Heatit Z-Smoke Bedienungsanleitung
Heatit
Rauchmelder
Z-Smoke
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Heatit Z-Smoke (6 Seiten) in der Kategorie Rauchmelder. Dieser Bedienungsanleitung war fĆ¼r 24 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/6
1. INTRODUCTION
Heatit Z-Smoke Detector is a multifunctional smoke sensor with a
built-in PIR motion sensor, temperature sensor and emergency light.
Heatit Z-Smoke Detector is a wireless operated photoelectronic smoke
detector designed to interact with most Z-Wave enabled controllers.
The detector features smoke-, temperature-, and IR-detection.
2. STATEMENT REGARDING PRODUCTS FROM MULTIPLE
MANUFACTURERS
Please read this before installation
This device may be used with all devices certiļ¬ed with the Z-Wave
Plusā¢ certiļ¬cate and should be compatible with such devices
produced by any manufacturer. Every primary controller is diļ¬erent
depending on the manufacturer, their target audience and intended
use/application. Please review the functionalities implemented by the
primary controller you intend to use with our Z-Wave Plus certiļ¬ed
device to ensure that it provides the necessary controls to take full
advantage of our productās capabilities.
3. BEHAVIOR WITHIN THE Z-WAVEā¢ NETWORK
This device may be operated within any Z-Wave network with
Z-Wave-certiļ¬ed devices from other manufacturers. All non-battery-
operated nodes within the network will act as repeaters regardless of
manufacturer to increase the reliability of the network. On delivery, the
device does not belong to any Z-Wave network.
The device needs to be added to an existing network to communicate
with the other devices within it. Devices may also be removed from
a network. The add/remove processes are initiated by the primary
controller of the Z-Wave network.
4. QUICK START
1. Unscrew the battery cover.
2. Insert three 3V CR123 Lithium batteries into the battery
compartment.
3. Orient the batteries according to the polarity.
4. The device will enter auto inclusion mode after being powered on.
5. Set the primary controller in add mode (security/non-security).
6. The Heatit Z-Smoke Detector is now included in your Z-Wave
network.
5. INSTALLATION/MOUNTING
1. Place the smoke detector at the desired mounting location
and use the Range Test function to make sure the smoke
detector can be detected by the control panel where it has been
placed.
2. A mounting sheet is included in the package. The illustration size
equals the smoke detectorās actual size and the perforated design
allows for easy removal after installation.
3. Position the sheet tightly against the ceiling and use the four holes as
a template to drill holes and insert wall plugs in the wall/ceiling if so
required.
4. Place the mounting bracket on top of the mounting sheet and screw
it onto the wall/ceiling.
TABLE OF CONTENTS
1 Introduction
2 Statement regarding products from multiple manufacturers
3 Behavior within the Z-Waveā¢ network
4 Quick Start
5 Installation/Mounting
6 Add/Remove
7 LED-indicator /Function button
8 Factory Reset
9 Testing the smoke detector
10 Alarm silence
11 Calibration
12 Serial connection
13 Security
14 Node Information Frame
15 Command Classes
15.1 Command Class Notiļ¬cation V8
15.2 Command Basic
15.3 Command Class Sensor Multilevel V11
15.4 Command Class Battery V1
16 Associations
17 Association Groups
18 Product information
HEATIT
Z-SMOKE
DETECTOR Ver 2020-A
Firmware 4.02
01.10.2020
Installers manual
BATTERY
BATTERY
5. The smoke detector has four notches on its back cover. Gently align
the four notches on the smoke detector with the hooks on the
mounting bracket. Rotate clockwise to lock the hook.
6. Installation is now complete. You may now tear oļ¬ the mounting
sheet.
a. LED-indicator/function button/emergency light.
b. IR-lens.
c. Buzzer.
d. Battery compartment ļ¬xing screw.
e. Battery compartment.
f. Hooks.
g. Mounting bracket.
h. Mounting holes (for the hooks on the mounting bracket).
i. Mount by aligning notches and hooks, then rotate clockwise.
Installation recommendations
ā¢ It is recommended to install the device in
the center of the ceiling.
