IFM E30140 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für IFM E30140 (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
Installation instructions
Siphons
E30140
E30141
UK
80012031 / 00 06 / 2014
2
1 Symbols used
→Cross-reference
Important note
Non-compliance can result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
• Please read this document prior to set-up of the unit. Ensure that the product is
suitable for your application without any restrictions.
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property can occur.
• Improper or non-intended use of the article may lead to unwanted effects in
your application. That is why installation, set-up and maintenance of the article
must only be carried out by qualified personnel authorised by the machine
operator.
• In order to guarantee the correct condition of the device for the operating time it
is necessary to use the device only for media to which the wetted materials are
sufficientlyresistant(→Technicaldata).
• The responsibility whether the devices are suitable for the respective
application lies with the operator. The manufacturer assumes no liability for
consequences of misuse by the operator. Improper installation and use of the
devices results in a loss of the warranty claims.
3 Functions and features
Siphons are used to protect pressure gauges against heating due to hot media:
The extent of the obtained temperature reduction depends on the medium
used. The maximum pressures and temperatures are indicated in the
corresponding data sheets.
3
UK
4 Installation
To prevent material damage and injuries, please note the following:
• To ensure the correct function: Install siphons upwards in a vertical
direction(seedrawingbelow)!
• Installation and removal must be carried out when no pressure is
applied. Even when no pressure is applied, the components can still be
veryhot!
• Note that small quantities of the medium can leak when removing
the device. Therefore: ensure reasonable protection (e.g. protective
gogglesandprotectivegloves)!
Correct installation position:
E30140 E30141
1: The markings show where the left-hand thread begins.
5 Technical data and scale drawing
Technicaldataandscaledrawingatwww.ifm.com→Datasheetsearch→Enter
the article number.
More information at www.ifm.com