Safety switch (RCCB's) 25 - 100 A
|
6LE003036Ad - 145822
OFF
green
z
For the tripping times veriξΊcation tests, in an
electrical installation, Hager certiξΊes that the RCDs, of
the Hager brand, conforming to standards EN 61008-
2-1, EN 61009-2-1, trip under a current of 5*IΞn in
accordance with the times imposed in table 41.1 of
standard DIN VDE 0100-410 (VDE 0100-410) 2018-10.
Position contact indication.
Test
1, 3, 5...12
Fev.
Fev.
Fev.
Fev.
Fev.
Jan.
Jan.
Jan.
Jan.
Jan.
Test
OFF
yellow
or
Earth leakage fault indication.
Please note the following
1 - The current rating per pole of the RCCB must not be
exceeded by the maximum demand of the protected
circuits.
2 - If RCCB trips OFF after installation, locate and repair
faulty appliances (cumulative leakage from a number
of appliances may exceed the RCCB tripping
current, causing RCCB to trip OFF).
3 - The βmain neutralβ and βmain earthβ should be
checked to ensure good connection.
4 - If RCCB trips intermittently will not reset, or test
button will not work, check for low insulation
resistance between neutral & earth wiring.
5 - RCCB may be fed in any position:
LOAD and LINE circuits may be connected top or
bottom.
Electrical connection for P+N or for three phase only.
Three phase & neutral use
or Three phase use
Single phase use
Two circuits
L1
L1
T
2 4 6 8
1 3 5 7
N
N
N
N
ξ ξ ξ ξ 1
ξ ξ ξ ξ 1
/ 1 1/
/ 1 1/
7
7
/ξ
ξ ξ ξ ξ 1
ξ ξ ξ ξ 1
/ξ
/ξ
/ξ
/ξ
/ξ 1
1
One circuit
Electrical connection 2 pole.
For an RCD where two or three circuits are to be protected, the Hager neutral link KM03A
may be connected to the outgoing N terminal for the convenient splitting of the neutrals.
N1 N2 L2L1
2
1 3 N
L
KM03A
RCD
Neutral
Link
Main
Neutral Link
4 N
T
L1 circui- t
1
L2 circui- t
2
Safety instructions
The installation and mounting of electrical
appliances must only be performed by qualiξΊed
electricians, in compliance with installation
standards and in accordance with the guidelines,
provisions and safety and accident prevention
regulations in force in the country concerned.
14 mm max. 16 - 63 A 80 - 100
A
16
mm
2
35
mm
2
25
mm
2
50
mm
2
1Hager Electro S.A.S., Boulevard d'Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com
+
2 T +33 (0)3 88 49 50 50 info@hager.com hager.com β 10.2022
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
Γ 3,5/
6 max.
Auxiliary possibilities.
q
Possible use of
the RCD neutral
link KM03A
5
1
Single phase connection.
5
1
Three phase connection.
KDN180A
KDN180G
KDN380A
KDN380G
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
ξ
3,6 Nm3,6 Nm 3,6 Nm
MZ201
MZ202
MZ203
MZ204
MZ205
MZ206
A
A
B
B
C
C
Locking device for handle MZN175.
Protection against dust
In case of work activities nearby, make sure that the
electrical nstallation is protected against dust if the
enclosure is not IP5x.
Produktspezifikationen
Marke: | Hager |
Kategorie: | Stromkreisunterbrecher |
Modell: | CDA680T |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Hager CDA680T benΓΆtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Stromkreisunterbrecher Hager
27 Mai 2024
25 Mai 2024
23 Mai 2024
20 Mai 2024
20 Mai 2024
16 Mai 2024
15 Mai 2024
13 Mai 2024
1 Mai 2024
28 April 2024
Bedienungsanleitung Stromkreisunterbrecher
Neueste Bedienungsanleitung fΓΌr -Kategorien-
2 April 2024
28 MΓ€rz 2024
23 MΓ€rz 2024
1 MΓ€rz 2024
16 Januar 2024
5 Dezember 2023
2 Dezember 2023
27 August 2023
13 August 2023
3 Juli 2023