Genelec 7350A Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Genelec 7350A (4 Seiten) in der Kategorie Monitor. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Genelec 7350A
Smart Active Subwoofer
Operating Manual
7350A
General Description
The Genelec 7350A smart active subwoofer
is a very compact low frequency monitor,
intended to extend the bass reproduction
of Genelec 8320A active monitors in stereo
or multichannel applications and 8330A in
stereo applications. The 7350A can be used
in multichannel applications with the 8330A
when SPL capacity of the 7350A subwoofer
suits the application. 7350A can be used a
general purpose Smart Subwoofer solution
with any analog or digital audio monitor.
Driver
The 7350A contains one 205 mm (8”) low
frequency driver housed in a Genelecs pro-
prietary Laminar Spiral EnclosureTM (LSETM)
bass reflex cabinet.
Amplifier
The D Class power amplifier outputs 150 W
with very low THD and IM distortion. Driver
overload, amplifier thermal overload, and
driver short circuit protections are included
in the amplifier electronics.
Installation
The subwoofer is supplied with a mains
cable, a GLM network cable, and this operat-
ing manual. Inspect the subwoofer to ensure
that it has not been damaged in transport.
Check that the mains voltage marking on
the device matches your local mains voltage.
Before connecting turn off the subwoofer
and the monitors. Once all connections have
been made, the subwoofer and monitors can
be powered up.
Audio Connections
Audio connections are made with balanced
XLR cables. The 7350A has IN/OUT connec-
tor pairs for five analogue channels and an
analogue LFE channel input. There is also
one IN/OUT connector pair for AES/EBU
digital audio signal.
Connect signal cables from your audio
source to the female XLR "IN" connectors.
Next, connect XLR cables from the corre-
sponding "OUT" male XLR connectors to the
input connector of each monitor.
Connect the "LFE IN" connector to the LFE
or .1 output of a multichannel sound source.
The digital audio input (DIGITAL IN)
accepts a male XLR connector carrying an
AES/EBU formatted signal. The digital audio
signal can be routed to the next monitor or
subwoofer (DIGITAL OUT). The AES/EBU
digital audio subframe A or B is selected
using the GLM software. The default setting
for the subframe selection A+B meaning that
the subwoofer reproduces audio in both sub-
frames.
GLM Network Connection
Using the GLM Adapter all monitors and
subwoofers in the system are connected to a
computer running the Genelec Loudspeaker
Manager (GLM) software (See Figure 3.) A
GLM network cable with RJ45 connectors is
supplied with each monitor and subwoofer
for this. Start control network cabling from
the GLM Adapter to the first monitor or
subwoofer. Continue daisy-chaining to all
monitors and subwoofers in the system.
No special sequence is necessary. You can
choose the easiest control network cabling
route.
Settings and Acoustic
Calibration
The 7350A subwoofer and Smart Active
Monitors are extremely exible in compensat-
ing the acoustic influences of the room where
the products have been installed and support
automated setup using the GLM User Kit and
software. The 7350A subwoofer is compatible
with GLM 2.0 and later.
The GLM software can be downloaded
from Genelec web site (www.genelec.com/
glm). The GLM 2.0 User Kit is needed for
the setup. The User Kit contains the GLM
Adapter and GLM measurement microphone.
The GLM Adapter is connected to the
computer USB port and the GLM network. If
the 7350A is the only smart device, the GLM
Adapter is only connected to the subwoofer.
The GLM measurement microphone is
placed at the listening location.
Execute the setup process in the GLM
software to align and set up the subwoofer
and any other smart devices as a system on
the GLM network. After calibration, keep the
computer connected to maintain the settings
or save the settings to the subwoofer using
the GLM 2.0 software.
ISSTM Autostart Function
Intelligent Signal SensingTM (ISSTM) enables
less than 0.5 W standby power consumption.
As a factory default, the ISS function is
disabled. The ISS function can be enabled
and configured in the GLM software by click-
ing the “ISS Power Saving” pulldown menu.
This menu also provides selection of the
time before entering standby. Playback auto-
matically resumes once an input signal is
detected. There is a slight delay before play-
back resumes.
Placement in the Room
Subwoofer placement affects the frequency
response and sound level dramatically. At
low frequencies the acoustical effects of the
room are strong. Even a slight change in the
subwoofer's location can make a marked
difference. The placement affects the fre-
queny response, phase difference between
the monitors and subwoofer, as well as the
subwoofer roll-off rate.
Place the subwoofer on the floor, slightly
offset from the room centre line, at the front
wall. Distance to the front wall should be
