Hager 85345126 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hager 85345126 (3 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/3
KNX radio motion detector comfort
1.1 m quicklink
Order no. 8534 51 ..
KNX radio motion detector comfort
2.2 m quicklink
Order no. 8534 61 ..
Configuration instructions
Berker GmbH & Co. KG
Zum Gunterstal
66440 Blieskastel, Germany
Tel.: + 49 6842 945 0
Fax: + 49 6842 945 4625
e-mail: info@berker.de
www.berker.com
04/2022
6LE007947A
z
KNX radio con guration
quicklink
The radio confi guration sets up the functional
connection between commanding (transmitters)
and function-executing (receivers) radio compo-
nents. Thus, central, group, extension unit and
time controls, for example, can be implemented in
a wireless manner.
The following can be con gured:
-The local operation of the load connected to the
insert
- Radio commands to control other receivers
- Functions which are executed when the radio
commands are received
See Table 5
For confi guration by means of Hager connec-
tion device TX100 or ETS, additional functions
are available (see operating instructions for
TX100 or application description for ETS).
Confi guration to control the load connected to the
insert via reception of a radio command.
As an example, the confi guration of a wall-trans-
mitter and a radio motion detector as receiver is
described (Table 6).
fct LED
display
Confi gurable
functions
Function resulting from transmitter operation,
notes
On switch insert
On dimmer insert
ON/OFF 1)
ON/OFF,
dim UP/
DOWN
1)
Short button-press: Switch ON/OFF
Long button-press: Dimming, reverse dimming direc-
tion per actuation
ON
1)
ON,
dim UP
1)
Short button-press: Switch ON
Long button-press: Dim UP to maximum brightness
OFF
1)
OFF,
dim
DOWN
1)
Short button-press: Switch OFF
Long button-press: Dim DOWN to minimum bright-
ness
1
1)
Receiver is allocated to a scene due to the confi gura-
tion of the function.
Short button-press: Short button-press: Recall the
saved state of the connected load for the scene
2
1)
1)
Switch ON for the set switch-on time
Factory setting = 3 min
1)
Closing of the activating contact switches the load
ON, opening of the contact switches the load OFF.
Switches the load with higher priority to the appropri-
ate state. Execution of other commands is only possi-
ble after resetting the forced command.
simulation 1)
Activates/deactivates execution of presence simula-
tion (See Activating/deactivating presence simulation).
2)
Is used to extend the detection area. Receives
switch-on commands in case of motion detection in
the detection area of the transmitter (Slave). Switches
the lighting ON for the set delay time.
The brightness evaluation only takes place on the
master, the slave only detects motion.
Can only be confi gured between radio motion
detectors.
No function
Assignment to transmitter is deleted
1)
Execution of the receiver function and local motion detector function have the same priority:
If the transmitter was fi rst switched on/off and then motion was detected afterwards, then the motion detector will
override the transmitter command
If motion was detected and thereafter, during the delay time, the system is switched on/off via the transmitter, then
the transmitter will override the motion detector
2)
Only with KNX radio motion detector on power supply for KNX radio application module as transmitter
Table 5: Con gurable functions
Operation
Result
Start confi guration
Press the button on the wall-transmitter cfg
briefl y.
If there is no further activation, the
confi guration is automatically ended after 10
minutes.
The LEDs on the wall-transmitter and the radio cfg
motion detector light up in red colour.
T
150
90°
...
45° 4
...
90°
fct
cfg
All the receivers within radio range also display the
confi guration mode.
Select transmitter button
Briefl y press the press-activation point on the
wall-transmitter, which should activate the
function.
The cfg LED on the wall-transmitter fl ashes for 1
second.
If confi gured already fct LED of the motion detector
indicates the currently con gured function.
Select function on receiver
Repeatedly apply short presses to the fct
button on the motion detector until the desired
function is displayed (Table 5).
T
150
90° 45° 90° ...
fct
cfg
After each operation, the fct LED indicates the
function.
If the transmitter button has already been
confi gured with a function in a diff erent receiver
and/or the confi gured function is part of a group
control, only this function can be confi gured.
To change a function, the existing confi guration
must be deleted and the new one needs to be
confi gured.
