Installation Instructions
Voltage converter
E30406
704697 / 00 11 / 2009
UK
2
Safety instructions1
Please read this document prior to set-up of the unit. Ensure that the product is •
suitable for your application without any restrictions.
If the operating instructions or the technical data are not adhered to, personal •
injury and/or damage to property can occur.
Functions and features2
The unit provides a 24 V voltage for the supply of sensors in electrical systems
with an operating voltage lower than 24 V.
Electrical connection3
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical
equipment must be adhered to.
Voltage supply according to EN 50178, SELV, PELV.
Disconnect power. â–º
Connect the unit as follows: â–º
4
1
3
2
E30406
4
1
3
2OUT2
L+
L
OUT1
OUT2
OUT1
1 Socket M12 connection to the sensor
2 Plug M12 connection to supply voltage
3
UK
Scale drawing4
58
1 m
1 m
Technical data5
Input voltage [V]..................................................................................................... 9...27 DC
Current consumption max. [mA] ..................................................................................... 500
Sensor supply
Supply voltage [V] .................................................................................................... 24 DC
Operating current max. [mA] ......................................................................................... 125
Materials .................................................................................................... housing: PBT GF
cable: PUR; connector housing: TPU orange;
sealing: Viton; nut: brass nickel-plated
Protection ................................................................................................................ IP 40, III
Ambient temperature [°C] ....................................................................................... -25...70
EMC EN 61000-4-2 ESD: ..................................................................................... 4 / 15 kV
EN 61000-4-3 HF radiated: ................................................. 30 V/m (80...1000 MHz)
EN 61000-4-4 Burst: .................................................................. 2 kV coupling clamp
EN 61000-4-6 HF conducted: .................................................. 10 V (0.15...80 MHz)
Further information at
www.ifm.com Select your country Data sheet direct:→ →


Produktspezifikationen

Marke: IFM
Kategorie: Nicht kategorisiert
Modell: E30406

Brauchst du Hilfe?

Wenn Sie Hilfe mit IFM E30406 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert IFM

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-