Hager TRE521 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hager TRE521 (6 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
TRE50., TRE52.
zMotion Detectors 220°
User instructions
¨
220° DETECTORS
TRE500 White
TRE501 Anthracite
TRE520 White
TRE521 Anthracite
ACCESSORY FOR
ANGLE FIXING
EE855 White
EE856 Anthracite
52125 White
52126 Anthracite
α
IP55
+ 90°/- 30°
+/-80°
Description
Detection zone
Installation
Wall fixing plate Adjustment potentiometers
Directional detection head
Adjustments
Shutters
Angle fixing support
Vertical adjustment
Optimal installation height is 2.5m.
The detection zone shall remain free of obstacle.
m 8 m 16
m 2,5
m 0,5
m 16
m 4
LED LED A B
Delay
(lighting time)
Brightness
level
Sensitivity
(change
of range)
1
2
6LE003097B
V2.6.0
RFTP 230V~ Bus
30 V
16LE003097B
Warning :
This device is to be installed only by a
professional electrician fitter according to
local applicable installation standards.
Test and validation of detection
zone
Set potentiometer 2 to Test mode.
The Test mode is available for 3 minutes time
and does not take brightness level into
account.
Each detected movement turns LED on for 2 A
seconds.
The associated receiver is controlled.
After 3 minutes without detection, the product
is set back to auto mode.
Limitation of detection zone :
You can limit the detection zone using the
shutters supplied or by inclining the head.
Mounting
Projection or ceiling mount :
- Fix the wall plate using the supplied screws.
- Clip the detector onto the wall plate
- Tighten the screws to close.
For angle mounting, the wall fixing plate is
fitted between the accessory and
the detector.
Precautions for installation
For optimum detection conditions, please fol-
low these recommendations :
- Keep the detector protected from solar radia-
tion and bad weather, as it is sensitive to
these conditions.
- Maintain 1m distance between the light
source and the detector and keep the detec-
tor out of the light source.
Product Description and working
principles
This detector allows remote control of one
or more receivers for a given time when a
movement is detected in its detection zone.
This product can be used in two types of
configuration: one detector controls one/seve-
ral receiver(s); several transmitters control the
receiver(s).
Operation
The receiver(s) is(are) under control as soon as
the brightness level as set by potentiometer
2 is considered too low and a movement is
detected.
Upon detection, the time delay is restarted.
If LED ashes quickly during configuration, A
the position of potentiometer 1 is not compa-
tible with the selected function.
If LED flashes quickly or nothing occurs B
when starting configuration, check that the
batteries are correctly installed and replace
them if necessary. Product factory reset is
recommended before any new configuration.
Factory return
Keep push-button depressed until LED J
cfg ( . flashes (>10s), and then release it
LED cfg is turned o when factory return is
completed.
This operation causes full delete of product
configuration in any configuration mode.
After factory return, wait 15s before starting.
Action Adjustments Potentiometer
Use Auto (factory)
settings to set
automatic lighting
turn-on for
a given time.
Only available when
a detector’s time
delay is set.
Auto Settings
Put the Lux potentiometer on
“ ”.auto test
The settings are predefined :
Lux = ,
(operating at night only)
time = 3 min,
sensitivity = max
Turn automatic
lighting on for
a given time.
Only available when
a detector’s time
delay is set.
Installer settings
Test and confirm
detection zone.
Test mode
Move the potentiometer 2
to auto test.
Adjust sensitivity. Allows setting the range
to avoid disturbance.
Installing batteries J Button
cfg
cfg
LED C
Button J
Configuration (button J )
These detectors can be configured in 3 dierent
ways :
quicklink
: tool-free configuration (using product
pushbuttons and LEDs), see User's Instructions
6T7952 supplied with the product.
TX100/B V2.5.0 or above :
description of product functions available from
the Manufacturer.
ETS3 or via TR131 : database and description of
application software available from the
Manufacturer.
Configuration by TX100 or ETS
Set the product in configuration mode by pressing
J button once during the teaching session of
TX100 or for addressing with TR131 in ETS.
OProduct factory return is required to change
the configuration mode.
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment).
(Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it hould not be disposed with other
household wasted at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle
it responsibly to promote the sustainable reuse of
material resources.
Household users should contact either the retailer
where they purchased this product, or their local
government oce, for details of where and how they
can take this item for environmentally safe recycling.
Business users should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with other
commercial wastes of disposal.
Usable throughout Europe å and in Switzerland
Hager Controls hereby declares that the TRE50., TRE52.
device complies with the essential requirements and other
relevant provisions of Directive 2014/53/EU.
