Gre PP200 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Gre PP200 (48 Seiten) in der Kategorie Schwimmbadpumpen. Dieser Bedienungsanleitung war für 29 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/48
We reserve to change all of part of the articles or contents of this document, without prior notice.
Nos reservamos el derecho de cambiar total o parcialmente las características de nuestros artículos o contenido de este documento sin previo aviso.
Nous nous réservons le droit de modier totalement oru en partie les caracteristiques de nos articles ou le contenu de ce document san pré avis.
Wir behalten uns das recht vor die eigenschaften unserer produkte oder den inhalt diese prospektes teilweise oder wollstanding, ohne vorherige benachichtigung su andern.
Ci riservamo il diritto di cambiare totalemente o parzialmente le caratteristiche tecniche dei nostri prodotti ed il contenuto di questo documento senza nessum preavviso.
Wij behouden ons het recht voor geheel of gedeeltelijk de kenmerken van onze artikelen of de inhouk van deze handleiding zonder voorafgaand bericht te wijzigen.
Reservamo-nos no dereito de alterar, total ou parcialmente as caracteristicas os nossos artigos ou o conteúdo deste documento sem aviso prévio.
PP100 PP150 PP200
HIPP100/150/200.13
DISTRIBUIDO POR : MANUFACTURAS GRE S.A. ARITZ BIDEA Nº 57, BELAKO INDUSTRIALDEA, APARTADO 69 - 48100 MUNGUIA (VIZCAYA) ESPAÑA, Nº Reg. Ind. 48-06762
MADE IN CHINA
Self-priming SWIMMING POOL PUMP
BOMBA DE PISCINA autocebante
POMPE DE PISCINE auto-amorçante
Selbstansaugende SCHWIMMBADPUMPE
POMPA DI PISCINA auto-aspirante
Zelfaanzuigende ZWEMBADPOMP
BOMBA PISCINA autocomeçando
1 - 1,5 - 2 CV
EN ES FR DE IT NL PT
nº Description Descripción Description Beschreibung: Descrizione: Beschrijving: Descrição
1 Motor Motor Moteur Motor Motore Motor Motor
2 O-ring seal for
drive
Junta tórica
impulsión
Joint thorique
refoulement
O-Ring des Antriebs Guarnizione
impulso
O-ring impuls Tampão impulso
3 Pre-lter
cover
Tapa de
preltro
Buse Vorlterdeckel Coperchio
preltro
Deksel van de
voorlter
Tampa pre-ltro
4 Pre-lter
basket
Cesto del
preltro
Panier du préltre Vorlterkorb Canestro preltro Korf van de
voorlter
Cesto pre-ltro
5 O-ring seal for
pre-lter
Junta tórica
del preltro
Joint thorique de
la buse
O-Ring für Vorlter Guarnizione
preltro
O-ring voor
voorlter
Junta pre-ltro
6 O-ring seal for
suction
Junta tórica
aspiración
Joint thorique
aspiration
O-Ring für den
Sauger
Guarnizione
aspirazione
O-ring voor
aanzuiging
Tampão
aspiração
7 Purging plug Tapón de
purga
Bouchon de
vindage
Abussdeckel Tappo di scario Aftapplug Tampão
desaguamento
8 Purging plug
seal
Junta tapón
de purga
Joint du bouchon
de vinfage
Dichtung des
Abussdeckels
Guarnizione tappo
di scarico
Dichting
aftapplug
Junta tampão
desaguamento
9 Casing Carcasa Enveloppe Gehäuse Corpo pompa Behuizing Corpo bomba
10 O-ring seal Junta tórica Joint thorique O-Ring Guarnizione O-ring Tampão
11 Diuser Difusor Diuseur Diusor Diusore Diusor Difusor
12 Air-screw Helice Hélice Helix Turbina Schroef Turbina
13 Motor
assembly
plate
Placa de
montaje del
motor
Plaque de
montage du
moteur
Montageabdeckung
des Motors
Targa
d’assemblagio di
motore
Monteerbasis
voor motor
Placa da
montagem do
motor
EN- Self-priming swimming pool pump
This mode allows making a correct installation with optimal results of your swimming pool pump. Carefully
read this instruction manual.
Your new pump is a one-stage self-priming, centrifugal pump, designed for use with a swimming-pool
filtering system. It is designed to be used with clean water for temperatures between 5 ºC and 35 ºC. It is
manufactured from high quality materials subject to strict hydraulic and electrical tests. A correct installation
of this pump is assured by following the instructions from this manual. We decline all responsibility for
damages caused by use different to that explained in this instruction manual.
IMPORTANT
This manual contains basic information on the safety measures to be adopted during installation and start-
up. The fitter and the user must therefore read the instructions before installation and start-up.
GENERAL SAFETY REGULATIONS
The machines indicated in this Manual are especially designed for the pre-filtering and recirculation
of water in swimming pools
Install them in line with the specific instructions for each installation
All modifications to the pump require prior authorisation from the manufacturer. Original spare parts
and accessories authorised by the manufacturer ensure greater safety. The pump manufacturer is
exempt from all liability regarding any damage caused by unauthorised spare parts or accessories.
When working on each machine or on the units linked to them, disconnect the unit from the power
supply and the startup devices, as the electrical parts of the pump are live during operation.
All assembly and maintenance work must be carried out by qualified and authorised personnel who
have carefully read the installation and service instructions.
To guarantee safety when operating the machine, you must comply with that set out in the
installation and service instructions.
In the event of defective operation or faults, contact your supplier or nearest representative.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified personin order to avoid
Make sure that water is unable to enter the motor or the live electrical parts.
Avoid contact at all times - even accidentally - with moving machine parts while the machine is
running and/or before it comes to a complete standstill
Wait for the machine to come to a halt before handling it.
Before any electrical or mechanical maintenance operation, disconnect the unit from the power
supply and block the start-up devices.
To reduce risk of injury, children should not use this product.
Do not bury the electric cable. Lay the cable so it cannot be damaged by machinery, like mowing
machines, etc.
Do not start the pump before it is correctly connected to the swimming pool.
To reduce risk of electric shock, change the electric cable immediately when damaged.
To reduce risks of electric shock, do not use extension cables to connect the pump to a power
supply. Connect it to a correctly installed electricity outlet.
Do not use the pump without water!
INSTALLATION
Only authorised and qualified personnel should install the pump and its cabling, respecting the
current legislation.
The pump should be installed horizontally, screwing it to the support, to avoid vibration and
unwanted noise.
The pump should be installed far from any corrosive or flammable products.
The pump should have sufficient drainage to avoid risk of flooding and should be protected from
excessive humidity.
Install independent water inlet and outlet valves.


Produktspezifikationen

Marke: Gre
Kategorie: Schwimmbadpumpen
Modell: PP200

Brauchst du Hilfe?

Wenn Sie Hilfe mit Gre PP200 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schwimmbadpumpen Gre

Andere Handbücher Gre