InfiRay Eye II E3 Plus Bedienungsanleitung

InfiRay Thermometer Eye II E3 Plus

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für InfiRay Eye II E3 Plus (3 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war für 42 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
1. Switch On
Turn on the device by pressing the Power button 2s.
The infrared image comes on, stays on, and the LED
indicator is lighted on.
2.Switch Off
The camera will be switched off by long pressing
the Power button and release the button when the
count down timer change from 3 to 0.
3. Standby Mode
When the device is on, short press the Power button
to enter the standby mode with indicator light flickering.
Short press the Power button again to wake up the device
from the standby mode to the normal mode.
5. Switch the Image Mode
Short press the Image Mode button to switch the image mode
from white hot, black hot, red hot, pseudo color, target highlight
mode circularly.
White Hot Black Hot Red Ho t Pseudo Color Highlight
7. E-Zoom
Short press the E-zoom button for image
zooming from 1×-2×-4× circularly.
10. Hot Spot Tracking
Long press the Image Mode button and
Photo button simultaneously to start
hot spot tracking function and the hottest
objects on the screen can be tracked.
×2/×4
6.Laser Indicator
Long press the Image Mode button to call
out laser indicator, meanwhile the cursor
shows on the display screen indicating the
position of 50 meters away. Long press
the button again to turn off the laser
function, and the cursor is changed to the
user cursor. The user can adjust the cursor
position through the cursor calibration
function in the menu. Long press again to
close the user cursor.
8. Storage
In the normal display mode, short press the Photo button to take
photos and long-pressing for video recording. A video time
prompt box appears in the upper-right corner. Long press again
to quit and save the video.
4. Eyepiece Adjustment
The eyepiece adjustment can help user to get the clearest
image for different eye conditions.
9. Stadiametric Rangefinder
Long press the E-zoom and Image Mode button to turn the
stadiametric rangefinder mode on/off. Then by short or long
pressing the Image Mode button or the Photo button to adjust
the selecting rang of the target. The
distance of human(1.7m target), wild
boar (0.9m target) and hare (0.2m target)
can be measured and displayed behind
the corresponding icon.
11. Setting Menu
Long press the E-zoom button to enter the main menu, then
short press the Image mode button or the Photo button to
toggle up and down. And short press the E-zoom button to
perform following settings: Ultraclear /
Wi-Fi / screen brightness / hue selection
/ calibration mode /analog video / PIP
and more.
When done, long press the E-zoom
button to exit the menu.
12. Ultraclear Mode
In this mode, the image contrast is enhanced, which is suitable
for cloudy, rainy, foggy and other harsh weather conditions.
13. WiFi Function
Turn on WiFi in the main menu, and connect the phone to the
WiFi signal that names Eye_xxxxx-xxxxxx, xxxxx-xxxxxx is the
SN code of the device, and the password is 12345678.
After the WiFi connection is successful, the APP installed on the
phone can be used for real-time operations, such as taking
photos and recording videos.
14. Hue Selection
There are two hues for selections: C (cool) hue and W (warm)
hue. Short press the menu button to switch between C and W.
But the switch between the warm and cool hues is not
applicable to the Color mode.
15. Calibration Mode
Image degradation can be improved by manual correction.
There are two mode available-B(background) and S(shutter),
which can be switched through the main menu.
Press and hold down the E-zoom and Photo button at the
same time to achieve the manual correction.
If the mode B is selected, the lens cover shall be closed during
the correction.
16. Video Out
Turn on the analog video in the main menu, and a video output
icon will appear on the lower right corner of the image. -
The analog video can be output to the monitor with the
specific video transmission cable via the MCX interface.
19. Digital Compass
Short press the E-zoom button to turn the digital compass
on/off.
When is on, the digital compass is displayed in the middle top of
the screen, indicating the current direction.
18. More
Short press the E-zoom button to
enter the secondary menu, including
functions of digital compass / motion
sensor / auto-standby / cursor
calibration / compass calibration /
system information / factory resets /
return to the main menu, etc.
21. Auto Standby
When the auto standby is on, the device will automatically enter
the standby state if there is no operation within 15 minutes, and
power off automatically after 15 minutes in the standby state.
22. Cursor Calibration
In the reticle calibration interface,
short press the E-zoom button to
toggle from all directions. Short press
the image mode button or Photo
button to adjust the reticle position.
When done, long press the E-zoom button to save and exit.
23. System Information
Short press the E-zoom button to
