HP ProLiant DL160 Gen10 Bedienungsanleitung

HP Server ProLiant DL160 Gen10

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für HP ProLiant DL160 Gen10 (139 Seiten) in der Kategorie Server. Dieser Bedienungsanleitung war für 22 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/139
HPE ProLiant DL160 Gen10 Server User
Guide
Part Number: 878591-002
Published: February 2019
Edition: 2
Abstract
This document is for the person who installs, administers, and troubleshoots servers and
storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of
computer equipment and trained in recognizing hazards in products with hazardous energy
levels.
© Copyright 2017–2019 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett
Packard Enterprise products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional warranty.
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained
herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession,
use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer
Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government
under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard
Enterprise website.
Acknowledgments
microSD is a trademark or a registered trademark of SD-3D in the United States, other countries of both.
Microsoft®, Windows®, and Windows Server® are either registered trademarks or trademarks of Microsoft
Corporation in the United States and/or other countries.
Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
Red Hat®
Enterprise Linux is a registered trademark of Red Hat, Inc. in the United States and other
countries.
VMware®
ESXi and VMware vSphere® are registered trademarks or trademarks of VMware, Inc. in the
United States and/or other jurisdictions.
Contents
Important product information.............................................................. 7
Component identification.......................................................................8
Front panel components............................................................................................................... 8
Four-bay LFF drive model..................................................................................................8
Eight-bay SFF drive model with optical drive..................................................................... 8
Eight-bay SFF drive model with two-bay SFF drive backplane option...............................9
Front panel LEDs and buttons...................................................................................................... 9
Four-bay LFF drive model..................................................................................................9
Eight-bay SFF model........................................................................................................11
Power fault LEDs..............................................................................................................12
Rear panel components.............................................................................................................. 13
Rear panel LEDs.........................................................................................................................14
PCIe expansion slot definitions................................................................................................... 15
PCIe slot description................................................................................................................... 15
System board components......................................................................................................... 17
System maintenance switch descriptions........................................................................ 18
Processor, heatsink, and socket components..................................................................19
Drive bay numbering................................................................................................................... 20
Four-bay LFF drive model................................................................................................ 20
Slim SSD numbering (Four-bay LFF drive model only)................................................... 20
Eight-bay SFF drive model with optical drive................................................................... 20
Eight-bay SFF drive model with two-bay SFF drive backplane option............................. 21
Drive LEDs and buttons.............................................................................................................. 21
Low profile LFF drive LED definitions.............................................................................. 21
Hot-plug drive LED definitions..........................................................................................22
NVMe SSD LED definitions..............................................................................................23
NVMe SSD button actions............................................................................................... 24
Fan locations...............................................................................................................................25
Setup...................................................................................................... 26
Optional service.......................................................................................................................... 26
Initial server installation...............................................................................................................26
HPE Installation Service...................................................................................................26
Setting up the server........................................................................................................ 27
Operational requirements........................................................................................................... 30
Space and airflow requirements.......................................................................................30
Temperature requirements............................................................................................... 30
Power requirements......................................................................................................... 31
Electrical grounding requirements....................................................................................31
Server warnings and cautions.....................................................................................................32
Rack warnings.............................................................................................................................32
Electrostatic discharge................................................................................................................ 33
Installing the server into the rack................................................................................................ 33
POST screen options..................................................................................................................34
Operating system........................................................................................................................34
Installing the operating system with Intelligent Provisioning............................................ 35
Installing or deploying an operating system..................................................................... 35
3

Produktspezifikationen

Marke: HP
Kategorie: Server
Modell: ProLiant DL160 Gen10
Installiertes Betriebssystem: Nein
Prozessorhersteller: Intel
Anzahl Prozessorkerne: 8
Breite: 434.594 mm
Tiefe: 614.934 mm
Höhe: 42.926 mm
Anzahl Ethernet-LAN-Anschlüsse (RJ-45): 2
Warentarifnummer (HS): 84714100
Stromversorgung: 500 W
Prozessor-Taktfrequenz: 1.7 GHz
Prozessorfamilie: Intel® Xeon®
Prozessor: 3106
Kompatible Betriebssysteme: Microsoft Windows Server\nRed Hat Enterprise Linux (RHEL)\nSUSE Linux Enterprise Server (SLES)\nOracle Solaris\nVMware
Speicherkapazität: 16 GB
RAID-Unterstützung: Ja
RAID Level: 0, 1,5
USB 3.2 Gen 1 (3.1 Gen 1) Anzahl der Anschlüsse vom Typ A: 3
Gehäusetyp: Rack (1U)
Prozessor-Cache: 11 MB
Konfliktloser-Prozessor: Ja
Prozessor Cache Typ: L3
Prozessor-Code: SR3GL
Prozessor Codename: Skylake
Prozessor Lithografie: 14 nm
Prozessorbetriebsmodi: 64-Bit
Prozessor-Paketgröße: 76.0 x 56.5 mm
Prozessor-Threads: 8
Stepping: U0
Systembus-Rate: - GT/s
Thermal Design Power (TDP): 85 W
Prozessorsockel: LGA 3647 (Socket P)
ARK Prozessorerkennung: 123540
Interner Speichertyp: DDR4-SDRAM
Intel® Turbo-Boost-Technologie: Nein
Eingebettete Optionen verfügbar: Ja
Intel® 64: Ja
Intel® Virtualization Technologie (VT-X): Ja
Anzahl VGA (D-Sub) Anschlüsse: 1
ECC: Ja
RAM-Speicher maximal: 256 GB
Ethernet Schnittstellen Typ: Gigabit Ethernet
HDD Größe: - "
Gesamtspeicherkapazität: 0 GB
Intel® Hyper-Threading-Technik (Intel® HT Technology): Nein
Verbesserte Intel SpeedStep Technologie: Ja
Anzahl installierter Prozessoren: 1
PCI-Express-Slots-Version: 3.0
Maximale Anzahl der PCI-Express-Lanes: 48
Maximaler interner Speicher, vom Prozessor unterstützt: 768 GB
Speichertypen, vom Prozessor unterstützt: DDR4-SDRAM
Speichertaktraten, vom Prozessor unterstützt: 2133 MHz
Prozessorgeneration: Skalierbare Intel® Xeon®
Speichertaktfrequenz: 2400 MHz
Speicherkartensteckplätze: 16x DIMM
Speicherlayout: 1 x 8 GB
Optisches Laufwerk - Typ: Nein
Intel® AES New Instructions (Intel® AES-NI): Ja
Execute Disable Bit: Ja
Intel® Trusted-Execution-Technik: Ja
Skalierbarkeit: 2S
Intel® VT-x mit Extended Page Tables (EPT): Ja
Intel® TSX-NI: Ja
Intel® Virtualisierungstechnik für direkte I/O (VT-d): Ja
Intel® TSX-NI-Version: 1.00
Tcase: 77 °C
Maximale unterstützte Anzahl der HDD: 4
Unterstützung für redundantes Netzteil: Nein
Anzahl der Haupt-Netzteile: 1
PCI-Express x8 (Gen 3.x)-Anschlüsse: 3
Max. Speicherkapazität: 8 TB
Unterstützte Hard-Disk Drive Größen: 3.5 "
Ethernet/LAN: Ja

Brauchst du Hilfe?

Wenn Sie Hilfe mit HP ProLiant DL160 Gen10 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Server HP

Bedienungsanleitung Server

Neueste Bedienungsanleitung für -Kategorien-