ā¢ The device should be placed openly,
unobstructed by appliances and furniture.
ā¢ It is recommended to place a smoke
detector at the top of a stairway to detect heat and smoke rising
from below.
ā¢ For the device to function correctly, it is important to ensure that
its readings are done accurately in a stable environment. In order to
achieve this:
ā¢ Do not place the detector in the kitchen: Cooking fumes may
trigger the alarm.
ā¢ Do not place the detector near a ventilation fan, ļ¬uorescent lamp
or air-conditioning unit: Air drafts may aļ¬ect the accuracy of the
detector.
ā¢ Do not place the detector near ceiling beams, at the top point of
an āAā frame type ceiling or over a cabinet: Stagnant air in these
areas may aļ¬ect the accuracy of the detector.
ā¢ Do not place the detector where it may be exposed to direct
sunlight.
ā¢ Avoid installing the smoke detector in areas where other
installations may cause rapid changes in temperature within
the detection area, e.g. near air conditioners, heaters, boilers or
radiators.
ā¢ Avoid large obstacles in the detection area.
ā¢ Moving objects within the PIR detection area (e.g. curtains moving
in a draft) may cause an unwanted alarm. Avoid if possible.
The sensor will give false alarms when used in dusty areas like
washroom with tumbledryer. To test the PIR motion sensor: Press the
function button to enter test mode. Walk around the protected area,
and notice when the LED lights up. Check that the detection coverage
is adequate.
The smoke detector is designed to be mounted on the ceiling. The
ideal mounting height for the smoke detector is 2.7 to 3 meters above
ground. Mounting the detector higher than 3 meters above ground
may aļ¬ect detection performance.
The smoke detector can support detection coverage within a
diameter of 5 meters. Please refer to the illustrations below for
installation details.
6. ADD/REMOVE
Please read this before installation
The primary controller/gateway has a mode for adding or removing
devices. Please refer to your primary controller manual on how to set
the primary controller in add/remove mode. The device may only be
added or removed from the network if the primary controller/gateway
is in add/remove mode.
After power is applied, the smoke detector initiates a 1-minute warm-
up period. During this minute, the device will automatically enter add/
remove mode, and may now be added to the system via the primary
controller.
After the calibration process is ļ¬nished, you may access the add/
remove mode by pressing the function button three times within 1.5
seconds. Removing the device will reset it to factory settings.
If the device already belongs to a network, you must remove it from
that network before adding into a new one, or the setup will fail.
When the device is removed from the network, it will revert to factory
settings.
7. LED-INDICATOR /FUNCTION BUTTON
Red LED
ā¢ Turns ON brieļ¬y: Transmitting signal.
ā¢ Quick ļ¬ash: Alarm.
ā¢ Flashes every second: Smoke detector in sleep mode.
ā¢ Flashes every 2 seconds: Smoke detector in warm-up and calibration
process.
ā¢ Flashes every 4 seconds: Battery exhausted.
a
b
c
d
e
LOC K
g
h
i
f
3m
|
2,7m
IR Detection Coverage
At least 60 cm from
the wall
ļ¬ash. The smoke detector will emit 2 short beeps, then follow the
calibration process described in step 4 of the installation procedure
to set the new preferred value.
ā¢ Every time the battery is removed and re-inserted, the smoke
detecter will also set the new threshold value following the
calibration process
ā¢ After the initial installation, the smoke detector will perform
auto-calibration after 4 hours. Afterwards, it will perform an auto-
calibration once every month.
ā¢ If the calibration fails, the smoke detector will emit continuous
beeps, and the red LED will also ļ¬ash continuously. In this case, you
need to remove the batteries, wait for 30 seconds then re-insert the
batteries to restart the smoke detector.
12. SERIAL CONNECTION
The smoke detector may be used with other Heatit Z-Smoke
Detectors 230VAC (maximum 6 in same serial connection). The Heatit
Z-Smoke Detector Battery may be associated with the Heatit Z-Smoke
Detector 230VAC AC, which is a listening node. To beneļ¬t from this
functionality, it is necessary to assign associations to the other Heatit
Z-Smoke Detectors 230VAC AC. Heatit Z-Smoke Detector Battery may
only be associated with Heatit Z-Smoke 230VAC AC (listening nodes).
