Operating instructions
Diffuse reflection sensor
OJ50xx
701396 / 01 07 / 2004
UK
2
Contents
1 Preliminary note....................................................................................................3
1.1 Symbols used .................................................................................................3
2 Function and features ...........................................................................................3
3 Installation ............................................................................................................3
3.1 Installation of the supplied mounting fixture ...................................................4
4 Electrical connection.............................................................................................4
5 Commissioning .....................................................................................................5
6 Settings.................................................................................................................5
6.1 Setting of the sensitivity with stationary objects* ............................................5
6.2 Setting of the sensitivity with moving objects* ................................................6
6.3 Setting of the maximum sensitivity* ................................................................8
6.4 Electronic lock ................................................................................................8
6.5 Programming the output function* ..................................................................8
7 Operation ..............................................................................................................9
8 Maintenance, repair and disposal.........................................................................9
3
UK
1 Preliminary note
1.1 Symbols used
â–ºInstruction
> Reaction, result
→Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
Information
Supplementary note.
2 Function and features
The diffuse reflection sensor detects objects and materials without contact and
indicates their presence by a switched signal.
Range : → type label (value referred to white paper 200 mm x 200 mm).
3 Installation
side sensing* front sensing*
21 1
2
LED1:
push button2:
* In the following sections installation and set-up are described using the example of the type
with front lens. The functions of the units with side lens are identical.
Align the photocell and fasten it to a mounting fixture. â–º
Maximum range is only possible with precise alignment.