Installation
Instructions
Electric Dryer
37
BEFORE YOU BEGIN
TOOLS YOU
WILL NEED
MATERIALS YOU WILL NEED
FOR YOUR SAFETY:
WARNING
Read these instructions completely and carefully.
PHILLIPS SCREWDRIVER
SLIP JOINT PLIERS
LEVEL
GLOVES
SAFETY GLASSES DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
UL RATED 120/240V, 30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG TYPE
AS PER THE HOUSE
RECEPTACLE BEFORE
PURCHASING LINE CORD.
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST HOOD
3/4" STRAIN RELIEF
UL RECOGNIZED
• Use only rigid metal or flexible metal 4-in. diameter
ductwork for exhausting to the outdoors. Never
use plastic or other combustible, easy-to-puncture ductwork.
• This appliance must be properly grounded and installed
as described in these instructions.
• Do not install or store appliance in an area where it
will be exposed to water and/or weather
• Install the dryer where the temperature is above 50ºF
for satisfactory operation of the dryer control system.
4" DIA. METAL
ELBOW
IMPORTANT - Save these
instructions for local inspector’s use.
IMPORTANT - Observe all
governing codes and ordinances.
Note to Installer - Be sure to leave these instructions with
the customer.
Note to Customer - Keep these instructions with your Use
and Care Book for future reference.
Exhausting the dryer to the outdoors is strongly recom-
mended to prevent large amounts of moisture from being
blown into the room.
Before the old dryer is removed from service or discarded,
remove the dryer door.
Service information and the wiring diagram are located in
the control console.
Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance is
used near children.
NOTE: Installation and service of this dryer
requires basic mechanical and electrical skills.
It is your responsibility to contact a qualified
installer to make the electrical connections.
Step 1 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3 Remove the Foam Shipping Pads (see section 1).
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply
and Venting.
Step 9 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
Questions on Installation? Call: 1-800-GECARES (US)
or Visit our Web site at:
www.GEAppliances.com (US)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL DUCT
(IF NEEDED)
FLAT BLADE SCREWDRIVER
DUCT TAPE
49
Installation Instructions
1 PREPARING FOR INSTALLATION
OF NEW DRYER
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for installation and service.
2 ELECTRICAL CONNECTION
INFORMATION
EXTERNAL
DUCT
OPENING
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
2
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRI-
CAL CODE, ANSI/NFPA NO. 70.
WARNING - TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:
ELECTRICAL REQUIREMENTS
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
This dryer must be connected to an individual branch circuit,
protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz,
30 amp circuit is required.
If the electric supply does not meet the above specifications, then
call a licensed electrician.
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run
with the circuit conductors and connected to the equipment-
grounding terminal on the appliance.
NOTE: Since January 1, 1996, the National Electric Code
requires that new constructions utilize a 4 wire connection
to an electric dryer.
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
DUCT TAPE OR
DUCT CLAMP
DUCT TAPE OR
DUCT CLAMP
4" METAL DUCT
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
3
Installation Instructions
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove the power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord
entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N). 6. Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet
rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
CONNECTING DRYER USING 3-WIRE
CONNECTION
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER 3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green
ground screw for step 7. 5. Install 3/4 in. UL recognized strain relief to power
cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green ground
screw (hole above strain relief bracket). Tighten all
terminal block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
3 EXHAUST INFORMATION
WARNING - USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED
IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The MAXIMUM ALLOWABLE length of the exhaust system
depends upon the type of duct, number of turns, the type of
exhaust hood (wall cap), and all conditions noted below. Both
rigid and flexible metal duct are shown in the table below.
The correct exhaust installation is YOUR RESPONSIBILITY.
Problems due to incorrect installation are not covered
by the warranty.
EXHAUST SYSTEM CHECK LIST
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows Flexible
Metal
Rigid
Metal Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
0
1
2
3
4
55 Feet
40 Feet
30 Feet
20 Feet
15 Feet
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
45 Feet
30 Feet
20 Feet
15 Feet
10 Feet
Flexible
Metal
Use only for short
run installations
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
• Termination should present minimal resistance to the exhaust air flow
and should require little or no maintenance to prevent clogging.
Never install a screen in or over the exhaust duct.
This could cause lint build up.
• Wall caps must be installed at least 12 in. above ground level or any other
obstruction with the opening pointed down.
• If roof vents or louvered plenums are used, they must be equivalent to a
4-in. dampened wall cap in regard to resistance to air flow, prevention of
back drafts, and maintenance required to prevent clogging.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end of each section of
duct must point away from the dryer.
• Do not assemble the ductwork with fasteners that extend into the duct.
They will serve as a collection point for lint.
• Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with duct tape.
• Horizontal runs should slope down toward the outdoors 1/2 inch per foot
INSULATION
Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.
If using flexible metal duct, please refer to page 5.
EXHAUST LENGTH
EXHAUST LENGTH
EXHAUST LENGTH
EXHAUST LENGTHEXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows Flexible
Metal
Rigid
Metal Rigid
Metal
150 Feet
135 Feet
125 Feet
115 Feet
0
1
2
3
Flexible
Metal
Use only for short
run installations
If using flexible metal duct, please refer to page 5.
4
5
105 Feet
95 Feet
55 Feet
52 Feet
49 Feet
4 Feet6
43 Feet
40 Feet
125 Feet
115 Feet
105 Feet
95 Feet
85 Feet
75 Feet
45 Feet
42 Feet
39 Feet
3 Feet6
33 Feet
30 Feet