Gembird EG-EM1 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Gembird EG-EM1 (4 Seiten) in der Kategorie Elektriciteit meiter. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
Energy Meter
Model No. EG-EM1
Introduction
With the Energy Meter, you are now able to determine power costs of your power loads in the easiest way.
Proper use
The measurement range of the Energy Meter extends from 5W to 3680W. If values fall below or exceed
these limit values, exact measurement are no longer possible. Also the device could not be overloaded,
otherwise will be destroyed. There will be alarm for the power overloading.
The Energy Meter has been developed for monitoring and measuring electrical loads.
The Energy Meter is only certified for operation at 230V AC.
Only power loads with a power supply of 230V AC 50/60Hz may be connected.
The maximum power of any connected load may not exceed 3680W (max. current 16A).
It is only suitable for electrical appliances with resistive load.
Operation of the Energy Meter is only permitted in interior spaces and dry environments, Usage in the
open air is strictly forbidden!
Safety Instructions
This device is not a toy and does not belong to the hands of children.
Only connect the Energy Meter to certified protected contact outlets 230V AC 50/60Hz (10/16A) with a
ground wire.
The connected load may not exceed 3680W(16A).
The recommended operating temperature is between +5 to +40 . High temperature may lead to
overheating and can thereby permanently destroy the Energy Meter.
Avoid operating under adverse environmental temperatures or near flammable gases, vapour and dust.
For reasons of safety, never allow the device to be operated when in wet or in a damp environment
When cleaning or servicing, the device must be disconnected from every source of operating voltage.
Condensers in the device may still be charged, even if the device was disconnected from all voltage
sources.
Do not insert needles, metals or any other objects into the device.
Properties
Display current time (24 hours type), week, load power and cost tariff.
Display total used energy and accrued energy cost.
Display total recorded time, total ON time and percentage .
Dual programmable power tariffs.
Displaying line of power Blinks (fig4,the second line) if the load power is over 3680W
Connection, operation settings
Before you connect the Energy Meter to an outlet or power or power load, condensers in the device will be
charged. Five minutes later, the condensers will have enough power to sustain the normal display of LCD
then the current time and your desired power tariff must be set.
Suggestion:
It is better to take 8-12 hours to charge the condensers fully for the first time, in order
to make the rechargeable Li-batteries to achieve optimum performance.
The procedure for entering the time and power tariff is described as following:
A. The setting of current time and week
1. Press“+” “-“ buttons together to enter into system setting, first setting
is the current time.
2. With “+” button to increase the value of the blinking position, while
with “-“ button to decrease the value of the blinking position.
3. Press “MODE” button to select next position.
4. After the setting of week, press “MODE” button, the system will enter
into the setting of cost tariff 1.
B. The setting of cost tariff 1
1. Set the effect time of cost tariff 1.
2. Set the value of tariff 1.(it is cent as unit, such as: 10cent)
3. With “+button to increase the value of the blinking position, while
with “-“ button to decrease the value of the blinking position.
4. Press “MODE” button to select next position.
5. Press “MODE” button, the system will enter into the setting of cost
tariff 2.
C. The setting of cost tariff 2
1. Set the effect time of cost tariff 2.
2. Set the value of tariff 2. .(it is cent as unit, such as: 10cent)
3. With “+” button to increase the value of the blinking position from 0 to
9,while with “-“ button to decrease the value of the blinking position.
4. Press “MODE” button to select next position.
5. Go on pressing the button “mode” until the display board of fig4
appears.
D. Press “MODE”, “+” “-” simultaneously to delete all data (the data of current time
and the week will not be deleted) after 5 seconds.
Introduction of display board
Three display boards are designed to display different figures, you can use “MODE” button to
select which board you want to browse.
1. Display of current time (24 hours type), week, load power and current cost tariff
2. Display of total record time, total used energy and accrued energy cost.
3. Display of total record time, total on time and percentage
Current cost tariff per hour
T
otal
measuring time with load
(ONh/RECh)

Produktspezifikationen

Marke: Gembird
Kategorie: Elektriciteit meiter
Modell: EG-EM1

Brauchst du Hilfe?

Wenn Sie Hilfe mit Gembird EG-EM1 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten