Hager SPN215R Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hager SPN215R (5 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
4.55
Sales Service Centre • 01952 675612 Technical Support Helpline • 01952 675689
Type 1 + Type 2 / Class I Surge Protection Devices
SPN8***
SPN801 / SPN801R SPN802 / SPN802R
Tested to EN 61643-11
(VDE0675-6-11) 2002-12
EN 61643-11
(VDE0675-6-11) 2002-12
L1/L2/L3/N => PE L1/L2/L3 => N N => PE
SPD type / class Type 1 + Type 2 / I / B
Type of connexion Parallel connection
Type of power supply system TN-S - System TT - System
Type of protection Common modes Common and differential modes
Nominal voltage UN230V / 400V ac
Rated voltage Uc255V ac
Voltage protection level Up≤ 1.5kV 255V ac
TOV-voltage UT440V / 5s 1200V / 200ms
Rated load current I(L) 315A
I(L-L) 125A
Follow current interrupting rating I
50 kA 100kA
Nominal discharge current (8/20) I
n100kA 25kA 100kA
Impulse current (10/350) I
imp 100kA 25kA 100kA
Residual current IPE ≤ 100mA
Max. rating of overcurrent
protection
fuse 125A gL / gG serial or 315A parallel
MCCB 125A serial or 160A parallel
Short-circuit withstand capability
with max. overcurrent protection
fuse 50kA ac 25kA ac
MCCB 50kA ac 25kA ac
Response time tA< 100ns
Operating temperature range - 40°C ….+ 60°C
Indication of SPD disconnector Green - red on L1, L2, L3, N
Cross sectional area min 10mm
2 solid / exible
L1, L2, L3, PE max 50mm
2 multi-stranded / 35mm
2 exible
Tightening torque for terminals 7.0 Nm
Mounting on 35mm DIN rail in accordance with EN 60715
Enclosure material grey thermoplastic, UL 94V-0
Degree of protection IP20
Modular width 6 8
Weight 1260 g 1272 g
Approval marking VDE
Protection
Devices
4.56 General Catalogue • Protection Devices • Technical
Type 1 & 2 Surge Protection Devices
SPA215*, SPA400*, SPA401*
SPA201 SPA401
Tested to EN 61643-11 2002-12
SPD type / class Type 1 + Type 2 / Class I
Energy-coordinated
protection effect on terminal
equipment
Type 1 + Type 2
Energy-coordinated
protection effect on
terminalequipment 5 m≤
Type 1 + Type 2 + Type 3
Type of connexion Parallel connection
Type of power supply
system
TT / TN system
Type of protection common and differential modes
Nominal voltage UN230V/400V ac
Rated voltage Uc255V ac
Voltage protection level Up≤ 1.5kV
TOV Voltage UT440V / 5s
1200V / 200ms
Rated load current I(L) n/a
I(L-L) n/a
Follow current interrupting
rating
I25kA rms
100A rms
Nominal discharge current
(8/20)
In12.5kA
25kA
12.5kA
50kA
Impulse current (10/350) Iimp 12.5kA
25kA
12.5kA
50kA
Max. rating of overcurrent
protection
fuse 160A gL / gG
MCCB n/a 160A
Short-circuit withstand
capability with max.
overcurrent protection
fuse 25kA rms
MCB n/a
Response time tA≤ 100ns
Operating temperature
range
- 40°C ….+ 80°C
Indication of SPD
disconnector
Green/Red ag on L and N Green/Red ag on L1, L2, L3 and N 
Cross sectional area min 1,5mm2 solid / exible
max 35mm2 stranded / 25mm2 exible
Tightening torque for
terminals
4 Nm
Mounting on 35mm DIN rail in accordance with EN 60715
Enclosure material grey thermoplastic, UL 94V-0
Degree of protection IP20
Modular width 2 4
Weight 275 g 480 g
Approval marking KEMA
4.57
Sales Service Centre • 01952 675612 Technical Support Helpline • 01952 675689
Type 2 / Class II Surge Protection Devices
SPN215*, SPN415* & SPN440*
SPN215D/R SPN415D/R SPN440D/R
Tested to EN 61643-11 (VDE0675-6-11) 2002-12
SPD type Type 2 according to EN 61643-11
SPD class Class II according to IEC 61643-1
Type of connexion Parallel connection
Maximum continuous operationg voltage U
cLine / Neutal 255V ≤
Neutral/ PE 275V ≤
Voltage protection level Up≤≤≤ 1kV 1kV 1.2kV
Nominal discharge current (8/20 µs)
[(DC+/DC-) --> PE]
In5kA 5kA 15kA
Max. discharge current (8/20 µs) [(DC+/DC-) -->
PE]
Imax 15kA 15kA 40kA
Short-circuit withstand capability with max.
overcurrent protection
10kA - 32A 10kA - 32A 20kA - 32A
Operating temperature range - 40°C ….+ 80°C
Indication of SPD disconnector Green - Yellow - Red
Cross sectional area min 1,5mm2 solid / exible
max 35mm2 multi-stranded / 25mm2 exible
Tightening torque for terminals 4.0 Nm
Mounting on 35mm DIN rail in accordance with EN 60715
Enclosure material grey thermoplastic, UL 94V-0
Degree of protection IP20
Modular width (DIN 43880) 2 2 4
Auiliary contact. Voltage/ nominal current
(only applicable on the R suf x products)
230V/ 0.5A
12Vdc
10mA
Protection
Devices


Produktspezifikationen

Marke: Hager
Kategorie: Nicht kategorisiert
Modell: SPN215R

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager SPN215R benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Hager

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-