NB! Serial connection between Heatit Z-Smoke Detector Battery
and other Heatit Z-Smoke Detector Battery is not possible.
1. Add all smoke detectors to the same network.
2. Assign the smoke detectors to the correct zone/room in the primary
controller.
3. Access associations from the primary gateway (please refer to
primary controller manual).
4. Assign assocations from each device using association group 2
(Sensor Basic Set) to all other smoke detectors.
This way it is ensured that no matter where the ļ¬re is detected, the
devices will alarm with siren and emergency lights.
To stop an ongoing alarm, you can press the function button on
a smoke detector. If the smoke detector was triggered by another
device, the device will stop all alarms except from where the alarm
was triggered.
13. SECURITY
The S2 security enhances Z-Wave Plus with an additional layer of AES
128-bit encryption of the wireless Z-Wave communication to prevent
hacking and man-in-middle attacks on the home network.
Orange LED
ā¢ Flashes every second: Device power-on/calibration failed.
ā¢ Flashes every 5 seconds: Detecting smoke failed or device malfunctioning.
ā¢ Flashes every 4 seconds: Battery exhausted.
ā¢ Flashes every 45 seconds: Low battery condition
Function button
ā¢ Press the button once to send a test signal and temperature report to
gateway.
ā¢ Press the button once during an alarm to silence the alarm.
ā¢ Press the button 3 times within 1.5 seconds to learn mode.
ā¢ Press and hold the button for 10 seconds to enter the calibration process.
ā¢ Press and hold the button for 20 seconds to perform a factory reset.
White LED (emergency light)
ā¢ The emergency light will begin to ļ¬ash slowly to alert users that an
alarm has been triggered.
8. FACTORY RESET
Press and hold the function button for 20 seconds. This will reset the
smoke detector. It will also perform the calibration process.
NB! Please use this procedure only when the primary controller/
gateway is missing or otherwise inoperable.
9. TESTING THE SMOKE DETECTOR
By pressing the function button on the smoke detector, you can test if
the smoke detector is functioning normally.
ā¢ If the smoke detector functions normally, the Red LED turns on for 2
seconds, followed by a 2-tone beep.
ā¢ If the buzzer sounds 2-tone beeps 3 times, the āOptical Chamberā on
the smoke detector is either dirty or out-of-order.
ā¢ If the buzzer sounds 2-tone beeps 5 times, the āHeat Sensorā is out of
order.
10. ALARM SILENCE
When the smoke detector sounds the alarm, pressing the function
button sets the smoke detector to alarm silence mode to silence the
alarm for 9 minutes. The buzzer will only stop sounding after the alarm
has been activated for at least 1 minute.
If the smoke concentration has dropped below the alarm threshold
after the 9-minute alarm silence period has expired, the smoke
detector will emit a 2-tone beep and return to normal operation mode
without sounding the alarm.
If smoke concentration still exceeds the alarm threshold, the smoke
detector will start alarming again.
If smoke concentration continues to rise during the alarm silence
period and exceeds the second alarm threshold, the smoke detector
will start sounding again. An alarm activated by exceeding the second
alarm threshold could not be silenced by pressing the function button.
11. CALIBRATION
As the operating conditions of the smoke detector may vary after
having been installed for some time, you may wish to recalibrate the
smoke detector to set a new smoke detection threshold value and
ensure optimal performance of the smoke detector.
To do this:
ā¢ Hold the function button for 10 seconds until the red LED starts to
BATTERY AC
AC
AC
ACAC
Heatit Z-Smoke Detector combination
Heatit Z-Smoke Detector Battery and Heatit Z-Smoke 230VAC.
Use Asscociation group 2.
