Intergas Combi Compact ECO RF 36 Bedienungsanleitung

Intergas Zentralheizungskessel Combi Compact ECO RF 36

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Intergas Combi Compact ECO RF 36 (4 Seiten) in der Kategorie Zentralheizungskessel. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
1
Combi Compact
ECO RF 24
ECO RF 30
ECO RF 36
Operating Instructions
Installation of the appliance may only be carried out by an installer/competent person.
Please ask your installer to instruct you on how to fill and bleed the appliance and the
installation and on their operation. Strictly abide by all the instructions and warnings.
Always use the appliance in accordance with the Operating Instructions. It is forbidden to
interfere with a sealed component.
CONTENTS
1 Operation of the appliance 2
1.1 Operation of the central heating ................................................................. 2
1.2 Operation of domestic hot water supply ..................................................... 2
2 Operation and display read-out 2
2.1 Operating mode on the service display ...................................................... 3
2.2 Changing the settings of the various functions ........................................... 3
3 Start-up 3
4 Faults 3
5 Filling and bleeding appliance and installation 4
5.1 Central heating system ............................................................................... 4
5.2 Domestic hot water supply .......................................................................... 4
5.3 Frost protection ........................................................................................... 4
6 Maintenance 4
© 2013 Intergas Heating Ltd Subject to change.
2
Intergas Heating Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic
heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and
promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk. Please ensure that the installer has fully
completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that
you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of
complying with the appropriate Building Regulations (England and Wales). All Installations must be notified to Local Aerea Building Control either directly or
through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the
Notification Number on the Benchmark Checklist. This product should be serviced regularly to optimise its safety, efficiency and performance. The service
engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark cheklist may be required in the
event of any warrranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information
Pack.
1 OPERATION OF THE APPLIANCE
The purpose of the Intergas Combi Compact ECO RF wall mounted gas fired boiler is to heat water and to supply it to the central
heating (CH) system and the domestic hot water (DHW) taps. Any use deviating from the intended use by the manufacturer may result
in product damage or unsafe situations and will void the warranty.
The heat exchanger comprises of two separate systems for central heating and DHW. The appliance is fitted with a modulating control.
This means that the power is adjusted in line with the required heat, the boiler controller responds to each call for heat from the heating
/DHW system by igniting the burner and monitoring the flame.
1.1 Operation of the central heating
The call for heat arises as a result of the room temperature being lower than the temperature set on the room thermostat. If at that time
the appliance does not have a call for DHW, the appliance comes on in central heating mode. The central heating temperature control
modulates on the basis of the set central heating supply temperature. This means that when the desired central heating supply
temperature is approached the appliance adjusts the power. The pump for the central heating has a post purge period of 1 minute. The
post purge period may be changed if desired. The pump runs automatically for 10 seconds once every 24 hours to prevent blocking.
1.2 Operation of domestic hot water supply
The DHW system is started automatically as soon as more than 2 litres of water per minute are drawn. During delivery of hot tap water
no heat is supplied by the appliance to the central heating system.
For purposes of fast delivery of hot tap water a DHW comfort function has been installed in the controller. This function maintains the
temperature of the heat exchanger. The DHW comfort function has the following settings:
On: ( LED on) The appliance’s DHW comfort function is turned on continuously. In this mode the heat exchanger will be kept on
temperature to assure instant delivery of hot water.
Eco: ( LED on) The appliance’s DHW comfort function is an intelligent system. The appliance will adapt to the pattern of use of hot tap
water. As a result, the temperature of the heat exchanger will only be maintained in periods during which domestic hot water was drawn
on previous days.
