HPE ProLiant DL160 Gen10 Server User
Guide
Part Number: 878591-002
Published: February 2019
Edition: 2
Abstract
This document is for the person who installs, administers, and troubleshoots servers and
storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of
computer equipment and trained in recognizing hazards in products with hazardous energy
levels.
© Copyright 2017–2019 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett
Packard Enterprise products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional warranty.
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained
herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession,
use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer
Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government
under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard
Enterprise website.
Acknowledgments
microSD is a trademark or a registered trademark of SD-3D in the United States, other countries of both.
Microsoft®, Windows®, and Windows Server® are either registered trademarks or trademarks of Microsoft
Corporation in the United States and/or other countries.
Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
Red Hat®
Enterprise Linux is a registered trademark of Red Hat, Inc. in the United States and other
countries.
VMware®
ESXi™ and VMware vSphere® are registered trademarks or trademarks of VMware, Inc. in the
United States and/or other jurisdictions.
Contents
Important product information.............................................................. 7
Component identification.......................................................................8
Front panel components............................................................................................................... 8
Four-bay LFF drive model..................................................................................................8
Eight-bay SFF drive model with optical drive..................................................................... 8
Eight-bay SFF drive model with two-bay SFF drive backplane option...............................9
Front panel LEDs and buttons...................................................................................................... 9
Four-bay LFF drive model..................................................................................................9
Eight-bay SFF model........................................................................................................11
Power fault LEDs..............................................................................................................12
Rear panel components.............................................................................................................. 13
Rear panel LEDs.........................................................................................................................14
PCIe expansion slot definitions................................................................................................... 15
PCIe slot description................................................................................................................... 15
System board components......................................................................................................... 17
System maintenance switch descriptions........................................................................ 18
Processor, heatsink, and socket components..................................................................19
Drive bay numbering................................................................................................................... 20
Four-bay LFF drive model................................................................................................ 20
Slim SSD numbering (Four-bay LFF drive model only)................................................... 20
Eight-bay SFF drive model with optical drive................................................................... 20
Eight-bay SFF drive model with two-bay SFF drive backplane option............................. 21
Drive LEDs and buttons.............................................................................................................. 21
Low profile LFF drive LED definitions.............................................................................. 21
Hot-plug drive LED definitions..........................................................................................22
NVMe SSD LED definitions..............................................................................................23
NVMe SSD button actions............................................................................................... 24
Fan locations...............................................................................................................................25
Setup...................................................................................................... 26
Optional service.......................................................................................................................... 26
Initial server installation...............................................................................................................26
HPE Installation Service...................................................................................................26
Setting up the server........................................................................................................ 27
Operational requirements........................................................................................................... 30
Space and airflow requirements.......................................................................................30
Temperature requirements............................................................................................... 30
Power requirements......................................................................................................... 31
Electrical grounding requirements....................................................................................31
