Operating Instructions
METRAOHM 10
Low-Impedance Measuring Instrument 3-447-118-03
1/2.24
METRAOHM 10 Gossen Metrawatt GmbH
Content
1 Safety Instructions..................................................................................................................... 1
2 Applications ............................................................................................................................... 2
2.1 Intended Use / Use for Intended Purpose ............................................................................................................. 2
2.2 Use for Other than Intended Purpose.................................................................................................................... 2
2.3 Liability and Guarantee.......................................................................................................................................... 2
2.4 Opening the Instrument / Repairs.......................................................................................................................... 2
3 Documentation............................................... ................................. ........................................... 3
3.1 Identifiers .............................................................................................................................................................. 3
4 Getting Started............................................................. ................................. ............................. 3
5 The Instrument ............................................... ................................. ........................................... 4
5.1 Scope of Delivery .................................................................................................................................................. 4
5.2 Instrument Overview ............................................................................................................................................. 4
5.3 Relevant Standards............................................................................................................................................... 6
5.4 Technical Data ...................................................................................................................................................... 7
5.5 Measurement Specifications ................................................................................................................................. 7
6 Menu and Functions ........................... ................................................. ...................................... 9
6.1 User Interface........................................................................................................................................................ 9
6.2 Navigation........................................................................................................................................................... 10
6.3 Measurement Settings ........................................................................................................................................ 10
6.4 Setup Menu ........................................................................................................................................................ 11
7 Installation ............................. ........................................................................ ........................... 12
7.1 Unpacking the Instrument ................................................................................................................................... 12
7.2 Power Supply ..................................................................................................................................................... 12
8 Operation............................... ...................................................................................... ............. 14
8.1 Switching on/off .................................................................................................................................................. 14
8.2 Performing RLO 200 mA Measurement................................................................................................................ 14
8.3 Performing RLO 10A Limit Measurement ............................................................................................................. 16
8.4 Accessing the Help menu ................................................................................................................................... 19
8.5 Saving Measurement Results .............................................................................................................................. 19
8.6 Browsing Measurement Results.......................................................................................................................... 19
8.7 Saving Measurement Results to a PC ................................................................................................................. 19
8.8 Delete Measurement Results from the Memory ................................................................................................... 21
8.9 Reading Test Results on a PC............................................................................................................................. 21
9 Maintenance............................................................................................................................. 22
9.1 Cleaning.............................................................................................................................................................. 22
9.2 Troubleshooting .................................................................................................................................................. 22
9.3 Fuse Replacement .............................................................................................................................................. 22
9.4 Repair ................................................................................................................................................................. 22
9.5 Calibration........................................................................................................................................................... 22
10 Contact, Support and Service................ ................ ................................. ................. ............... 24
11 CE Declaration ............................. ................. ................................................. ................ .......... 25
12 Disposal and Environmental Protection .......................................... ............................. .......... 25
1
Gossen Metrawatt GmbH METRAOHM 10
1 Safety Instructions
General
• Carefully and completely read and adhere to these operating instructions.
The document can be found at http://www.gossenmetrawatt.com. Retain this document for future reference.
• Use only the specified accessories (included in delivery or listed as optional) with the instrument.
• Carefully and completely read and adhere to the product documentation of the optional accessories. Retain these doc-
uments for future reference.
• Observe and comply with all safety regulations which are applicable for your work environment.
Handling
• Use the instrument in undamaged condition only.
Inspect the instrument before use. Pay particular attention to damage, interrupted insulation or kinked cables. Damaged
components must be replaced immediately.
• Use the accessories and all cables in undamaged condition only.
Inspect accessories and all cables before use. Pay particular attention to damage, interrupted insulation or kinked
cables.
• If the instrument or an accessory doesn’t function flawlessly, remove it from operation and secure it against inadvertent
use.
• If the instrument or accessory is damaged during use, e.g. through falling, remove it from operation and secure it
against inadvertent use.
• If there are any signs of interior damage to the instrument or accessories (e.g. loose parts in the housing), permanently
remove the instrument/accessories from operation and secure them against inadvertent use.
Operating conditions
• Do not use the instrument after long periods of storage under unfavorable conditions (e.g. humidity, dust or extreme
temperature).
• Do not use the instrument after extraordinary stressing due to transport.
• The instrument must not be exposed to direct sunlight.
• Only use the instrument and the accessories in compliance with the specified technical data and under the specified
conditions (ambient conditions, IP protection class, measuring category, etc.).
• Do not use the instrument in potentially explosive atmospheres.
• The instrument and the included accessories may only be used for the tests/measurements described in the instru-
ment‘s documentation.
Electricity
• Do not use the instrument if the battery/fuse compartment cover has been removed.
Otherwise you risk touching dangerous voltages.
• Use batteries in undamaged condition only. Risk of explosion and fire in the case of damaged batteries!
Inspect the batteries before use. Pay particular attention to leaky and damaged batteries.
Fuses
• The instrument may only be used as long as the fuses are in flawless condition. Defective fuses must be replaced. Fuses
may only be replaced by our repair service department.
• Never bridge the fuses. Never put the fuses out of operation.
Data Security
• Always create a backup copy of your measurement/test data.
