Installation instructions
Dual sensor
T5
701152 / 02 10 / 2007
UK
UK
UK
UK
UK
2
Function and features
The T5 dual sensor is a slave in the AS-i system (AS-i profile S-7.A.E).
It is designed for use on pneumatic valve actuators. It energises the solenoid of
the pneumatic valve and provides position feedback from the actuator.
Sensor and actuator supply as well as data transfer to the controller via AS-i
2-wire cable.
Watchdog function: If the connection to the master is interrupted for more than
40 ms, the output is switched off (logically 0) when the master messages fail.
Diagnostic information via red LED (short circuit or open circuit).
Operation and display elements
6
7
1 2 3 4
5
8
c
M12-plug
g
standard actuator
d
T5 dual sensor
h
solenoid valve
e
sensor area
i
M12 socket
f
puck
j
AS-i flat cable
•
•
•
3
UK
Installation
Address the T5 dual sensor with an addressing unit, address “0” is set at the
factory. Fasten it to the valve fixings according to the standards (ISO 5211
VDI/VDE).
Connect the solenoid valve to the M12 socket. Only solenoid valves with a
nominal voltage of 24 V and a power of up to max. 1 W may be connected.
i
Modification of a 5/2 valve to 3/2 or vice versa by using the supplied plates.
Data bits
Data bit Type Designation Description
D0 input sensor 1 sensor position 1 damped
D1 input sensor 2 sensor position 2 damped
D2 input error actuator open circuit / short circuit at the actuator
D0 output actuator switch output for solenoid valve
Connection
4
12
3
M12 plug Pin M12 socket Pin
4
1
2
3
AS-i + 1 switch output + 4
AS-i - 3 voltage - 3
Operation
Check the safe functioning of the unit. Display by LEDs.
Red LED is lit: short circuit or open circuit in one output.
Yellow LED is lit: function display (input and output signals are displayed).
•
•