Greenlee DM-820A Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Greenlee DM-820A (83 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/83
INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D’INSTRUCTIONS
Read understand and all of the instructions and safety information in this
manual before operating or servicing this tool.
Lea entienda y todas las instrucciones y la información sobre seguridad
que aparecen en este manual, antes de manejar estas herramientas o
darles mantenimiento.
Lire attentivement bien comprendre et toutes les instructions et les
informations sur la sécurité de ce manuel avant d’utiliser ou de procéder à
l’entretien de cet outil.
Register this product at www.greenlee.com / Registre este producto en www.greenlee.com
Enregistrez votre produit en ligne, www.greenlee.com
DM-810A • DM-820A
DM-830A • DML-430A
Digital Multimeters
Multímetros digitales
Multimètres
numériques
52047799 REV 5 © 2019 Greenlee Tools, Inc. 10/19
2
Description
The Greenlee DM-810A, DM-820A, DM-830A, and DML-430A Digital Multimeters are hand-held
testing devices with the following measurement capabilities: AC and DC voltage, AC and DC current,
frequency, resistance, capacitance, and duty cycle of logic level signals. They also check diodes and
verify continuity. All meters feature true RMS AC measurements, a relative zero mode, data hold mode,
and an intelligent automatic power off. An optional optically isolated computer interface with software
facilitates the recording of readings from the meter to a computer.
Other specialized capabilities and functions common to all meters include:
• Dual display shows two measurements, such as AC voltage and frequency, at the same time.
• Backlighted LCD for reading in dim conditions.
• Beep-Jack™ audible warning alerts the user with a beep and an error message on the LCD if the
test lead is plugged into the or input terminal while the selector switch is not in the mA/µA A mA/µA
or position.A
• Bar graph display, which responds more quickly than the numeric display — useful for detecting
faulty contacts, potentiometer clicks, and signal spikes.
The DM-820A, DM-830A, and DML-430A multimeters have the following additional capabilities:
temperature (K-type thermocouples only); conductance; a crest function, which captures voltage or
current signal peaks; and a recording function, which stores the maximum, minimum, and difference
(maximum-minimum) input readings. The DM-820A and DM-830A record function can also calculate
the average reading. These two models also have non-contact and single-probe voltage detection.
The DM-830A and the DML-430A multimeters have an AutoCheck™ function for automatic selection
of AC voltage, DC voltage, and resistance with low input impedance to mask “ghost voltages. Both
multimeters feature a T1-T2 function, which can measure and display two temperatures and calculate
the difference. They also feature AC + DC true RMS measurement capability. The DM-830A has a dBm
function with selectable reference impedances. The DML-430A has the capability to store data.
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction
manual and any markings on the tool provide information for avoiding hazards and unsafe practices
related to the use of this tool. Observe all of the safety information provided.
Purpose of This Manual
This instruction manual is intended to familiarize all personnel with the safe operation and maintenance
procedures for the Greenlee DM-810A, DM-820A, DM-830A, and DML-430A Digital Multimeters.
Keep this manual available to all personnel. Replacement manuals are available upon request at no
charge at www.greenlee.com.
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
DM-810A • DM-820A • DM-830A • DML-430A
3
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an
injury or property damage. The signal word, defined below, indicates the severity of the hazard.
The message after the signal word provides information for preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage.
Read understand and this material before operating or servicing this
equipment. Failure to understand how to safely operate this tool could result in
an accident causing serious injury or death.
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Important Safety Information
All specifications are nominal and may change as design improvements occur. Greenlee Tools, Inc. shall not be liable
for damages resulting from misapplication or misuse of its products.
® Registered: The color green for electrical test instruments is a registered trademark of Greenlee Tools, Inc.
AutoCheck and Beep-Jack are trademarks of BTC.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
KEEP THIS MANUAL


Produktspezifikationen

Marke: Greenlee
Kategorie: Multimeter
Modell: DM-820A

Brauchst du Hilfe?

Wenn Sie Hilfe mit Greenlee DM-820A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Multimeter Greenlee

Bedienungsanleitung Multimeter

Neueste Bedienungsanleitung für -Kategorien-