The CE declaration is available on the:
www.hagergroup.com
26LE003097B
Kit Description TRE700 / 720
The detector and the receiver must be preset in
order to operate together.
These two products are pre-configured to operate
together. Only delay, brightness level and
detection zones are to be set by user.
Setting detector’s delay Setting receiver’s delay
Kit TRE700 Pre-configured
(ON/OFF switch function)
1. Clear the previous pre-configured function
if Kit TRE700 is used (See the Configuration
Instructions)
2. Set the potentiometer to position
3. Configure the "timer"
(See the Configuration Instructions)
1 detector TRE5..
+
1 receiver
Recommended configuration :
1. Set the potentiometer to a value dierent
from
2. Configure ON/OFF switch function (See the
Configuration Instructions)
Kit TRE700
+
1 or several
other receivers
In order to have the same delay on each recei-
ver :
1. Set the potentiometer to a value dierent
from
2. Configure the ON/OFF function (See the switch
Configuration Instructions) on other receivers
In order to have a dierent delay on each recei-
ver :
1. Clear the previous pre-configured function if
Kit TRE700 is used (See the Configuration
Instructions)
2. Set the potentiometer to position
3. Configure the "timer" function
(See the Configuration Instructions)
1 detector TRE5..
+
several receivers
1. Set the potentiometer to a value dierent
from
2. Configure the ON/OFF switch function (See the
Configuration Instructions) on each receiver
Several detectors
TRE700-TRE5…
+
1 or several
receivers
Not recommended (conflict of delays) 1. Clear the previous pre-configured function if
Kit TRE700 is used (See the Configuration
Instructions)
2. Set the potentiometer to position on both
detectors.
3. Configure the "timer" function
(See the Configuration Instructions)
on each receiver
Kit TRE700/720
or
1 detector TRE5..
+
1 or several
transmitters
other than detectors
+
1 or several
receivers
Timer function being not used on the other
transmitter(s) :
1. Set the potentiometer to a value dierent
from
2. Configure the other transmitter(s)
(See the Configuration Instructions)
with a function other than timer
Timer function used on the other transmitters :
1. Clear the previous pre-configured function if
Kit TRE700 is used (See the Configuration
Instructions)
2. Set the potentiometer to position
3. Configure the "timer" function
(See the Configuration Instructions) on each
receiver for each transmitter involved
TROUBLESHOOTING...
Problem auses olutionsC s
Unwanted lamp
switch on.
- Permanent heat source is active in the detection area (trees, bushes
shook by wind or presence of dogs, cats in the detection area).
- The detector is located on top a ventilation grill.
- Limit detector’s range by adjusting its inclination or by fitting shut-
tering blades to the lens, or by lowering sensitivity using the
adjustment knob.
- Move the detector to another location.
The range of
the detector is
too narrow.
- Detector’s installation height is not suitable (too high or too low).
- Sloppy ground.
- Modify installation height (2.5m is optimal).
- Adjust detector’s direction.
Moving vehicle or
person is not
detected.
- Vehicle’s motor is not enough yet (heat radiation is too weak).
- People move forwards in front of detector.
- Detector energy too low.
- Install the detector in such a way that objects move within the area
in transverse direction.
- Replace power cells.
- Place detector in a suitable location with solar cell directed towar-
ds the sun.
Technical specifications
Electrical specifications
Power Supply :
- TRE50., TRE52. 3 x 1,5V AAA
Operational characteristics
Dimensions (L x w x h) : 153 x 91 x 130 mm
Luminosity threshold : 5 —> 1000 Lux
Fixed time : 30 s —> 15 min
Sensitivity : min. 20%, max. 100%
Limiting the detection zone : Adjustable shutters supplied
Transmission frequency : 868-868.6 MHz
Receiver category : 2
Maximum emission power: 25mW
RF KNX Communication Media RF knx : RF1.R
Configuration mode RF KNX : Quicklink, Easy link
Controller, ETS via media coupler
Range : 100 m on open field
(Please refer to Detector User's Instructions).
Other devices can be added to the kit.
Various configuration options are available
When a detector is associated with a receiver, only 2
functions are available, depending on potentiometer’s
position :
- (Red/Green LED) or timer (Red flashing LED)
according to the case
- Delete (LED is OFF)
The receiver will oer only the function set by the
potentiometer.
Note : During configuration of a detector, Step 2 of the Configuration Instructions shall be ignored.
Fixing accessories : corner support
(sold separately) EE855/52125, EE856/52126
Environment
Operating temperature : -20 °C —> +55 °C
Storage temperature : -20 °C —> +60 °C
IK : 04
Protection class : IP55
Resistance to fire : 750°C
When a product is factory reset,
pre-configuration is removed.
It should then be configured again.
36LE003097B


Produktspezifikationen

Marke: Hager
Kategorie: Nicht kategorisiert
Modell: TRE521

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager TRE521 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Hager

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-