Off: (Both LEDs off) The temperature of the heat exchanger is not maintained, as a result of which the delivery of hot tap water takes a
little time. If there is no need for rapid delivery of hot tap water, the DHW comfort function can be switched off.
2 OPERATION AND DISPLAY READ-OUT
Read
-
Operation
1
On / off
A
On / Off button
2
CH operation or setting maximum CH temperature
B
DHW / CH button, for setting desired temperature
3
DHW ope
ration or setting DHW temperature
C
-
button
4
Desired temperature of CH or DHW in °C / Ch water pressure (bar) / Fault code/ Time
D
+ button
5
DHW comfort function eco
E
DHW comfort function off / eco / on
6
DHW comfort function on (continuo
us)
F
Service button
7
Operating code
G
Reset button
8
Flashes to indicate fault
3
2.1 Operating mode on the service display:
—
Off (appliance frost protection active)
3
Ventilate
Wait mode
4
Ignite
0
CH pump post run
5
CH mode
1
Desired temperature reached
6
DHW mode
2
Self test
7
Heat up appliance
Note: When the red LED above the reset key flashes a fault has occurred. A fault code will then appear on the temperature display.
2.2 Changing the settings of the various functions
Keeping the key pressed for 2 seconds takes you to the user settings menu (LED at and the display starts to flash).
Then each time you press the key a different function LED will start to flash. The value of the function can be set using the
and keys. The value set is displayed on the display.
• The reset key closes the settings menu and stores the changes.
• If no key is pressed for 30 seconds, the settings menu is automatically closed and the changes are stored.
• The on/off key closes the settings menu without storing the changes.
• By pressing the button the new times will be stored in the boiler controller. In the display appears [P] for a short period.
. Can be set between 30°C and 90°C (standard setting 80°C). The maximum CH supply temperature
Low setting for moderately cold weather, high setting for colder weather.
DHW temperature.
Can be set between 40°C and 65°C (standard setting 55°C).
All other alterations of settings of the boiler may only be carried out by your installer.
3 START-UP
Once the appliance has been connected to water, gas and electricity supplies and
checked by an authorised installer, the appliance can be started.
Please check the following points:
• The central heating system and domestic hot water system must be well filled and bled.
• The appliance must be switched off (Horizontal dash on service display, other LEDs off).
• The water pressure in the central heating system must be between 1 and 2 bar (Shown on the temperature display).
Never switch the appliance on if the appliance, the CH system and the DHW system have not been completely filled and bled.
• The room thermostat must be set below the temperature in the room.
• The gas tap must be open.
• Switch the appliance on with the on/off key in the display (The LED lights up, and the service display goes out). The appliance
may now heat up for purposes of the DHW system until the heat exchanger reaches the set temperature.
• Set the room thermostat higher than the actual room temperature. The appliance will fire for purposes of the CH system.
4 FAULTS
If the following simple appliance faults occur, they can be resolved as follows. In the case of repeated occurrence or other faults
always notify your installer.
1. The CH system does not heat up or does not become sufficiently warm:
• Increase the temperature setting at the room thermostat.
• Open the radiator valves.
• Increase the CH water temperature setting using the and the and key on the operating panel (see §2).
• Bleed the appliance and installation and check the CH water pressure.
2. The domestic hot water supply does not become hot or hot enough:
• Open the domestic hot water tap further.
• Set the domestic hot water temperature higher using the and the and key on the operating panel (see §2).
3. The fault LED above the reset key is flashing. The following codes are indicated on the display (4):
• 1 The appliance becomes too hot, there is insufficient flow. Open the radiator valves, bleed the appliance and
installation and check the CH water pressure. If necessary top up (see §0 )
• 4 The burner does not light. Consult your installer.
After rectifying the fault press the button and the appliance will start up again. For the meaning of the other operating and reset
fault codes please refer to the installation instructions. If, within a short period the same fault reoccurs your installer has to be
informed and requested to check and/or maintain the boiler.


Produktspezifikationen

Marke: Intergas
Kategorie: Zentralheizungskessel
Modell: Combi Compact ECO RF 36

Brauchst du Hilfe?

Wenn Sie Hilfe mit Intergas Combi Compact ECO RF 36 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Zentralheizungskessel Intergas

Bedienungsanleitung Zentralheizungskessel

Neueste Bedienungsanleitung für -Kategorien-