Produktspezifikationen
Marke: | Heatit |
Kategorie: | Rauchmelder |
Modell: | Z-Smoke |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Heatit Z-Smoke benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Rauchmelder Heatit
5 September 2024
Bedienungsanleitung Rauchmelder
- Rauchmelder Hama
- Rauchmelder Nedis
- Rauchmelder Trust
- Rauchmelder Brennenstuhl
- Rauchmelder Clas Ohlson
- Rauchmelder Cotech
- Rauchmelder REV
- Rauchmelder Bosch
- Rauchmelder Siemens
- Rauchmelder Eminent
- Rauchmelder IKEA
- Rauchmelder Schwaiger
- Rauchmelder Alecto
- Rauchmelder Denver
- Rauchmelder EMOS
- Rauchmelder Gira
- Rauchmelder Kƶnig
- Rauchmelder MarQuant
- Rauchmelder TFA
- Rauchmelder Blaupunkt
- Rauchmelder Grundig
- Rauchmelder Pyle
- Rauchmelder Vivanco
- Rauchmelder Abus
- Rauchmelder Elro
- Rauchmelder Olympia
- Rauchmelder Smartwares
- Rauchmelder Yale
- Rauchmelder Ferguson
- Rauchmelder Gigaset
- Rauchmelder Nexa
- Rauchmelder GEV
- Rauchmelder Gloria
- Rauchmelder Marmitek
- Rauchmelder Honeywell
- Rauchmelder B/R/K
- Rauchmelder First Alert
- Rauchmelder Flamingo
- Rauchmelder Netatmo
- Rauchmelder Hager
- Rauchmelder Bavaria
- Rauchmelder JUNG
- Rauchmelder Nest
- Rauchmelder Ei Electronics
- Rauchmelder FireAngel
- Rauchmelder Kidde
- Rauchmelder No-Flame
- Rauchmelder Kogan
- Rauchmelder M-e
- Rauchmelder Stabo
- Rauchmelder HQ
- Rauchmelder Busch-Jaeger
- Rauchmelder Swann
- Rauchmelder Sygonix
- Rauchmelder Chuango
- Rauchmelder EQ-3
- Rauchmelder FlammEx
- Rauchmelder Insafe
- Rauchmelder Pyrexx
- Rauchmelder EVE
- Rauchmelder Homematic IP
- Rauchmelder EQ3
- Rauchmelder Electia
- Rauchmelder Somfy
- Rauchmelder Elgato
- Rauchmelder ESYLUX
- Rauchmelder Fito
- Rauchmelder Fito Profi-line
- Rauchmelder Indexa
- Rauchmelder Interlogix
- Rauchmelder KlikaanKlikuit
- Rauchmelder Mercury
- Rauchmelder Satel
- Rauchmelder Steren
- Rauchmelder X-Sense
- Rauchmelder Dahua Technology
- Rauchmelder Inovonics
- Rauchmelder Pentatech
- Rauchmelder H-Tronic
- Rauchmelder FireX
- Rauchmelder Lupus Electronics
- Rauchmelder System Sensor
- Rauchmelder Malmbergs
- Rauchmelder Chacon
- Rauchmelder Fibaro
- Rauchmelder ORNO
- Rauchmelder WisuAlarm
- Rauchmelder Cavius
- Rauchmelder DSC
- Rauchmelder Cordes
- Rauchmelder STI
- Rauchmelder Deltronic
- Rauchmelder Minute Man
- Rauchmelder Gewiss
- Rauchmelder Calex
- Rauchmelder Mobeye
- Rauchmelder Qolsys
- Rauchmelder Ajax
- Rauchmelder AngelEye
- Rauchmelder FirstAlert
- Rauchmelder FireHawk
- Rauchmelder ETiger
- Rauchmelder TEF
- Rauchmelder Jalo Helsinki
- Rauchmelder Pristine
- Rauchmelder Jemay
- Rauchmelder Mircom
- Rauchmelder BRK DICON
- Rauchmelder Egardia
- Rauchmelder Frient
- Rauchmelder SAVS
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
16 Oktober 2024
16 Oktober 2024
14 Oktober 2024
14 Oktober 2024
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
8 Oktober 2024
7 Oktober 2024
4 Oktober 2024