Operating instructions
(Ex protection related part)
Inductive sensors
IG / II
80297014 / 00 09 / 2020
UK
UK
UK
UKUK
UK
2
Remarks for safe use in hazardous areas
Functions and features
• Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 60079-0 and EN 60079-31 are met.
• Certificat d‘examen de type:
BVS 20 ATEX E 054 X
• Certificat d‘examen IECEx de type:
IECEx BVS 20.0041X
• Marking (see unit or technical data sheet)
II 3D Ex tc IIIC T80°C Dc X
• Permissible operating temperature of the application (proper usage):
Ta: -20°C...+60°C
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see „Marking“ above and marking on the unit) is suitable
for the application.
Installation remarks / Installation
• Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
• Avoid electrostatic charging on plastic units and cables.
• To avoid electrostatic charging clean the unit with a damp cloth only. Rubbing with non-
conductive materials must be strictly avoided.
• To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, fixing elements, protective housing, etc.).
• Do not mount the unit in the dust flow.
• Avoid dust deposits on the units.
• Protect the units and the cables efficiently against damage.
• For the connections and the electrical characteristics please see the unit marking or the
technical data sheet.
• Avoid direct radiation with high UV components (sunlight). Mount the unit in a protected
place.
• M12 plugs may only be opened or closed in a sufficiently clean environment.
3
• The secure fit of the impact protection housing for the sensor must be checked depending
on the installation conditions (temperature, vibration,...) and at intervals to be defined by
the operator.
Special conditions for safe operation
• The housing and housing parts made of plastic were tested with the supplied impact pro-
tection housing in accordance with EN 60079-0 for group II and for a low mechanical risk
with an impact energy of 4 joules.
• For cable units a sufficient strain relief must be ensured and the cable must be firmly laid.
• For units for which an additional fuse is requested, this fuse must be located outside the
hazardous areas.
• The units must only be operated with the supplied impact protection housing for the
sensor.
24
â–º Screw the impact protection housing onto the sensor manually until the end stop.
â–º Screw the lock nut against the impact protection housing.
â–º Turn the nut against the impact protection housing until the latter also starts to turn. Use
an appropriate spanner.
Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets and EC declarations of conformity can be obtained
from the manufacturer. Indicate the article number.
UK


Produktspezifikationen

Marke: IFM
Kategorie: Nicht kategorisiert
Modell: IG513A

Brauchst du Hilfe?

Wenn Sie Hilfe mit IFM IG513A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert IFM

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-