IFM PV7601 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für IFM PV7601 (11 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/11
Operating instructions
Electronic pressure sensor
for industrial applications
PV76xx
80262454 / 00 03 / 2020
UK
2
1 Preliminary note
Symbols used
â–ºInstructions
→Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
• The device described is a subcomponent for integration into a system.
- The manufacturer is responsible for the safety of the system.
- The system manufacturer undertakes to perform a risk assessment and to
create a documentation in accordance with legal and normative requirements
Contents
1 Preliminary note 2 ...................................................................................................
2 Safety instructions 2 ...............................................................................................
3 Functions and features 3 .......................................................................................
3.1 Applications ...................................................................................................3
3.2 Use in hydraulic systems 4 .............................................................................
4 Function ...............................................................................................................4
4.1 Communication, parameter setting, evaluation 5 .............................................
4.2 Switching function 5 ..........................................................................................
4.3 IO-Link ...........................................................................................................6
5 Installation............................................................................................................6
6 Electrical connection 7 ............................................................................................
7 Parameter setting 8 ................................................................................................
7.1 Parameter setting via PC 8 ...............................................................................
7.2 Parameter setting via the memory plug 8 .........................................................
7.3 List of the parameters 9 ....................................................................................
8 Factory setting 10 ...................................................................................................
3
UK
to be provided to the operator and user of the system. This documentation
must contain all necessary information and safety instructions for the operator,
the user and, if applicable, for any service personnel authorised by the
manufacturer of the system.
• Read this document before setting up the product and keep it during the entire
service life.
• The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
• Only use the product for its intended purpose (→ Functions and features).
• Only use the product for permissible media (→ Technical data).
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
• Installation, electrical connection, set-up, programming, configuration, operation
and maintenance of the product must be carried out by personnel qualified and
authorised for the respective activity.
• Protect units and cables against damage.
3 Functions and features
The device monitors the system pressure of machines and installations.
3.1 Applications
• Type of pressure: relative pressure
Order number Measuring range Pressure rating Bursting pressure
Pressure sensors with 1/4 external thread - 18 NPT
psi bar psi bar psi bar
PV7600 0...5800 0...400 14500 1000 24655 1700
PV7601 0...3625 0...250 9060 625 17400 1200
PV7602 0...1450 0...100 3625 250 14500 1000
PV7623 0...870 0...60 2175 150 13050 900
PV7603 -14.5...360 -1...25 940 65 8700 600
PV7604 -14.5...145 -1...10 360 25 4350 300