IFM VSP02A Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für IFM VSP02A (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
Operating instructions
Ex protection related part
Vibration sensor category I M1
VSP02A
80007503/00 06/2018
UK
2
Remarks for safe use in hazardous areas
Functions and features
• Use in hazardous areas according to the classification
I M1
(Group I, category M1, apparatus for mines susceptible to firedamp).
Complies with the requirements of IEC 60079-0:2011 and IEC 60079-11:2011.
• EC type examination certificate
Baseefa12ATEX0247
• IEC Ex type examination certificate
IECEx BAS 12.0132
• Marking (see unit or technical data sheet)
I M1
Ex ia I Ma
(-55 ºC < Ta < +90 ºC)
Certified Temperature Range
-55 °C < Ta < +90 °C
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of types of protection, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (→ "Functions and features" and marking on the unit) is
suitable for the application.
• Connection only to intrinsically safe circuits which are approved with the type examination
certificate and do not exceed the following maximum values:
Ui = 28 V, Ii = 93 mA, Pi = 0.65 W
3
UK
Installation remarks / Installation
• Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
• Protect the units and the cables efficiently against damage.
• Fix the cable directly behind the sensor mounting position.
• For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
Mounting drawing
Non-hazardous area Hazardous area
2
134
+
-
1: Non-hazardous area apparatus
(diagnostic unit)
2: Isolator / Barrier Box
3: Junction box
4: VSP02A
Special conditions for safe operation
The unit must be connected to the external diagnostic unit via a certified isolated barrier.
Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets, type examination certificates and EC declarations of
conformity can be obtained from the manufacturer. Indicate the article number.


Produktspezifikationen

Marke: IFM
Kategorie: Nicht kategorisiert
Modell: VSP02A

Brauchst du Hilfe?

Wenn Sie Hilfe mit IFM VSP02A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert IFM

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-