Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 1
Invicta 3 TP&N Distribution Board
125A
Invicta 3 125A
TP&N Distribution Boards
A range of Type B TPN Distribution boards
with high aesthetics ideal for commercial
ofces, healthcare and education projects
where the boards may be sited in public areas.
Features & Benets
- High aesthetic glazed door option for siting in public areas
- Range of incomer options suitable for a wide range of building
applications
- Door locking kit with key for additional security
- Meter and surge protection options to meet application needs.
- Part of a wider range of Distribution boards
- Comprehensive solution for commercial building applications including
250A, Power & Lighting boards and Hybrid Distribution board
Description
Cat ref.
Plain door
Cat ref.
Glazed door
Cat ref.
Residential
Applications
4 Triple Pole Ways 125A TP&N Board JK104B ¹ JK104BG ¹ JK104BA3 ²
6 Triple Pole Ways 125A TP&N Board JK106B ¹ JK106BG ¹ JK106BA3 ²
8 Triple Pole Ways 125A TP&N Board JK108B ¹ JK108BG ¹ JK108BA3 ²
12 Triple Pole Ways 125A TP&N Board JK112B JK112BG JK112BA3 ²
16 Triple Pole Ways 125A TP&N Board JK116B JK116BG JK116BA3 ²
18 Triple Pole Ways 125A TP&N Board JK118B JK118BG JK118BA3 ²
24 Triple Pole Ways 125A TP&N Board JK124B JK124BG JK124BA3 ²
Incomer Kits for 125A Boards Cat Ref.
3 Pole 100A Switch Disconnector Incomer Kit (Fits within distribution board) JK11003S
4 Pole 100A Switch Disconnector Incomer Kit (Fits within distribution board) JK11004S
3 Pole 125A Switch Disconnector Incomer Kit (Fits within distribution board) JK11253S
4 Pole 125A Switch Disconnector Incomer Kit (Fits within distribution board) JK11254S
4 Pole 63A Contactor Incomer Kit includes Switch Disconnector (ts below distribution board, 300mm high) JK10634C
4 Pole 100A Contactor Incomer Kit includes Switch Disconnector (ts below distribution board, 450mm high) JK11004C
125A Direct Connection Kit (Fits within distribution board) JK11254D
4 Pole 63A 30mA RCCB Incomer Kit (Fits within distribution board) JK10634RH
4 Pole 100A 30mA RCCB Incomer Kit (Fits within distribution board) JK11004RH
4 Pole 100A 300mA RCCB Incomer Kit (Fits within distribution board) JK11004RL
4 Pole 100A 300mA Time Delayed RCCB Incomer Kit (Fits within distribution board) JK11004RLD
4 Pole 100A 100mA RCCB Incomer Kit (Fits within distribution board) JK11004RM
4 Pole 100A 100mA Time Delayed RCCB Incomer Kit (Fits within distribution board) JK11004RMD
125A 4 pole Changeover Incomer Kit (Fits within distribution board) JK11254CO
Conforming the BS EN 61439-3, the Invicta boards are available with
glazed or solid steel doors to suit installation requirements. A wide range
of incoming options create a versatile solution. Metering and surge
protection options ensure efcient integration in to the buildings electrical
supply model. A 250A TP&N board range is also available for higher load
applications.
Hager Ltd. Hortonwood 50, Hortonwood, Telford, TF1 7FT / 01952 675 675 2
Invicta 3 TP&N Distribution Board
125A
Technical Characteristics
Standards Designed, manufactured and tested to
BS EN 61439-3
Busbar Current Rating 125A
Busbar Type Fully shrouded copper
Busbar Rating 25kA Conditional
Incoming 100A Switch
125A Switch
63A Contactor AC3
100A Contactor AC3
Direct Connection
RCCB Incomers
Outgoing Ways 4, 6, 8, 12, 16, 18, 24 Triple pole outgoing ways
Outgoing Protection Type B MCB (6A to 63A, 1P & 3P)
Type C, D MCB, (0.5A to 63A, 1P & 3P)
1Mod and 2Mod RCBO
Voltage Rating in AC 230 / 415V
IP Protection IP3X to BS EN 60529
Enclosure Body Type Steel
Enclosure Paint Type Powder Coat Grey White BS4800 00A01
Cable Entry Obround protected cable entry points
Terminal Connection Capacity
Incoming Line Terminal 50mm2
Incoming Earth Terminal M8 stud
Incoming Neutral Terminal 50mm² cage or M6 stud
Outgoing Earth Terminals 16mm²
Outgoing Neutral Terminals 16mm²
Enclosure Earth Stud M8
Installation
Mounting 4 x key hole xing holes plus central top key hole for one xing hanging /
levelling
Surface Wall Mount
Gland Plate Top and bottom removable
Integrated Locking System Coin lock as standard, key lock as
accessory
Devices
MCB 10kA 0.5A to 63A NBN*** NCN*** NDN***
RCBO 10kA 6A to 45A ADB*** ADC*** ADA1** ACB*** ACC***
MCB 10kA / 15kA 80A to 125A HMC*** HMD***
125A Primary Boards
Dimensions (mm) Fixing Centres (mm)
Height Width Depth A B C
JK104B/BG/A3 500 465 132.5 365 100 300
JK106B/BG/A3 550 465 132.5 365 100 350
JK108B/BG/A3 625 465 132.5 365 100 425
JK112B/BG/A3 850 465 132.5 365 100 650
JK116B/BG/A3 950 465 132.5 365 100 750
JK118B/BG/A3 1100 465 132.5 365 100 900
JK124B/BG/A3 1250 465 132.5 365 100 1050
L1 L2 L3
L1
L2
L3
L1
L2
L3
IS OL E SU PPAT LY
BEFORE REM OVI NG COVER
UN
LOCK UN
LOCK
L1 L2 L3
Depth
B
C
A
Height
Width


Produktspezifikationen

Marke: Hager
Kategorie: Nicht kategorisiert
Modell: JK108BA3

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager JK108BA3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Hager

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-