GE Profile PTD60EBSRWS Bedienungsanleitung

GE Wäschetrockner Profile PTD60EBSRWS

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für GE Profile PTD60EBSRWS (68 Seiten) in der Kategorie Wäschetrockner. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/68
Installation
Dryer
Instructions
If you have any questions, call GE Appliances at 800.GE.CARES
(800.432.2737) or GEAppliances.com visit our Website at:
In Canada, call 800.561.3344 or visit www.GEAppliances.ca
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT Save these instructions for
local electrical inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Install the clothes dryer according to the
manufacturer’s instructions and local codes.
Note to Installer Be sure to leave these
instructions with the Consumer.
Note to Consumer Keep these instructions for
future reference.
Clothes dryer installation must be performed by a
qualified installer.
This dryer must be exhausted to the outdoors.
Before the old dryer is removed from service or
discarded, remove the dryer door.
Service information and the wiring diagram are
located in the control console.
Do not allow children on or in the appliance. Close
supervision of children is necessary when the
appliance is used near children.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
Install the dryer where the temperature is above
50°F for satisfactory operation of the dryer control
system.
Remove and discard existing plastic or metal foil
duct and replace with UL-listed duct.
- Risk of Fire
Clothes dryer installation must be performed by a
qualified installer.
Install the clothes dryer according to these
instructions and local codes.
DO NOT install a clothes dryer with flexible plastic
venting materials. If flexible metal (semi-rigid or
foil-type) duct is installed, it must be UL-listed and
installed in accordance with the instructions found
in “Connecting the Dryer to House Vent” later in
this manual. Flexible venting materials are known
to collapse, be easily crushed and trap lint. These
conditions will obstruct dryer airflow and increase
the risk of fire.
DO NOT install or store this appliance in any
location where it could be exposed to water or
weather.
To reduce the risk of severe injury or death, follow
all installation instructions.
Save these instructions. (Installers: Be sure to
leave these instructions with the customer.)
WARNING
In the Commonwealth of Massachusetts,
the following installation instructions apply:
Installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the State.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not
exceed 4 feet (1.2 m).
FOR GAS DRYERS ONLY
12-21 GEA
31-3000245-2
Installation Instructions
Tilt the dryer sideways and remove the foam shipping pads by pulling at the sides and
breaking them away from the dryer legs. Be sure to remove all of the foam pieces around
the legs.
Remove the bag containing the literature.
UNPACKING YOUR DRYER
DRYER
DIMENSIONS
2
43 7/8”
(112 cm)
27”
(68.8 cm)
Front View
ACCESSORIES:
Order on-line at , 24 hours a day or GEApplianceparts.com
by phone at during normal business hours.877.959.8688
Part Number Accessory
PM14X10056
Dryer Door Opening Vent Brush
WX14X10007
LintEater™ Dryer Rotary Tube Brush
PM08X10085
Flexible Metal Dryer Transition Duct
4 5/8”
(11.7 cm)
31”
(79 cm)
4 1/4”
(10.8 cm)
Side View
43 7/8”
(112 cm)
GE Appliances strongly recommends the use of factory
specified parts. These hoses are manufactured and tested
to meet GE Appliances specifications.
GE Appliances strongly recommends the use of new water
supply hoses. Hoses degrade over time and need to be
replaced every 5
years to reduce the risk of hose failures
and water damage.
Parts and Accessories
Order on-line at , 24 hours a day GEApplianceparts.com
or by phone at during normal business hours.877.959.8688
STEAM WATER HOSES (for steam dryer models only):
Part Number Accessory
WE25X20060
Complete Kit (hoses, Y-adapter, washers)
or
WE49X25794
Kit (Short hose, Y-adapter, washers)
and
WE1M847 Long Hose
OR SEPARATELY
WE1M847 Long Hose and
WE1M848 Short Hose
Installation Instructions
MOBILE OR MANUFACTURED
HOME INSTALLATION
Installation MUST conform to the
MANUFACTURED HOME CONSTRUCTION
AND SAFETY STANDARD, TITLE 24, PART
3280 or STANDARD FOR MOBILE HOMES
CAN/CSA-Z240 MH, or, when such standards
are not applicable, with AMERICAN NATIONAL
STANDARD FOR MOBILE HOME, ANSI/NFPA
NO. 501B.
The dryer MUST be vented to the outdoors.
The exhaust vent MUST be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
DO NOT use sheet metal screws or other
fastening devices which extend into the interior of
the exhaust vent.
Provide an opening with a free area of at least 25
square inches (63 cm2) for introduction of outside
air into the dryer room.
See the sections for electrical connection information.
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
The dryer MUST be vented to the outdoors.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” (0 cm) either side*
1” (2,54 cm) front
1” (2,54 cm) rear
1” (2,54 cm) top
* For improved performance, a 1/2” (12.7 mm)
clearance is suggested on each side.
The rear of the dryer should face a wall.
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches (387
cm2) of open area. If the closet contains both a
washer and a dryer, doors must contain a minimum
of 120 square inches (774 cm2) of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, THE CONFIGURATION
OF THE DUCTING MAY REQUIRE GREATER
CLEARANCE.
Gas Dryers Only:
No other fuel burning appliance shall be installed in
the same closet as a gas dryer.
The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than 1/2 psi (3.5 kPa).
A 1/8” (3.2 mm) NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
MINIMUM CLEARANCE OTHER
THAN ALCOVE OR CLOSET
INSTALLATION
Minimum clearance to combustible surfaces and for
air opening are: 0” (0 cm) both sides*, 1(2,54 cm)
rear and 1” (2,54 cm) top.
* For improved performance, a 1/2” (12.7 mm)
clearance is suggested on each side.
The rear of the dryer should face a wall.
Consideration must be given to provide adequate
clearance for installation and service.
- Explosion Hazard
WARNING
3


Produktspezifikationen

Marke: GE
Kategorie: Wäschetrockner
Modell: Profile PTD60EBSRWS

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE Profile PTD60EBSRWS benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wäschetrockner GE

Bedienungsanleitung Wäschetrockner

Neueste Bedienungsanleitung für -Kategorien-