Honeywell YZ667A1060 Bedienungsanleitung
Honeywell
Temperaturregeln
YZ667A1060
Lesen Sie kostenlos die đ deutsche Bedienungsanleitung fĂźr Honeywell YZ667A1060 (12 Seiten) in der Kategorie Temperaturregeln. Dieser Bedienungsanleitung war fĂźr 35 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/12
1
Wireless Domestic Heating Zoning System
INSTALLATION GUIDE
YZ A667 1060
TABLE OF CONTENTS
Section Page
1 General .................................................. 1
2 Technical Information .......................... 1
3 Factory ConďŹguration .......................... 2
4 HC60NG Relay Module ......................... 3
5 CM67z Room Unit ................................. 4
6 HR80UK Radiator Controller ............... 5
7 System Testing ..................................... 6
7.1 Service mode ......................................................6
8 Changing the ConďŹguration ................ 7
8.1 Parameters of the CM67z ...................................7
8.2 Changing or adding a HR80UK to a zone ........8
8.3 Built -in sensor conďŹguration ........................... 9
8.4 Adding a HC60NG Zone valve controller .........9
8.5 Resetting a Bound HR80UK .............................. 9
9 Trouble Shooting ................................ 10
9.1 Trouble Shooting Guide ...................................10
9.2 Manual adaption ............................................... 11
9.3
Def (default setting) and Full operating modes
...11
9.4 Resetting the HR 80 to the factory settings ...11
1 GENERAL
The CM Zone Wireless Domestic Heating Zoning System
offers high levels of comfort and energy savings for the
home. It provides the ability to control two individual zones
at different comfort levels and at different times. A typical
example being the living areas and the bedrooms being
controlled separately.
The standard CM Zone Pack contains a Room Unit, a Relay
Module and six Radiator Controllers all pre-bound with three
Radiator Controllers bound to Zone 1 and three bound to
Zone 2. The System can be expanded or modiďŹed and the
methods used are described within this Guide.
To get the best from the installed system it is recommended
to use Honeywell VT15, VT117 or VT200 TRV bodies and a
Honeywell DU145 Automatic Bypass Valve.
For application support please contact your nearest
Honeywell salesman, for technical assistance please contact
the Honeywell Technical Help Desk, details are on the back
page.
HC60NG Relay Module CM67z Room Unit
HR80UK Radiator Controllers
42010824-003 R3
2 TECHNICAL INFORMATION
Type numbers
CM67z - Room Unit (x1)
HR80UK - Radiator Controller (x6)
HC60NG - Relay module (x1)
Material
Housings made of plastics (ABS).
Dimensions
CM67z - 155 x 105 x 30 mm. (l x h x d)
HR80UK - 50 x 80 x 105 mm. (l x h x d)
HC60NG - 131 x 97 x 36 mm. (l x h x d)
Power
CM67z - 2 x 1.5 V IEC LR6 (AA) Alkaline cells
HR80UK - 2 x 1.5 V IEC LR6 (AA) Alkaline cells
HC60NG - 230V~ 50Hz powered
Electrical wiring (only for HC60NG)
Mains power supply
Relay output rating: 24-230 V~, 10A resistive,
3A inductive 0.6 p.f.
Programming Capability
2 individual heating programs
7 days with 6 temperature change times per day
Approvals
DIN EN ISO 9001/14001, CE, EN60730-1 (2000),
EN60730-2-9 (2002), EN55014-1 (2000), EN55014-2 (1997),
ETSI EN300 220-3 (2000), ETSI EN301 489-3 (2000)
2
Section 3: Factory ConďŹguration
Zoning Example
Zone 1: Living Room + Kitchen (downstairs)
Zone 2: Bedrooms (upstairs)
Zone 1
Zone 2
The Hydronic Zoning kit is factory pre-conďŹgured and has the
following components:
⢠Zone 1 - Three HR80UK Radiator controllers labelled 1
⢠Zone 2 - Two HR80UK Radiator controllers labelled 2
⢠HC60NG - Relay box
⢠CM67z - Room Unit
To change this factory conďŹguration or to add components
please see Section 8: Changing the ConďŹguration.
A typical traditional system with open
vented hot water storage tank
Conventional Boilers
These are used in traditional central
heating systems in the UK.
A typical COMBI system
Combination Boilers
With a combination boiler,
hot water and central heating
requirements are provided
from the one unit.
3
5 6
3 4
1
The HC60NG is a radio frequency (RF) device and for the best perform-
ance should be installed in an open space. Leave at least 30cm distance
from any metal objects including wall boxes and the boiler.
2
NOTE:
The HC60NG contains no user serviceable parts. It should be opened and
installed by qualiďŹed installer only.
WARNING:
Electrostatic sensitive device! Do not touch the circuit board.
> 7mm
< 7mm
1.0-2.5mm²
6mm max.
NOTE:
Install in accordance with local wiring regulations
CAUTION:
Observe ambient temperature and current limits (see HC60NG wiring label)
Section 4:
HC60NG Relay Module
Caution!
!When selecting the operating site of the HC60NG ensure that the dis-
tance to other wireless devices such as wireless headphones, cordless
phones etc. is at least 1-2m.
The HC60NG Relay Module is an integral part of the CM Zone Control System. It is
designed to control a Domestic Boiler, Valve, pump or Electric Heating appliances.
In the standard CM Zone Pack the HC60NG Relay Module is conďŹgured to control a Boiler
based upon demand signals received from the HR80UK Radiator Controllers either directly
or via a âY Planâ / âS Planâ connection described below.
For control of other applications see Section 8: Changing the ConďŹguration.
Please note: Maximum wire size 2.5mm2. SPDT relay suitable for
24...230V~, 10A resistive, 3A inductive
Honeywell âY Planâ Connections Honeywell âS Planâ Connections
NOTE:
For existing âY Planâ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
NOTE:
For existing âS Planâ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
HC60NG Relay Module
Typical Burner / Boiler connections
a. Burner (direct control)
HC60NG
b. Combi boiler
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical âY Planâ Junction Box
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical âS Planâ Junction Box
HC60NG
Produktspezifikationen
Marke: | Honeywell |
Kategorie: | Temperaturregeln |
Modell: | YZ667A1060 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Honeywell YZ667A1060 benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Temperaturregeln Honeywell
30 Dezember 2023
25 November 2023
5 November 2023
5 November 2023
3 November 2023
11 September 2023
8 Juli 2023
16 Mai 2023
24 April 2023
24 April 2023
Bedienungsanleitung Temperaturregeln
- Temperaturregeln Panasonic
- Temperaturregeln AEG
- Temperaturregeln Techno Line
- Temperaturregeln Technoline
- Temperaturregeln Ventus
- Temperaturregeln Kathrein
- Temperaturregeln Dimplex
- Temperaturregeln JUNG
- Temperaturregeln Carel
- Temperaturregeln Fluke
- Temperaturregeln AstralPool
- Temperaturregeln SRS
- Temperaturregeln Emko
- Temperaturregeln Jumo
Neueste Bedienungsanleitung fĂźr -Kategorien-
28 Mai 2024
28 Mai 2024
24 Mai 2024
3 Mai 2024
9 April 2024
31 März 2024
13 März 2024
7 März 2024
24 Februar 2024
21 Februar 2024