Godox SKII Series Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Godox SKII Series (12 Seiten) in der Kategorie Blitz. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/12
Compact Studio Flash
705-SK2000-00 Made In China 说 明 手 册
Instruction Manual
中英文双语
Chinese English Bilingual
影 室 闪 光 灯
地址/ 深圳市宝安区福海街道塘尾社区耀川工业区厂房 栋 层至 层、 栋 层至 层Add: 2 1 4 4 1 4
1st to 4th Floor, Building 2/ 1st to 4th Floor, Building 4, Yaochuan Industrial Zone,
Tangwei Community, Fuhai Street, Bao’an District, Shenzhen 518103, China
电话/Tel: +86-755-29609320(8062) Fax: +86-755-25723423 传真/
邮箱/ E-mail: godox@godox.com http://www.godox.com
深圳市神牛摄影器材有限公司
GODOX Photo Equipment Co., Ltd.
FOREWORD
Thanks for choosing SKII series studio flash. It is a lightweight, compact and
durable flash with complete functions. Design for shooting studio portrait and
e-commerce product. This product is suitable for head shot, waist shoot, and
certificate photography, as well as product shooting, etc. It can also offer high
light, background light, or hair light in large studios and workshops. The SKII
flash offers:
CONTENTS
14 • Slave Trigger Model
15 • Buzz Function
15 • Key Combination
15 • Alarm Display
15 • Memory Function
15 • Wireless Control Function
17 • Tube Replacement
17 Technical Data
18 Maintenance
Built-in Godox 2.4G wireless X system
Precise output displayed on LCD panel, 40 steps from 1/16 to 1/1 (or 6.0 to 10.0)
Use optional X1, XT16 or FT-16 trigger to control the flash power ratio, modeling
lamp and buzzer, as well as flash triggering
Compact and lightweight body with Bowens mount to add almost any studio light
shapers
150W modeling lamp adjusts in 5% to 100% power levels
Outstanding output stability, no more than 2% shifts when under the same output
Anti-preflash function enables synchronization with cameras that have a one-
preflash firing system
Auto memory and recovery of adjusted panel settings
09 Foreword
10 Warning
Caution10
Names of Parts11
11 • Body
12 • LCD Panel
12 • Accessories
12 • Separately Sold Accessories
13 Operations
13 • Flash Preparation
13 • Power Connection
13 • Modeling Lamp
14 • Power Output Control
14 • Test Button
14 • Sync Triggering
14 • GR/CH Button
To prevent damage to the product or injury to you or to others, read the
following warnings in their entirety before using this product. Keep these
safety instructions where users can read them for ready reference.
Do not disassemble or modify. Should the product break down, send the
defective back to the authorized service center for inspection and maintenance.
Keep dry. Do not handle with wet hands, immerse in water, or expose to rain.
Keep out of reach of children.
Please put the device in a ventilation environment and keep the parts of lighting
and heat dissipation holes are unobstructed. Do not use in flammable
environment.
As this product adopts make and break device, please keep it easy to be used.
No touching the heating parts of this product.
Please turn off the power and wear insulated gloves before installing and
connecting accessories. When replacing the tube or modeling lamp, please
make sure that the tube is cool and wear insulated gloves to prevent burns.
Do not flash directly towards naked eyes (especially those of babies), otherwise
it may lead to visual impairment.
Disconnect from the power supply when it will not be used for an extended
period.
For continued protection against risk of fire replace only with same Type F8AL
250V fuse.
An apparatus with CLASS I construction shall be connected to a MAINS socket
outlet with a protective earthing connection.
The MAINS plug or an appliance coupler is used as the disconnect device, the
disconnect device shall remain readily operable.
After 30 continuous flashes at full power, the flash should be cooled down for
about 3 minutes. Overheating will occur if it is used continuously without cooling
down.
Do not keep using the modeling lamp for a long time; otherwise flammable
accessories attaching to flash head, e.g. softbox will get burnt. A 10-minute time
is recommended in this case. After 10 minutes, cool it down for 1 minute.
When using a snoot, do not keep the modeling lamp on for a long time or fire too
frequently (not over six times for one minute). Overheating will result in damages
for strobe housing and/or studio light.
Avoid sudden impacts as this can damage the flash tube and/or modeling lamp.
The apparatus shall not be exposed to tripping or splashing and that no objects
filled with liquids, such as vases, shall be placed on the apparatus.
Do not touch the area around this symbol since it is hot.
Warning
- 09 - - 10 -
Produktspezifikationen
Marke: | Godox |
Kategorie: | Blitz |
Modell: | SKII Series |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Godox SKII Series benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Blitz Godox
7 Oktober 2024
29 September 2024
19 September 2024
15 September 2024
6 September 2024
5 September 2024
5 September 2024
5 September 2024
5 September 2024
4 September 2024
Bedienungsanleitung Blitz
- Blitz LogiLink
- Blitz Sony
- Blitz Panasonic
- Blitz Canon
- Blitz Braun
- Blitz Metz
- Blitz Olympus
- Blitz Genaray
- Blitz Cullmann
- Blitz Fujifilm
- Blitz MINOX
- Blitz Nikon
- Blitz Sigma
- Blitz Yongnuo
- Blitz Konica-Minolta
- Blitz Leica
- Blitz Pentax
- Blitz Rollei
- Blitz SeaLife
- Blitz Pulsar
- Blitz Manfrotto
- Blitz EasyMaxx
- Blitz GVM
- Blitz Hähnel
- Blitz Dörr
- Blitz Ikan
- Blitz Kenko
- Blitz Neewer
- Blitz Nissin
- Blitz Quantum
- Blitz Sunpak
- Blitz Triopo
- Blitz Vivitar
- Blitz Elinchrom
- Blitz Profoto
- Blitz Vello
- Blitz Aputure
- Blitz Westcott
- Blitz Xantech
- Blitz Bolt
- Blitz Anton/Bauer
- Blitz PolarPro
- Blitz Lastolite
- Blitz ANDYCINE
- Blitz Ikelite
- Blitz COLBOR
- Blitz Goodram
- Blitz Xit
- Blitz Impact
- Blitz Rotolight
- Blitz Cactus
- Blitz Kaiser Fototechnik
- Blitz FoxFury
- Blitz Jinbei
- Blitz Quadralite
Neueste Bedienungsanleitung für -Kategorien-
8 Oktober 2024
3 Oktober 2024
1 Oktober 2024
1 Oktober 2024
16 September 2024
8 September 2024
8 September 2024
8 September 2024
7 September 2024
5 September 2024