Server warnings and cautions.....................................................................................................32
Rack warnings.............................................................................................................................32
Electrostatic discharge................................................................................................................ 33
Installing the server into the rack................................................................................................ 33
POST screen options..................................................................................................................34
Operating system........................................................................................................................34
Installing the operating system with Intelligent Provisioning............................................ 35
Installing or deploying an operating system..................................................................... 35
3
Produktspezifikationen
Marke: | HP |
Kategorie: | Server |
Modell: | ProLiant DL160 Gen10 |
Installiertes Betriebssystem: | Nein |
Prozessorhersteller: | Intel |
Anzahl Prozessorkerne: | 8 |
Breite: | 434.594 mm |
Tiefe: | 614.934 mm |
Höhe: | 42.926 mm |
Anzahl Ethernet-LAN-Anschlüsse (RJ-45): | 2 |
Warentarifnummer (HS): | 84714100 |
Stromversorgung: | 500 W |
Prozessor-Taktfrequenz: | 1.7 GHz |
Prozessorfamilie: | Intel® Xeon® |
Prozessor: | 3106 |
Kompatible Betriebssysteme: | Microsoft Windows Server\nRed Hat Enterprise Linux (RHEL)\nSUSE Linux Enterprise Server (SLES)\nOracle Solaris\nVMware |
Speicherkapazität: | 16 GB |
RAID-Unterstützung: | Ja |
RAID Level: | 0, 1,5 |
USB 3.2 Gen 1 (3.1 Gen 1) Anzahl der Anschlüsse vom Typ A: | 3 |
Gehäusetyp: | Rack (1U) |
Prozessor-Cache: | 11 MB |
Konfliktloser-Prozessor: | Ja |
Prozessor Cache Typ: | L3 |
Prozessor-Code: | SR3GL |
Prozessor Codename: | Skylake |
Prozessor Lithografie: | 14 nm |
Prozessorbetriebsmodi: | 64-Bit |
Prozessor-Paketgröße: | 76.0 x 56.5 mm |
Prozessor-Threads: | 8 |
Stepping: | U0 |
Systembus-Rate: | - GT/s |
Thermal Design Power (TDP): | 85 W |
Prozessorsockel: | LGA 3647 (Socket P) |
ARK Prozessorerkennung: | 123540 |
Interner Speichertyp: | DDR4-SDRAM |
Intel® Turbo-Boost-Technologie: | Nein |
Eingebettete Optionen verfügbar: | Ja |
Intel® 64: | Ja |
Intel® Virtualization Technologie (VT-X): | Ja |
Anzahl VGA (D-Sub) Anschlüsse: | 1 |
ECC: | Ja |
RAM-Speicher maximal: | 256 GB |
Ethernet Schnittstellen Typ: | Gigabit Ethernet |
HDD Größe: | - " |
Gesamtspeicherkapazität: | 0 GB |
Intel® Hyper-Threading-Technik (Intel® HT Technology): | Nein |
Verbesserte Intel SpeedStep Technologie: | Ja |
Anzahl installierter Prozessoren: | 1 |
PCI-Express-Slots-Version: | 3.0 |
Maximale Anzahl der PCI-Express-Lanes: | 48 |
Maximaler interner Speicher, vom Prozessor unterstützt: | 768 GB |
Speichertypen, vom Prozessor unterstützt: | DDR4-SDRAM |
Speichertaktraten, vom Prozessor unterstützt: | 2133 MHz |
Prozessorgeneration: | Skalierbare Intel® Xeon® |
Speichertaktfrequenz: | 2400 MHz |
Speicherkartensteckplätze: | 16x DIMM |
Speicherlayout: | 1 x 8 GB |
Optisches Laufwerk - Typ: | Nein |
Intel® AES New Instructions (Intel® AES-NI): | Ja |
Execute Disable Bit: | Ja |
Intel® Trusted-Execution-Technik: | Ja |
Skalierbarkeit: | 2S |
Intel® VT-x mit Extended Page Tables (EPT): | Ja |
Intel® TSX-NI: | Ja |
Intel® Virtualisierungstechnik für direkte I/O (VT-d): | Ja |
Intel® TSX-NI-Version: | 1.00 |
Tcase: | 77 °C |
Maximale unterstützte Anzahl der HDD: | 4 |
Unterstützung für redundantes Netzteil: | Nein |
Anzahl der Haupt-Netzteile: | 1 |
PCI-Express x8 (Gen 3.x)-Anschlüsse: | 3 |
Max. Speicherkapazität: | 8 TB |
Unterstützte Hard-Disk Drive Größen: | 3.5 " |
Ethernet/LAN: | Ja |
Brauchst du Hilfe?
Wenn Sie Hilfe mit HP ProLiant DL160 Gen10 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Server HP
1 Oktober 2024
30 August 2024
15 August 2024
31 Juli 2024
27 Juli 2024
24 Juli 2024
22 Juli 2024
15 Juli 2024
4 Juli 2024
Bedienungsanleitung Server
- Server Acer
- Server Asus
- Server Gigabyte
- Server Medion
- Server Sony
- Server ZyXEL
- Server Buffalo
- Server Allnet
- Server Linksys
- Server Netgear
- Server Fantec
- Server Technics
- Server Abus
- Server Megasat
- Server Toshiba
- Server Lindy
- Server Dell
- Server Lenovo
- Server Tripp Lite
- Server TRENDnet
- Server Western Digital
- Server AVerMedia
- Server Veritas
- Server Black Box
- Server Supermicro
- Server SilverStone
- Server NEC
- Server Monacor
- Server Seagate
- Server Fujitsu
- Server Maxdata
- Server Revox
- Server Totolink
- Server Conceptronic
- Server D-Link
- Server QNAP
- Server Digitus
- Server LevelOne
- Server APC
- Server Cisco
- Server Freecom
- Server Synology
- Server Kramer
- Server Intellinet
- Server Eaton
- Server Hikvision
- Server FLIR
- Server ELAC
- Server Planet
- Server Asustor
- Server Blackmagic Design
- Server Dane Elec
- Server Digi
- Server Dual Bay
- Server EMC
- Server GeoVision
- Server Ibm
- Server In Win
- Server Iomega
- Server LaCie
- Server Provision ISR
- Server Quantum
- Server Sun
- Server AMX
- Server ACTi
- Server Vimar
- Server Siig
- Server Intel
- Server Moxa
- Server StarTech.com
- Server Smart-AVI
- Server Mobotix
- Server Sonnet
- Server SEH
- Server Gefen
- Server Avocent
- Server Atlantis Land
- Server Hanwha
- Server ATen
- Server KanexPro
- Server Axis
- Server Advantech
- Server HGST
- Server Kiloview
- Server B&B Electronics
- Server Extron
- Server Atlona
- Server Rocstor
- Server Raidsonic
- Server G-Technology
- Server Infortrend
- Server Areca
- Server Silex
- Server Promise Technology
- Server Matrox
- Server Origin Storage
- Server Ernitec
- Server EXSYS
- Server Raritan
- Server C2G
- Server Chenbro Micom
- Server Lantronix
- Server IStarUSA
- Server Valcom
- Server TAIDEN
- Server MvixUSA
- Server Opengear
- Server Mr. Signal
- Server NETSCOUT
Neueste Bedienungsanleitung für -Kategorien-
13 Oktober 2024
12 Oktober 2024
12 Oktober 2024
11 Oktober 2024
11 Oktober 2024
10 Oktober 2024
6 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024