Confi rm function on receiver
To confi rm, keep the button pressed for fct
more than 2 seconds.
T
150
90° 45° 90° ...
fct
cfg
> 2 s
The cfg LED fl ashes during the saving process
(approx. 5 s). The LED confi rms the function fct
selection by displaying the corresponding colour.
T
150
90° 45° 45° 90° ... ...
fct
cfg
Rapid ashing of the cfg LED indicates a
combination that is not possible or an error.
Completing the confi guration
Briefl y press the cfg button on the wall-
transmitter again.
The LEDs on the wall-transmitter, on the motion cfg
detector and on all receivers within radio range go
out. The function is confi gured.
Table 6: Con guration of the function for the KNX radio motion detector
Confi guration of KNX radio motion detector as a receiver
Confi guration of KNX radio motion detector as
a transmitter
If the radio motion detector is operated as a trans-
mitter, it can support the following functions for
receivers. The specifi c function can vary depend-
ing on the receivers used:
ON/OFF (delay time)
Preconfi gured command in Automatic
mode: Motion detection with simultaneous
undershooting of the brightness threshold
switches the load ON and, after the delay
time has elapsed, it switches the load
OFF. The delay time elapses in the motion
detector and is permanently set (3 min).
Timer
Motion detection with simultaneous
undershooting of the brightness threshold
switches the load ON and, after the switch-
on time has elapsed, it switches the load
OFF. The switch-on time elapses in the
receiver and can be adjusted through
confi guration.
The radio motion detector must be attached to
a switch insert or dimmer insert. If the radio
motion detector is mounted on a power supply
for KNX radio application modules, then it can
only be confi gured as a transmitting extension
unit (slave) (see Executing a master-slave con-
guration).
As an example, there is a description of confi gur-
ing the radio motion detector with receivers below,
for which the LED and cfg fct LED provide the
supported displays (Table 7). Diff erent confi gura-
tion displays, such as for receivers with a display,
are provided in the instructions for the receiver.
Executing the master-slave con guration
If the radio motion detector is attached to a power
supply for radio application modules, then it can
only be confi gured as a transmitting extension
unit (slave) to a radio motion detector on switch or
dimmer insert (Table 8).
The slave motion detector sends a pulse in case
of motion detection in its detection area. Upon
receiving this pulse, the master switches on for
the delay time, if the set brightness threshold is
undershot. Delay time and brightness threshold
are determined by the master.
Deleting a confi guration
To delete a con gured receiver or the local opera-
tion, perform the confi guration again.
Start confi guration (see Con guration of radio
motion detector as a receiver).
If necessary, select transmitter button.
The select transmitter button step does not ap-
ply for radio motion detectors as transmitters.
Select function on receiver: Select the Delete
function on the receiver and confi rm the func-
tion on the receiver.
Completing the confi guration: Brie y press the
cfg button on the transmitter.
Confi guration of group functions
By means of a group function, one transmitter, for
example,
a radio motion detector, controls several receivers.
To do so, the same functions must be confi gured
on all receivers.
Start confi guration (see Con guring radio mo-
tion detector as transmitter).
Select function on receiver: Select the group
function as described above on each receiver
to be integrated and con rm function on the
receiver.
Completing the confi guration: Brie y press the
cfg button on the transmitter.
Setting the switch-on time for the timer
The switch-on time on the receiver can be set in
stages for the function. Timer
The factory setting is 3 min.
Start confi guration.
If necessary, : Select select transmitter button
the button with the timer.
The Select transmitter button step does not
apply for radio motion detectors as transmit-
ters.
Select function on receiver: If the func-Timer
tion is displayed through the LED fl ashing fct
red (Table 5), keep the fct button on the re-
ceiver pressed for longer than 5 seconds, until
the cfg LED fl ashes briefl y.
The fl ashing fct LED shows the currently set
switch-on time - with a factory setting of 5x
(Table 9).
x number of fl ashes of
the fct LED
Switch-on time
1
1 s
2
30 s
3
1 min
4
2 min
5
3 min
6
5 min
7
15 min
8
30 min
9
1 h
10
3 h
Table 9: Settable switch-on times
Press the button.fct
Each short press of the fct button increases
the switch-on time by one step.
