Hikvision DS-PDSMK-S-WB Bedienungsanleitung

Hikvision Alarmanlage DS-PDSMK-S-WB

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hikvision DS-PDSMK-S-WB (9 Seiten) in der Kategorie Alarmanlage. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/9
1Appearance
T
E
S
T
/
H
U
S
H
Test/Hush Buon
Indicator
Coding Buon
Power Switch
DS-PDSMK-S-WB
Wireless Photoelectric Smoke Detector
Diagram References
E N G L I S H
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, the RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery, that can result in an
explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked
with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recy-
clethis.info
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the
case of some lithium baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery,
that can result in an explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the
leakage of flammable liquid or gas
The addional force shall be equal to three mes the weight of the
equipment but not less than 50N. The equipment and its
associated mounng means shall remain secure during the
installaon. Aer the installaon, the equipment, including any
associated mounng plate, shall not be damaged.
INSTALLATION CAUTION
BATTERY CAUTION
Chemical burning danger
Do not swallow the baery.
Keep new and used baeries away from the children.
If you think baeries might have been swallowed or placed inside any part of the
body, seek immediate medical aenon.
Risk of explosion if baery is replaced by an incorrect type.
Replacement of a baery with an incorrect type that can defeat a safeguard.
Dispose of used baeries according to the instrucons and local regulaon.
If the baery compartment does not close securely, stop using the product and keep it away from children.
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful
interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
2
Audible and Visual Alarm Indicators
When operang normally, a red LED adjacent to the Test buon will flash every 320 s. When smoke is detected, an internal sounder will acvate to alert occupants, and
the LED will flash rapidly. The sounder is a loud, pulsang alarm and produces a repeang Temporal 3 audible signal paern (0.5 s on, 0.5 s off for 3 cycles, followed by
1.5 s off, repeang).
Test/Hush BuonWhen there is no alarm present, hold the Test/Hush buon will acvate the smoke alarm to check its operaon. The alarm will sound and the LED will
flash rapidly. The unit will return to normal condion in about 10 s when the test is completed.
When the smoke alarm is in the Alarm condion, press the Test/Hush buon will hush the smoke alarm for approximately 11 min. The Hush feature should only be
used aer the cause of the alarm is known (such as normal cooking fumes). The Hush feature allows me for the smoke to clear. During the hush me, the LED will flash
twice every second. Aer the Hush me has expired, the smoke alarm will return to normal sensivity. If smoke is sll present in the unit, the alarm will re-acvate. The
Hush feature can be used repeatedly.
Smoke Chamber Fault
The detector monitors the condion of the smoke sensing chamber. If the smoke sensing chamber ceases to operate normally, the smoke alarm will emit a short
audible signal, then followed by a single Red LED indicator flash, repeang every 40 s. In this case, try vacuuming clean the detector to remove dust. If the condion
persists, replace the detector with a new unit.
Low Baery
When the baery is depleted, the detector will emit a short audible signal and the Red LED indicator flash, repeang every 40 s for at least 30 days. Interconnected
detector will also emit two short audible signals and the Red LED indicator will flash twice, repeang every 4 hours. When the Low Baery signal is given, replaced the
detector with a new unit.
Interconnecon
Wireless interconnecon allows up to 12 detectors to be connected together. Interconnected detector will acvate sounders on all units if any smoke alarm detector. In
this case, only the detector that detected smoke will flash the Red LED. This allows the home owner to quickly locate the cause of the alarm.
Local alarm memory
Aer alarm occurs, the green LED gives 3 flashes every 40 s up to 24 h, which stops flashing aer 24 hours. Any me before the next alarm, press the Test buon, the
detector shall emit 3 audible beeps every 1 s. Release of the Test buon shall reset the alarm.
Funcon
3Enrollment
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Enter“Sengs-System Sengs” , and tap the "Enrollment Mode" buon to make the AX PRO enter the enrollemnt status.
4. Turn the power switch of the peripheral on to enrolled it to the control panel.
Enroll the Detector Locally
Register the Detector via APP
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Tap the “+” icon on the boom of the page, and scan the QR code to add the peripheral.
4. Turn the power switch of the peripheral on, and it will be automacally enrolled to the control panel.
1
2
xxxx
Device
3
Locaon and number of smoke alarms may be specified in relevant regulaons. Where these do not exist, the requirements of DIN 14676 can be used.
Before commencing installaon, ensure all equipment and tools to mount and test the device are available, such as drills, mounng screws (supplied), cables
and ladders.
Smoke alarm are to be used as minimum requirement in all bedrooms, children's rooms and hallways which act as escape routes, and are to be installed
in each case in the middle of the room, on the ceiling only (do not install on wall).
Select the installaon locaon with a minimum distance of 50 cm to surrounding walls, furniture and lamps.
According to German applicaon standard DIN 14676
Locaon Selecon
Equipment
Installaon
2
1
Configuraon is opmal when devices are also located in all other rooms as well as staircases.
In kitchens and wet rooms, smoke alarms are only used when false alarm caused by the characteriscs of these space are excluded.
Please observe the graphics in this guide.
Install smoke alarms as close to the centre of the ceiling as possible, away from light fings and air-condioning ducts. If this is not praccal, put the alarm on the
ceiling, no closer than 50 cm from any wall or corner.
In rooms with ceiling slopes> 20 °, the smoke alarm shall be mounted at least 0.5 m and not more than 1 m away from the ceiling peak.
Ceilings with a slope angle ≤ 20 ° should be treated as horizontal ceiling.
Installaon Locaon
Rooms with sloped ceiling
4
BEDROOM
CHILDREN’S
BEDROOM
CHILDREN’S
BEDROOM
LIVING ROOM
BATH-
ROOM KITCHEN
CHILDREN’S
BEDROOM
KITCHEN
WORKSHO
P
BOILER ROOM
LIVING ROOM
BEDROOM
Figure 1 b) Example of the applicaon in a typical single-family house
Figure 1 a) Example of the applicaon in a flat
Hold the coding buon and power the detector on at the same me. The detector will be formaed aer 8 s.
Format


Produktspezifikationen

Marke: Hikvision
Kategorie: Alarmanlage
Modell: DS-PDSMK-S-WB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hikvision DS-PDSMK-S-WB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Alarmanlage Hikvision

Bedienungsanleitung Alarmanlage

Neueste Bedienungsanleitung für -Kategorien-