Installation Instructions
Welding adapter
G1 / G¾
706013/02 08/2017
UK
UK
UK
UK
UK
2
A
BB
1 2
A: Groove for the O-ring (E30072 only); B: Marking for alignment
Order no. Type Material Pressure rating *
E30009 G¾ - Ø 50mm stainless steel (316S12) 25 bar
E30013 G1 - Ø 50mm stainless steel (316S12) 150 bar
E30060 G1 - Ø 50mm steel (1.0570) 50 bar
E30072 G1 - Ø 50mm stainless steel (316S12) 150 bar
* for the connection sensor - adapter
E30072 is supplied with a Viton O-ring and an EPDM O-ring
Note
• The welding operation must be carried out by authorised personnel.
• It must be carried out carefully and according to state-of-the-art technology.
• During welding and the following cooling phase, neither sensor nor O-ring must
be in place.
• The surfaces must be free from soiling of any kind.
• Welding tools must be suitable for the adapter and wall material.
Preparations
• Bore a hole in the pipe or housing wall with the outside diameter of the adapter
(max. oversize: 0.2 mm).
• If possible, screw a welding mandrel into the adapter
(order no. E30435 for G1 thread, order no. E30071 for G3/4 thread).
3
UK
Welding operation
3 4
â–ºAlign the adapter: Turn the marking to the position provided for the connector /
display of the screwed sensor (see figure 2).
â–ºFix the adapter at several points with sufficient holding force, apply the fixing
points at equal distance opposite each other (see figure 3).
â–ºApply the welding seams between the fixing points opposite each other (see
figure 4). Ensure sufficient intervals between the individual sections (cooling
phases to avoid glowing through / warping of the adapter due to overheating).
The power of the welding device must be adapted to the thickness of the wall.
After welding
â–ºLet the adapter cool down.
â–ºClean the thread from welding residues.
â–ºGrease the thread with lubricating paste.
The paste must be suitable and approved for the application and compatible
with the elastomers used.
â–ºFor the adapter E30072, place one of the supplied O-rings in the groove of the
adapter (Viton or EPDM O-ring, depending on the fluid). It must snap flush into
the groove over its whole circumference (see figure 1).
Note: If the sensor can only be screwed into the thread with great resistance,
apply no force.
If it is not possible to rectify the thread, remove the adapter and weld in a new one.