Produktspezifikationen
Marke: | Gossen Metrawatt |
Kategorie: | Meetapparatuur |
Modell: | METRAOHM 10 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Gossen Metrawatt METRAOHM 10 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Meetapparatuur Gossen Metrawatt
6 September 2024
Gossen Metrawatt METRALINE VT SENSE M611K Bedienungsanleitung
6 September 2024
4 September 2024
4 September 2024
2 September 2024
1 September 2024
1 September 2024
1 September 2024
1 September 2024
1 September 2024
Bedienungsanleitung Meetapparatuur
- Meetapparatuur Basetech
- Meetapparatuur LogiLink
- Meetapparatuur Panasonic
- Meetapparatuur Voltcraft
- Meetapparatuur Bosch
- Meetapparatuur Flex
- Meetapparatuur Laserliner
- Meetapparatuur Velleman
- Meetapparatuur Alecto
- Meetapparatuur Techno Line
- Meetapparatuur TFA
- Meetapparatuur Cocraft
- Meetapparatuur Einhell
- Meetapparatuur Pyle
- Meetapparatuur Mitsubishi
- Meetapparatuur Topcom
- Meetapparatuur Pioneer
- Meetapparatuur Megasat
- Meetapparatuur Continental Edison
- Meetapparatuur Hazet
- Meetapparatuur Perel
- Meetapparatuur Wago
- Meetapparatuur Lanaform
- Meetapparatuur Amprobe
- Meetapparatuur Metrix
- Meetapparatuur Westfalia
- Meetapparatuur Honeywell
- Meetapparatuur Reely
- Meetapparatuur Holzmann
- Meetapparatuur Midland
- Meetapparatuur Grohe
- Meetapparatuur ABB
- Meetapparatuur Kopp
- Meetapparatuur Hager
- Meetapparatuur Omnitronic
- Meetapparatuur Kyoritsu
- Meetapparatuur GW Instek
- Meetapparatuur Monacor
- Meetapparatuur KERN
- Meetapparatuur Brüder Mannesmann
- Meetapparatuur Aktobis
- Meetapparatuur Testo
- Meetapparatuur Albrecht
- Meetapparatuur Kogan
- Meetapparatuur Peak
- Meetapparatuur IDEAL
- Meetapparatuur TrueLife
- Meetapparatuur Carrier
- Meetapparatuur Testboy
- Meetapparatuur Fantini Cosmi
- Meetapparatuur Multimetrix
- Meetapparatuur IFM
- Meetapparatuur Extech
- Meetapparatuur BENNING
- Meetapparatuur Fluke
- Meetapparatuur Soler & Palau
- Meetapparatuur FLIR
- Meetapparatuur Vemer
- Meetapparatuur Oregon Scientific
- Meetapparatuur Finder
- Meetapparatuur Stabila
- Meetapparatuur Elgato
- Meetapparatuur Hikmicro
- Meetapparatuur Duro Pro
- Meetapparatuur Enda
- Meetapparatuur Entes
- Meetapparatuur Joy-it
- Meetapparatuur LaCie
- Meetapparatuur Maximum
- Meetapparatuur Megger
- Meetapparatuur PCE Instruments
- Meetapparatuur PICO
- Meetapparatuur RK Technology
- Meetapparatuur Sanwa
- Meetapparatuur Sonel
- Meetapparatuur Uni-T
- Meetapparatuur Wachendorff
- Meetapparatuur Owon
- Meetapparatuur PeakTech
- Meetapparatuur Siig
- Meetapparatuur Eltako
- Meetapparatuur H-Tronic
- Meetapparatuur Beha-Amprobe
- Meetapparatuur Chauvin Arnoux
- Meetapparatuur Electronics International
- Meetapparatuur Eastron
- Meetapparatuur Emko
- Meetapparatuur Wentronic
- Meetapparatuur Trumeter
- Meetapparatuur Etymotic
- Meetapparatuur ORNO
- Meetapparatuur TDE Instruments
- Meetapparatuur Apollo Ultrasonic
- Meetapparatuur Adwa
- Meetapparatuur Greisinger
- Meetapparatuur Clean Air Optima
- Meetapparatuur Motrona
- Meetapparatuur Atmel
- Meetapparatuur Tru Components
- Meetapparatuur Qubino
- Meetapparatuur Janitza
- Meetapparatuur CEM
- Meetapparatuur Klein Tools
- Meetapparatuur Tempo
- Meetapparatuur CIRCUTOR
- Meetapparatuur Seaward
- Meetapparatuur Dostmann Electronic
- Meetapparatuur ClimeMET
- Meetapparatuur Cliff
- Meetapparatuur Water-i.d.
- Meetapparatuur Tektronix
- Meetapparatuur Hanna
- Meetapparatuur Qualita
- Meetapparatuur MGL Avionics
- Meetapparatuur Aerospace Logic
- Meetapparatuur GMW
- Meetapparatuur SOEKS
- Meetapparatuur Murideo
- Meetapparatuur SecuTech
- Meetapparatuur NetPeppers
- Meetapparatuur SensoProtect
- Meetapparatuur ZKETECH
- Meetapparatuur LabNation
- Meetapparatuur MASIMO
- Meetapparatuur Milesight
- Meetapparatuur Ermenrich
- Meetapparatuur Siglent
- Meetapparatuur Noyafa
Neueste Bedienungsanleitung für -Kategorien-
17 September 2024
16 September 2024
15 September 2024
14 September 2024
14 September 2024
12 September 2024
12 September 2024
12 September 2024
11 September 2024
11 September 2024