Glyph StudioRAID Bedienungsanleitung
Glyph
Festplatten-Array
StudioRAID
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Glyph StudioRAID (9 Seiten) in der Kategorie Festplatten-Array. Dieser Bedienungsanleitung war fĂĽr 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/9
StudioRAID™ Manual
Tabletop FireWire 800, USB .0 and 3
eSATA enclosure with RAID RAID 0 1 and
Proprietary Notice and Disclaimer
Unless noted otherwise, this document and the information herein disclosed are proprietary to Glyph Technologies, 3736
Kellogg Rd., Cortland NY 13045 (“GLYPH”). Any person or entity to whom this document is furnished or having possession
thereof, by ac-ceptance, assumes custody thereof and agrees that the document is given in confidence and will not be copied or
reproduced in whole or in part, nor used or revealed to any person in any manner except to meet the purposes for which it was
delivered. Additional rights and obligations regarding this document and its contents may be defined by a separate written
agreement with GLYPH, and if so, such separate written agreement shall be controlling.
The information in this document is subject to change without notice, and should not be construed as a commitment by G YPH. L
Although G YPH will make every eort to inform users of substantive errors, G YPH disclaims all liability for any loss or damage L L
resulting from the use of this manual or any software described herein, including without limitation contingent, special, or inci-
dental liability.
© Specifications subject to Glyph 2015 Technologies. All rights reserved. Glyph are change without notice. and the
Glyph registered Technologies. and logo are trademarks of Glyph All other brands product names mentioned are trademarks
of their respective holders.
Contacting Glyph
Please use the following contact information to contact Glyph and its distributors.
Glyph USA offers phone support Monday through Friday, :00 am to :00 PM Eastern 8 5
Time.
Note: DO NOT ship any return goods to the mailing addresses below unless you have a valid RMA number.
All goods will be refused delivery unless a valid RMA number is displayed on the outside of the package.
United States of America
Glyph Technologies
3726 Kellogg Rd.
Cortland, NY 13045
USA
Phone: +1 607-275-0345
Fax: +1 607-275-9464
www.glyphtech.com
Sales Contact
sales@glyphtech.com
Technical Support:
tech@glyphtech.com
Unpacking Your StudioRAID
Your Glyph and accessories are packaged in a sturdy shipping container. Please inspect the StudioRAID
con-tainer for evidence of shipping damage and mishandling. If the container is damaged, file a report with
the carrier or dealer immediately. Do not attempt to unpack and operate your until the carrier StudioRAID
or dealer confirms the damage. If the container is in good condition, proceed with unpacking the
StudioRAID. Verify that all of the items described in the next section are present and in good condition. If
any of the items you expect to find in your container is missing or damaged, contact the dealer before
proceeding any further.
In any case, do keep the shipping container and all packing materials in a safe place.
The package includes:StudioRAID
StudioRAID Enclosure
FireWire 800 Cable
USB .0 Cable 3
IEC Power Cable
About the and Drive ModesStudioRAID
The enclosure contains two hard disk drives, which function as one single volume. StudioRAID It supports
two ) and drive modes: RAID 1 (mirroring RAID 0 (striping). Each drive mode has its own advantages,
depending upon the application.
RAID 1 (mirroring) oers data redundancy and real-time backup by writing the same data to the
two hard drives at the same time. Should a drive failure happen, data is still available on the remain-
ing drive. In RAID 1 mode, the two drives are seen by the computer as one volume, but with half the
capacity. For example, a 1TB will be seen as a 500GB drive. Reading and writing occurs StudioRAID
on both drives simultaneously so that each of the drives contains exactly the same data, mirroring
each other. provide If either of the should fail the other is seamlessly continue drives there to to
operation.
RAID 0 (striping) increases the performance of the drive system by spreading the data across two
drives. RAID 0 is a proven technology for editing video, working with huge graphics les, sound
libraries, and streaming instruments that play hundreds of samples simultaneously. RAID 0 is the de-
fault shipping drive mode. In RAID 0 (striping) mode, the two drives are seen by the computer as one
large drive, and reading and writing occurs on both drives simultaneously. It is designed to increase
the performance and data throughput of the drive system. The built-in RAID controller StudioRAID's
splits each piece of data across both of the drives in segments and distributes the I/O burden. Since
data is written without any form of parity data-checking, it allows for the fastest data transfer of all
other RAID levels. However, if one drive becomes damaged, the data on both drives can become
cor-rupted. RAID 0 is not redundant or fault tolerant like RAID level but the trade off is that it’s the 1,
fastest of all RAID levels. MAKE SURE TO BACKUP YOUR DATA OFTEN!
Produktspezifikationen
Marke: | Glyph |
Kategorie: | Festplatten-Array |
Modell: | StudioRAID |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Glyph StudioRAID benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Festplatten-Array Glyph
30 August 2024
Bedienungsanleitung Festplatten-Array
- Festplatten-Array HP
- Festplatten-Array Sharkoon
- Festplatten-Array Buffalo
- Festplatten-Array Netgear
- Festplatten-Array Fantec
- Festplatten-Array Hitachi
- Festplatten-Array AIC
- Festplatten-Array Icy Box
- Festplatten-Array Dell
- Festplatten-Array Western Digital
- Festplatten-Array Supermicro
- Festplatten-Array SilverStone
- Festplatten-Array Seagate
- Festplatten-Array Fujitsu
- Festplatten-Array D-Link
- Festplatten-Array QNAP
- Festplatten-Array Synology
- Festplatten-Array Tandberg Data
- Festplatten-Array LaCie
- Festplatten-Array Intel
- Festplatten-Array Sonnet
- Festplatten-Array Vantec
- Festplatten-Array Addonics
- Festplatten-Array HGST
- Festplatten-Array OWC
- Festplatten-Array Rocstor
- Festplatten-Array Raidsonic
- Festplatten-Array G-Technology
- Festplatten-Array Infortrend
- Festplatten-Array Areca
- Festplatten-Array Promise Technology
- Festplatten-Array IDIS
- Festplatten-Array IStarUSA
- Festplatten-Array Enhance
- Festplatten-Array Icy Dock
- Festplatten-Array CRU
Neueste Bedienungsanleitung fĂĽr -Kategorien-
11 Oktober 2024
22 September 2024
18 September 2024
13 September 2024
5 September 2024
5 September 2024
2 September 2024
31 August 2024
31 August 2024
30 August 2024