Safety instructions
Electrical equipment must only be installed and assembled by a qualied
electrician in accordance with the relevant installation standards, regulations,
directives and safety and accident prevention directives of the country.
Failure to comply with these installation instructions may result in damage to
the device, re or other hazards.
Function
The DND&MUR switch has been developed for electrical installations in hotel
buildings. A status “Do Not Disturb “Make Up Room” or can be activated by the
hotel guest with the DND&MUR switch in the hotel room. The status message can
be signalled by a corresponding indicator (not included) outside room on the hotel
corridor.
Correct use
- For the flush-mounted installation in standard wall boxes (depth of box ≥ 35 mm).
- Only suitable for use in indoor areas with no drip and no spray water.
Technical data
Switch rating: 250 V~, 16 AX
Conductor cross-section of screw terminals: min. 1 x 1.5 mm² ² ... max. 2 x 4 mm
Distance of fixing holes: 60.3 mm
Switch compliance: BS EN 60669-1, IEC 60669-1
16AX DND&MUR switch w/LED
Hager Muse / Hager Inspire
Installation and operating
instructions
2
Operating the device
Inside hotel room:
DND&MUR switch
On the hotel corridor
in front of hotel room
"Do Not
Disturb"
- DND contact is
closed.
- DND-LED lights up
in red colour.
- MUR contact is
open.
- Optional bell switch
terminal is cut off.
- "Do Not Disturb" status
can be signalled by a
corresponding indicator.
- No bell-ringing possible.
"Make Up
Room"
- MUR contact is
closed.
- MUR-LED lights up
in green colour.
- DND contact is open.
- Optional bell switch
terminal is supplied.
- "Make Up Room" status
can be signalled by a
corresponding indicator.
(If both
rockers
are
pressed)
- DND status has
priority.
- DND contact is
closed.
- DND-LED lights up
in red colour.
- MUR contact is
open.
- Optional bell switch
terminal is cut off.
- "Do Not Disturb" status
can be signalled by a
corresponding indicator.
- No bell-ringing possible.
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts can result in an electric shock.
An electric shock can lead to death.
Disconnect the connecting cables before working on the device and
cover all live parts in the area!
ç
3
Preparing the device for installation
Rockers
Frame
Notches
1
Carefully loosen frame on the notches with a at-blade screwdriver. Lift up and
remove the frame ( ).1
Remove both rockers also with a at-blade screwdriver.
Connecting the device
Figure 2 shows the wiring of the DND&MUR switch as well as the connection to a
corresponding indicator, a bell switch and a 230V buzzer.
L
N
L2
L1 L1
COM
COM N
DND&MUR switch w/LED
230V buzzer
MUR
DND
Inside hotel room2 On the hotel corridor
Bell
switch
Strip connection cables approx. 10 mm.
Wire the device according to the connection diagram ( ).2


Produktspezifikationen

Marke: Hager
Kategorie: Nicht kategorisiert
Modell: WGCXHDCNB

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager WGCXHDCNB benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Hager

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-