During the setting, the LED indicates the fct
switch-on time (Table 9) for orientation.
Press the button for longer than 2 seconds fct
to apply the desired switch-on time.
Completing the confi guration: Brie y press the
cfg button on the transmitter.
Resetting the KNX radio motion detector to
factory settings
The device is not in confi guration mode.
Keep the button pressed for longer than 10 cfg
seconds, until the LED switches from being cfg
red to ashing.
Release the button.cfg
The cfg LED fl ashes rapidly in red. The device
re-initialises itself. In the meantime, the cfg
LED turns red. After that, the LED goes out
and fl ashes 5x to indicate the compatibility. The
reset is has been completed. The process lasts
about 20 s.
This process deletes the complete con gura-
tion of the radio motion detector. Settings of the
insert (switch-on brightness level, load setting)
are not reset.
Operation
Result
Start confi guration
Briefl y press the cfg button on the radio motion
detector on the power supply (transmitter, slave).
T
150
90°
...
45° 4
...
90°
fct
c
If there is no further operation, the confi guration is
automatically ended after 10 minutes.
The LEDs on the radio motion detector cfg
(slave and master) light up in red colour.
T
150
90°
...
45° 4
...
90°
fct
cfg
T
150
90°
...
45° 4
...
90°
fct
cfg
All the receivers within radio range also display
the confi guration mode.
Select function on receiver
Briefl y press the cfg button on the radio motion
detector on the switch insert or fl ush-mounted
dimmer (master) to select the master-slave
function.
T
150
90°
...
45° 90°
fct
cfg
Only the master-slave function or delete can be
selected in this confi guration.
The fct LED fl ashes orange periodically
(see Table 5).
T
150
90° 45° 45° 90° ... ...
fct
cfg
Confi rm function on receiver
To save the allocation of command and function,
keep the fct button on the receiver (master)
pressed for more than 2 seconds.
T
150
90° 45° 90° ...
fct
cfg
> 2 s
The cfg LED fl ashes. After successful saving,
the LED signals the saved function. fct
Rapid ashing of the cfg LED indicates an
error.
Completing the confi guration
Briefl y press the cfg button on the transmitter
(slave).
T
150
90°
...
45° 4
...
90°
fct
c
The LEDs on the radio motion detectors and cfg
all receivers within radio range go out. The mas-
ter-slave confi guration has been executed.
Table 8: Executing the master-slave confi guration
Operation
Result
Start confi guration
Briefl y press the cfg button on the radio
motion detector.
T
150
90°
...
45° 4
...
90°
fct
c
If there is no further operation, the
confi guration is automatically ended after 10
minutes.
The LEDs on the radio motion detector and the cfg
receivers within radio range light up in red colour.
Radio motion detector (transmitter) and receiver are
in confi guration mode.
T
150
90°
...
45° 45°
...
90°
fct
cfg
cfg fc t
on
off
5 7 8321 4 6
L N S1
fct
cfg
Select function on receiver
Briefl y press the fct button several times on
the receiver to select the desired function
(see the receiver operating instructions).
cfg fct
on
off
5 7 8321 4 6
L N S1
fct
cfg
After each actuation, the fct LED displays a function.
If the radio motion detector has already been
confi gured with a function in a diff erent receiver
and/or the confi gured function is part of a group
control, only this function can be confi gured.
To change a function, the existing confi guration
needs to be deleted and the new one confi gured.
Confi rm function on receiver
To save the allocation of command and
function, press the fct button on the receiver
for longer than 2 seconds.
The cfg LED fl ashes. After a successful saving, the
fct LED signals the saved function.
Rapid ashing of the cfg LED indicates a
combination that is not possible or an error.
Completing the confi guration
Briefl y press the cfg button on the radio
motion detector.
T
150
90°
...
45° 4
...
90°
fct
c
The LEDs on the radio motion detector and all re-cfg
ceivers within radio range go out. The radio command
for the radio motion detector has been con gured.
Table 7: Con guration of KNX radio motion detector as a transmitter


Produktspezifikationen

Marke: Hager
Kategorie: Nicht kategorisiert
Modell: 85345126

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager 85345126 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Hager

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-