Honeywell HC60NG Bedienungsanleitung


Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Honeywell HC60NG (12 Seiten) in der Kategorie Temperaturkontrolle. Dieser Bedienungsanleitung war fĆ¼r 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
1
Wireless Domestic Heating Zoning System
INSTALLATION GUIDE
YZ667A1060
TABLE OF CONTENTS
Section Page
1 General .................................................. 1
2 Technical Information .......................... 1
3 Factory Conļ¬guration .......................... 2
4 HC60NG Relay Module ......................... 3
5 CM67z Room Unit ................................. 4
6 HR80UK Radiator Controller ............... 5
7 System Testing ..................................... 6
7.1 Service mode ......................................................6
8 Changing the Conļ¬guration ................ 7
8.1 Parameters of the CM67z ...................................7
8.2 Changing or adding a HR80UK to a zone ........8
8.3 Built -in sensor conļ¬guration ...........................9
8.4 Adding a HC60NG Zone valve controller .........9
8.5 Resetting a Bound HR80UK ..............................9
9 Trouble Shooting ................................ 10
9.1 Trouble Shooting Guide ...................................10
9.2 Manual adaption ...............................................11
9.3
Def (default setting) and Full operating modes
...11
9.4 Resetting the HR 80 to the factory settings ...11
1 GENERAL
The CM Zone Wireless Domestic Heating Zoning System
offers high levels of comfort and energy savings for the
home. It provides the ability to control two individual zones
at different comfort levels and at different times. A typical
example being the living areas and the bedrooms being
controlled separately.
The standard CM Zone Pack contains a Room Unit, a Relay
Module and six Radiator Controllers all pre-bound with three
Radiator Controllers bound to Zone 1 and three bound to
Zone 2. The System can be expanded or modiļ¬ed and the
methods used are described within this Guide.
To get the best from the installed system it is recommended
to use Honeywell VT15, VT117 or VT200 TRV bodies and a
Honeywell DU145 Automatic Bypass Valve.
For application support please contact your nearest
Honeywell salesman, for technical assistance please contact
the Honeywell Technical Help Desk, details are on the back
page.
HC60NG Relay Module CM67z Room Unit
HR80UK Radiator Controllers
42010824-003 R3
2 TECHNICAL INFORMATION
Type numbers
CM67z - Room Unit (x1)
HR80UK - Radiator Controller (x6)
HC60NG - Relay module (x1)
Material
Housings made of plastics (ABS).
Dimensions
CM67z - 155 x 105 x 30 mm. (l x h x d)
HR80UK - 50 x 80 x 105 mm. (l x h x d)
HC60NG - 131 x 97 x 36 mm. (l x h x d)
Power
CM67z - 2 x 1.5 V IEC LR6 (AA) Alkaline cells
HR80UK - 2 x 1.5 V IEC LR6 (AA) Alkaline cells
HC60NG - 230V~ 50Hz powered
Electrical wiring (only for HC60NG)
Mains power supply
Relay output rating: 24-230 V~, 10A resistive,
3A inductive 0.6 p.f.
Programming Capability
2 individual heating programs
7 days with 6 temperature change times per day
Approvals
DIN EN ISO 9001/14001, CE, EN60730-1 (2000),
EN60730-2-9 (2002), EN55014-1 (2000), EN55014-2 (1997),
ETSI EN300 220-3 (2000), ETSI EN301 489-3 (2000)
2
Section 3: Factory Conļ¬guration
Zoning Example
Zone 1: Living Room + Kitchen (downstairs)
Zone 2: Bedrooms (upstairs)
Zone 1
Zone 2
The Hydronic Zoning kit is factory pre-conļ¬gured and has the
following components:
ā€¢ Zone 1 - Three HR80UK Radiator controllers labelled 1
ā€¢ Zone 2 - Two HR80UK Radiator controllers labelled 2
ā€¢ HC60NG - Relay box
ā€¢ CM67z - Room Unit
To change this factory conļ¬guration or to add components
please see Section 8: Changing the Conļ¬guration.
A typical traditional system with open
vented hot water storage tank
Conventional Boilers
These are used in traditional central
heating systems in the UK.
A typical COMBI system
Combination Boilers
With a combination boiler,
hot water and central heating
requirements are provided
from the one unit.
3
5 6
3 4
1
The HC60NG is a radio frequency (RF) device and for the best perform-
ance should be installed in an open space. Leave at least 30cm distance
from any metal objects including wall boxes and the boiler.
2
NOTE:
The HC60NG contains no user serviceable parts. It should be opened and
installed by qualiļ¬ed installer only.
WARNING:
Electrostatic sensitive device! Do not touch the circuit board.
> 7mm
< 7mm
1.0-2.5mmĀ²
6mm max.
NOTE:
Install in accordance with local wiring regulations
CAUTION:
Observe ambient temperature and current limits (see HC60NG wiring label)
Section 4:
HC60NG Relay Module
Caution!
!When selecting the operating site of the HC60NG ensure that the dis-
tance to other wireless devices such as wireless headphones, cordless
phones etc. is at least 1-2m.
The HC60NG Relay Module is an integral part of the CM Zone Control System. It is
designed to control a Domestic Boiler, Valve, pump or Electric Heating appliances.
In the standard CM Zone Pack the HC60NG Relay Module is conļ¬gured to control a Boiler
based upon demand signals received from the HR80UK Radiator Controllers either directly
or via a ā€˜Y Planā€™ / ā€˜S Planā€™ connection described below.
For control of other applications see Section 8: Changing the Conļ¬guration.
Please note: Maximum wire size 2.5mm2. SPDT relay suitable for
24...230V~, 10A resistive, 3A inductive
Honeywell ā€˜Y Planā€™ Connections Honeywell ā€˜S Planā€™ Connections
NOTE:
For existing ā€™Y Planā€™ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
NOTE:
For existing ā€™S Planā€™ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
HC60NG Relay Module
Typical Burner / Boiler connections
a. Burner (direct control)
HC60NG
b. Combi boiler
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical ā€˜Y Planā€™ Junction Box
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical ā€˜S Planā€™ Junction Box
HC60NG


Produktspezifikationen

Marke: Honeywell
Kategorie: Temperaturkontrolle
Modell: HC60NG

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell HC60NG benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Temperaturkontrolle Honeywell

Bedienungsanleitung Temperaturkontrolle

Neueste Bedienungsanleitung fĆ¼r -Kategorien-