less than 0.6 m (24 in) measured from the
subwoofer's driver. Proximity to the wall
can increase acoustic output and maximum
sound level. Larger distance to the wall can
cause acoustical cancellation and reduce
subwoofer output.
Moving the subwoofer slightly to the left
or right can improve the flatness of the fre-
quency response. Positioning the subwoofer
close to a corner can boost the bass level
more but may cause asymmetrical sound
imaging at low frequencies.
Use the GLM to automatically calibrate
the frequency response of the subwoofer for
maximal flatness. If the monitors are Smart
Monitors, GLM also automatically aligns the
output level and crossover phase in relation
to the monitors.
Minimum Clearances to
Walls or Other Objects
Do not cover the driver of the subwoofer.
Allow at least 10 cm (4 in) of space in front of
the driver grille.
Thick carpets under the subwoofer can
block ventilation.
Genelec 7350A Smart Active Subwoofer
The bass reflex port (located opposite of
the connector panel) should have a minimum
clearance of 7.5 cm (3 in) to ensure sufficient
bass reflex system sound output.
Flush Mounting the
Subwoofer
When the subwoofer is flush mounted into a
recess in a wall or in a cabinet, ensure ampli-
fier cooling and unrestricted airflow from the
bass reflex port. Make the recess at least 7.5
cm (3 in) wider than the subwoofer. Place
the subwoofer to the right side of the recess
with the driver facing the room. This leaves
sufficient space at the bass reflex port.
The height and depth of the recess should
not be bigger than what is needed to t the
subwoofer.
Safety Considerations
Genelec 7350A subwoofer has been
designed in accordance with international
safety standards. However, to ensure safe
operation and maintain the unit in safe oper-
ating condition, the following warnings and
cautions must be observed:
• Servicing and adjustment must only be
performed by qualified service personnel.
The subwoofer cabinet or electronics unit
must not be opened.
• Do not use this subwoofer with an
unearthed mains cable or an unearthed
mains connection as this may compromise
electrical safety.
• Do not expose the subwoofer to water
or moisture. Do not place any objectslled
with liquid, such as vases, on the subwoofer
or near it.
• This subwoofer is capable of producing
sound pressure levels in excess of 85 dB
SPL, which may cause permanent hearing
damage.
• Free flow of air around the subwoofer is
necessary to maintain sufficient cooling. Do
not obstruct airflow around the subwoofer.
• Note that the amplifier is not completely
disconnected from the AC mains service
unless the mains power cord is removed
from the amplifier or the mains outlet.
Warning!
This subwoofer is capable of delivering sound
pressure levels in excess of 85 dB, which
may cause permanent hearing damage.
Figure 2. Flush mounting the subwoofer.
Note the clearance needed on the reflex
port side.
RISQUE D E CHOC ÉLECT RIQUE. NE S OUVRIR. NE S EXPOSEPA PA R À L 'EAU OU L'HUMIDIT É. AUCUN
COMPOSANT À L 'INT ÉRIEUR REMPLAÇABLE PAR L' UTILIS EUR. ADRESSER TOUT E RÉPARAT IONÀAT
UN PERSONNEL QUALIFIÉ. CET APPAREILDOIT ÊTRE RACCORDÉ À LA T ERRE.
LAIT E ON LIIT ETT ÄVÄSUOJ AMAADOIT USKOSKETT IMILLA VARUST ET TUU N PISTORASIAAN.
APPARAT ET MÅ T ILKOPLES JORDET ST IKKONTAKT. APPARAT EN SKALL ANSLUT AS TILL J ORDAT UT T AG.
ON
MADE IN FINLAND
www.genelec.com
7350A SMART ACTIVE SUBWOOFER
MAGNETICALLY SHIELDED
LFE IN
WARNING
ELECT RIC SHOCK HAZAR D. DO
NOT OPEN. DO NOT SUBJECT
T OWATER OR MOIST URE. N O
USER SERVICEABLE PART S
INSIDE. REFER SERVICING T O
QUALIFIED PERSONNEL. USE
EART HED MAINS C ONNECT ION
ONLY.
SERIAL
NUMBER
MAINS INPUT
50 / 60 Hz
120 W 230 V~
GLM NETWORK
AVERTISSEMENT
IN 1 IN 2OUT 1 OUT 2 OUT IN
IN 3 IN 4OUT 3 OUT 4 IN 5 OUT 5
DIGI LTA
ANALOG
710127
T HIS DEVICE COMPLIES
WITH FCC 15 ANDPART
CANADIAN ICES-0 03 R ADIO
FREQUENCY CLASS B
EMISSIONR EQUIREMENT S.
REFER OPERAT INGTO
MANUAL FOR FULL
INFORM ION.AT
TEST OUT 1 TEST OUT 2
ANALOG
SIGNAL
CONNECTORS
DIGITAL SIGNAL
CONNECTORS
GLM NETWORK
CONNECTORS
POWER
SWITCH
MAINS
INPUT
Maintenance
No user serviceable parts are inside the
subwoofer. Any maintenance of the unit may
only be performed by qualied service per-
sonnel.
Guarantee
This product is supplied with a two year guar-
antee against manufacturing faults or defects
that might alter the performance of the unit.
Refer to supplier for full sales and guarantee
terms.
Figure 1. Connector panel of the 7350A
Figure 3. GLM Network cabling. Audio cabling not shown.
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM T ERMINA RT O
COMPUTER
RUNNING
GLM SOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
SUBWOOFER


Produktspezifikationen

Marke: Genelec
Kategorie: Monitor
Modell: 7350A

Brauchst du Hilfe?

Wenn Sie Hilfe mit Genelec 7350A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Monitor Genelec

Bedienungsanleitung Monitor

Neueste Bedienungsanleitung für -Kategorien-