enter the system information interface,
under which user can check all
version information and product code.
24. Factory Resets
Short press the E-zoom button for factory reset. Select (Yes)
or × (No) with a short press of the Image Mode button or Photo
button. Press the E-zoom button
briefly to confirm your selection.
If Yes is selected, the following
settings will be restored to the
factory state:
Image Mode - white hot mode,
Brightness - level 2, - ×1, - S, E-zoom Calibration Mode
Image Hue - warm, and the other functions are off.
Note: Restore factory settings will format memory, so please
save the date in advance.
CO
CO
CO
COCO MP
MP
MP
MPMP ONE
ONE
ONE
ONEONE NT
NT
NT
NTNT S & CO
S & CO
S & CO
S & COS & CO NTR
NTR
NTR
NTRNTR OL
OL
OL
OLOLS
S
S
SS
Eyeshade
Eyepiece Adjustment
Indica to r
Photo
E zoom-
Image Mo de
Power
Laser
Lens
17. Picture in Picture (PIP)
When the PIP function is turned on, a
small window appears at the top
center of the screen, showing a
double zoom of the center area of
the target image.
20. Motion Sensor
Short press the E-zoom button to turn the motion sensor on/off.
The motion sensor will display on the right side of the screen
when it is on.
The horizontal represents the dip
angle, and the vertical represents the
pitch angle.
The values of the current dip angle
and pitch angle are displayed on the bottom of the scale plate.
Eye Ⅱ
V3 .0
IRay Technology Co., Ltd.
Add: 11th Guiyang Street, YEDA, Yantai 264006, P.R. China
Tel: 0086-400-998-3088
Web: www.infirayoutdoor.com
Email: infirayoutdoor@infiray.com
1. The rated charging voltage of this product is 5V, please
charge timely when power is low, so as to avoid the service life
loss caused by battery over-discharge.
2. The thermal imager is not recommended to use in high-
temperature environment for a long time, if the temperature is
too high, the imager will enter the high-temperature protection
state, and automatically shut down.
3. The use of temperature is recommended at -10 C to +50 C ° °
4. Make sure that the USB/MCX port cover on the bottom of the
thermal imager is tightly plugged firstly when using in water
environment, such as rainy days.
5. Under any circumstances (whether on or off), do not expose
the thermal imager directly into the high-intensity radiation
sources (such as the sun, laser, etc.), to avoid irreversible
damage to the device.
6. The B correction mode will reduce the frequency of
automatic shutter correction after the condition of the device
become stable. If the image gets worse, please cover the lens
cover for manual background correction.
7. When the device is not used for a long time, it should be
charged at least 2 months during storage and stored in a dry
and ventilated environment.
8. Do not shine the laser pointer on human eyes.
9. The laser and cursor function depends on the legal
restrictions of different countries and region.
10. Do not be charged in an environment above 40 C.°
A
A
A
AAT
T
T
TTTENTION
TENTION
TENTION
TENTIONTENTION
THERMAL MONOCUL
THERMAL MONOCUL
THERMAL MONOCUL
THERMAL MONOCULTHERMAL MONOCULAR
AR
AR
ARAR
2021.01
QUICK ST
QUICK ST
QUICK ST
QUICK STQUICK ST
ART GUIDE
ART GUIDE
ART GUIDE
ART GUIDEART GUIDE
The laser and cursor function may be disabled due to the legal
restrictions in your countries and regions.
★★ Actual operation time depends on the intensity of WiFi use and the
built-in video recorder.
★★★ Technical parameters of the device may be improved without prior
notice of the customer.
Eye Ⅱ Series
Model
E3Plus
V2.0
E3Max
V2.0
E6+
V2.0
E6Pro
V2.0
Detector
Resolution
384×288
640×480
Pixel Size, um
NETD, mk
Frame Rate, Hz
Objective Lens,
mm
25
35
50
Field of View, °
10.5×7.9
7.5×5.7
12.5×10.0
8.8×7.0
Display
Laser , nm
Magnification,×
2 5~10.
3 5 14 0. ~ .
2 1 8 4. ~ .
3 0 12 0. ~ .
E zoom, ×-
Max Battery.
★★
Life , h
7
6
Weight, g
<450
<520
Dimension, mm
181×65×64
186×65×64
188×65×64
202×65×64
Detection
Range, m
(Target:1.7m×0.5m,
P(n)=99 )%
1298
1818
2597
Eye V2 0 Series.
WeChat Official Account
Official Website
Eye V2.0 Series
25. Charge
When the indicator light is flashing red, it means the battery is
less than 10%, please charge in time. At the same time, there
will be relevant text prompts on the screen.
Open the USB cover at the bottom, plug in the USB charging
cable, and connect with the power to charge, you can also
charge with the power adapter or any other power supply such
as portable power.
The indicator light is orange when charging and green when
full.
When the warning indication of power less than 3% appears on
the display screen, if the device is not charged in time, the
device will automatically shut down after 3s.
26. Data Catching
After connecting the device with the computer via USB cable,
the memory of the device can be read on the computer.


Produktspezifikationen

Marke: InfiRay
Kategorie: Thermometer
Modell: Eye II E3 Plus

Brauchst du Hilfe?

Wenn Sie Hilfe mit InfiRay Eye II E3 Plus benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermometer InfiRay

Bedienungsanleitung Thermometer

Neueste Bedienungsanleitung für -Kategorien-