap must be open.
Switch the appliance on with the on/off key in the display (The LED lights up, and the service display goes out). The appliance
may now heat up for purposes of the DHW system until the heat exchanger reaches the set temperature.
Set the clock and the switch moments. If the boiler is in a time block that CH is not active the boiler must be set in c-on (see §2.2).
Set the room thermostat higher than the actual room temperature. The appliance will fire for purposes of the CH system.
4 FAULTS
If the following simple appliance faults occur, they can be resolved as follows. In the case of repeated occurrence or other faults
always notify your installer.
1. The CH system does not heat up or does not become sufficiently warm:
Increase the temperature setting at the room thermostat.
Open the radiator valves.
Increase the CH water temperature setting using the key on the operating panel (see §2 and the and ).
Bleed the appliance and installation and check the CH water pressure.
2. The domestic hot water supply does not become hot or hot enough:
Open the domestic hot water tap further.
Set the domestic hot water temperature higher using the key on the operating panel (see §2 and the and ).
3. key is flashing. The following codes are indicated on the display (4): The fault LED above the reset
The appliance becomes too hot, there is insufficient flow. Open the radiator valves, bleed the appliance and
installation and check the CH water pressure. If necessary top up (see §5 )
The burner does not light. Consult your installer.
Produktspezifikationen
Marke: | Intergas |
Kategorie: | Zentralheizungskessel |
Modell: | Combi Compact HRE 36/40 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Intergas Combi Compact HRE 36/40 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Zentralheizungskessel Intergas
18 September 2024
18 September 2024
5 August 2024
2 August 2024
21 Juli 2024
16 Juli 2024
16 Juli 2024
15 Juli 2024
12 Juli 2024
12 Juli 2024
Bedienungsanleitung Zentralheizungskessel
- Zentralheizungskessel Bosch
- Zentralheizungskessel ATAG
- Zentralheizungskessel Inventum
- Zentralheizungskessel EAS Electric
- Zentralheizungskessel Vaillant
- Zentralheizungskessel Junkers
- Zentralheizungskessel De Dietrich
- Zentralheizungskessel Thermex
- Zentralheizungskessel Remeha
- Zentralheizungskessel Saunier Duval
- Zentralheizungskessel Stiebel Eltron
- Zentralheizungskessel Truma
- Zentralheizungskessel Viessmann
- Zentralheizungskessel Buderus
- Zentralheizungskessel Baxi
- Zentralheizungskessel Wolf
- Zentralheizungskessel Itho Daalderop
- Zentralheizungskessel Bulex
- Zentralheizungskessel Fantini Cosmi
- Zentralheizungskessel Roc
- Zentralheizungskessel Ariston Thermo
- Zentralheizungskessel La Nordica
- Zentralheizungskessel Mikoterm
- Zentralheizungskessel Ferroli
- Zentralheizungskessel Nibe
- Zentralheizungskessel Elco
- Zentralheizungskessel Daalderop
- Zentralheizungskessel Itho
- Zentralheizungskessel Morco
- Zentralheizungskessel Nefit
- Zentralheizungskessel Oertli
- Zentralheizungskessel Thermona
- Zentralheizungskessel ACV
- Zentralheizungskessel Tzerra
- Zentralheizungskessel Weishaupt
- Zentralheizungskessel Ygnis
- Zentralheizungskessel Vokèra
- Zentralheizungskessel ETA Heiztechnik
- Zentralheizungskessel A.O. Smith
- Zentralheizungskessel AGPO
- Zentralheizungskessel Glow-worm
- Zentralheizungskessel Masterwatt
- Zentralheizungskessel Halstead
- Zentralheizungskessel AWB
- Zentralheizungskessel Ravenheat
- Zentralheizungskessel Brink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
15 Oktober 2024
14 Oktober 2024
13 Oktober 2024
10 Oktober 2024
8 Oktober 2024
8 Oktober 2024
7 Oktober 2024
7 Oktober 2024
5 Oktober 2024