Hubbell J1639T Bedienungsanleitung

Hubbell heater J1639T

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hubbell J1639T (5 Seiten) in der Kategorie heater. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
1
OPERATING AND MAINTENANCE
MANUAL FOR
ELECTRIC BOOSTER HEATER
ELECTRIC HEATER COMPANY
BASE MODEL J
UM ANSI/NSF5
201 Edition7
13
OPTIONAL FIELD CONVERSION FROM SINGLE TO THREE PHASE OR
THREE TO SINGLE PHASE (J6 and J16 models in 6, 7, and 9 kW at 208 and 240
volts and J411 models only)
1. Re-wire the unit to desired configuration as indicated below.
NOTE: The wire to be used for internal wiring must conform to SEW-2 or PTFE
(200°C) and must match the wire size currently in use. Contact the factory for
assistance, if required.
2. Contact the factory for correct labels. The factory will need the serial number for
proper identification.
Single-Phase 3-Phase
OPTIONAL 24-VOLT HEATER INTERLOCK ADAPTER
1. If desired, the heater can be wired to operate only when supplied with a 24-volt signal
through the heater interlock adapter. When no 24-volt signal is supplied through the
heater interlock adapter the heater is interlocked and will not energize. When
interlocked the display will show “ HLd”. The heater will resume normal operation
when a 24-volt signal is re-applied through the heater interlock adapter.
2. To utilize this feature, plug the 24-volt heater interlock adapter into terminal J1 of the
T1000 control board (note: if the XB1 expansion board is used, plug the adapter into
terminal JX3 of the XB1) and verify that the configuration is set to Hon”, see the
controller operation section for further detail. The signal can be either AC or DC.
However, if a DC signal is utilized and the interlock feature does not operate, switch
the two 24-volt supply wires at the heater interlock adapter.
FINAL CHECKS
1. Check all connections for tightness.
2. Ensure that all the above steps are completed.
3. Remove the protective outer plastic covering from the sheet metal shell.
4. After the water is heated for the first time, monitor the water temperature as described
in Section III, Annual Inspection.
J1
To J1
To 24-Volt Si
g
nal
18
Note: Wiring diagrams 3, 5, 6, 7 (NT), 7 (WT), and 11 are obsolete.
1(WT)
L1 L2
J5
J3
J2
Control, Low Water,
& Hi-Limit Probe
Leak Detection Probe
Control
Module &
Display
1(NT)
L1 L2
J5
J3
J2
Control, Low Water,
& Hi-Limit Probe
Leak Detection
Probe
Control
Module &
Display
J8
J8
L1 L2 L3
J5
J3
J2
J8
17
Control
Module &
Display
Control, Low
Water, & Hi-Limit
Probe
Leak
Detection
Probe
10(WT)
L1 L3L2
J5
J3
J2
Control, Low Water,
& Hi-Limit Probe
Leak Detection
Probe
Control
Module &
Display
10(NT)
L1 L3L2
J5
J3
J2
Control, Low Water,
& Hi-Limit Probe Leak
Detection
Probe
Control
Module &
Display
J8
J8
J7
J7
J7
J7
J7
J4
J1
XB1
JX5
JX
4
JX
6

Produktspezifikationen

Marke: Hubbell
Kategorie: heater
Modell: J1639T

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hubbell J1639T benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung heater Hubbell

Bedienungsanleitung heater

Neueste Bedienungsanleitung für -Kategorien-