Honeywell RPLS730B1000 Bedienungsanleitung

Honeywell Schalter RPLS730B1000

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Honeywell RPLS730B1000 (12 Seiten) in der Kategorie Schalter. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
INSTALLATION AND USER GUIDE
69-2457EFS-05
RPLS730B / RPLS731B
Programmable Wall Switch
APPLICATIONS
The RPLS730B / RPLS731B programmable wall switch has been designed to
control lightings and motors:
INSTALLATION
NOTE: This switch cannot be used if there are not at least 2 white wires joined
by a connector inside the electrical box.
1. Cut power at the circuit breaker to avoid electric shock.
2. Remove the existing switch.
3. Install the new switch as shown in the diagram below.
4. Apply power at the circuit breaker.
Load type Maximum load Examples
Resistive load 2400 W (20 A @ 120 V) •incandescent lights
•halogen lights
•block heater
Inductive load 2400 W (20 A @ 120 V) •fluorescent lights
•compact fluorescent lights (CFL)
•sodium lamps
•electronic ballasts
Motor 1 hp •pool filter pumps
•fans
M38497
120 VAC (line)
blue (load)
white (neutral)
Load
black (line)
RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
69-2457EFS—05 2
POWER-ON
1. Pry the switch door open from the bottom
using a small screwdriver.
2. Ensure the ON/OFF selector is set to ON.
3. 0:00Reset the switch using a paper clip. will
flash.
If the display is blank:
• Ensure the ON/OFF selector is properly
engaged in the ON position. Push it to the right
using a small screwdriver.
• At first power-up after the installation, the
screen of the switch may be blank or dim, or
become so when you turn the light on. However,
during that time, the switch is fully functional. Wait 2 minutes for the
switch’s built-in battery to be sufficiently charged and the screen will
return to its normal contrast.
SETTING THE CLOCK
NOTE: The switch displays the time in 24-hour format by default or follow-
ing a reset.
1. To change to 12-hour format (or vice versa), proceed as follows:
• Press one of the control buttons to ensure the MAN or AUTO
indicator is displayed.
• Press the MIN and HOUR buttons simultaneously and briefly (0:00
display = 24-hour, 12:00 display = 12-hour).
2. Set the time using the HOUR and MIN buttons. If you have selected
the 12-hour format, ensure that PM appears on the screen when an
afternoon time is displayed.
3. Set the day using the DAY button.
4. Press one of the control buttons or close the switch door to return to
normal operation.
SELECTING THE OPERATING MODE
The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO). To switch mode, press the switch door for 3 seconds.
Manual mode
The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode ( ) and state (MAN ON or OFF) are displayed.
Automatic mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed. To temporarily
override the programmed schedule, briefly press the
switch door. The new state (ON or OFF) will flash to show
that this state is temporary. The override remains in effect
until you press the switch door again or until the beginning of the next
program.
M38498
Reset
Control (4)
On/Off selector
M38499
RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
3 69-2457EFS—0 5
PROGRAMMING THE SCHEDULE
You can set up to 7 programs. To set a program, you need to enter its start
time (ON) and its end time (OFF).
1. Pry the switch door open using a small screwdriver.
2. Press the PGM button to display a program and its
On or Off time. For example, when you first press
PGM, program number 1 (P1) and its On time (ON)
will appear. - : - - will appear instead of the time if the
program is not set (inactive).
3. Press the DAY button to select the day to which you
want to apply the program.
4. NOTE: If you want to apply the program to every day
of the week, press DAY until all the days are
displayed. (This still counts as 1 program, not 7)
5. Press the buttons to set the HOUR and MIN ON time
(time when you want the lights to turn on). If you have selected the 12-
hour format, ensure that PM appears on the screen when an afternoon
time is displayed.
6. After you have programmed the ON time, press the PGM button to
display the OFF time (time when you want the lights
to turn off).
7. Repeat steps 3 through 5 to program the OFF time. If
the program ON time is set for every day of the week,
the program OFF time will automatically be set for
every day.
8. To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
9. Press one of the control buttons or close the switch door to return to
normal operation.
Clearing a programmed time
Press the PGM button as many times as needed to display the programmed
time. Hold the PGM button for 3 seconds. - : - - appears when the
programmed time is erased.
TROUBLESHOOTING
Blank display •Verify circuit breaker at main panel.
•Ensure the ON/OFF ON selector is at .
•Reset the switch using a paper clip.
Faded or irregular display Ambient temperature below freezing point
Cannot switch between 24-hour
format and 12-hour format
First, press one of the control buttons so that
MAN or AUTO appears on display.
Programs do not run as expected •Make sure the switch is properly programmed.
•Note that - : - - indicates an inactive program.
•If the switch has been configured for 12-hour
format, check that PM appears on the left side of
the screen when an afternoon time is displayed.
The switch resets itself without
apparent reason when used to control
an inductive load such as a relay or a
contactor.
The reset is caused by the load. Install a snubber
(AC130-03) at each relay/contactor.
M38500
M38501


Produktspezifikationen

Marke: Honeywell
Kategorie: Schalter
Modell: RPLS730B1000

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell RPLS730B1000 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalter Honeywell

Bedienungsanleitung Schalter

Neueste Bedienungsanleitung für -Kategorien-