NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is your responsibility to contact a
TXDOL¿HG LQVWDOOHU WR PDNH WKH HOHFWULFDO
connections.
Installation
Instructions
Electric Dryer
02
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for local
inspector’s use.
IMPORTANT- Observe all governing codes and
ordinances.
Note to Installer - Be sure to leave these instructions with the
customer.
Note to Customer - Keep these instructions with your Owner’s
Manual for future reference.
Before the old dryer is removed from service or discarded,
remove the dryer door.
Inspect the dryer exhaust outlet and straighten the outlet
walls if they are bent.
Service information and the wiring diagram are located in the
control console.
Do not allow children on or in the appliance. Close supervision
of children is necessary when the appliance is used near
children.
Install the dryer where the temperature is above 50°F for
satisfactory operation of the dryer control system.
Product failure due to improper installation is not
covered under the warranty.
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
TOOLS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
4” COVER PLATE (IF NEEDED
(KIT WE1M454)
234D2004P002 31-16308 03-13 GE
Step 1 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust
is Clean (see section 1) and Meets Attached Installation
6SHFL¿FDWLRQVVHHVHFWLRQ
6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply & Venting.
Step 9 Place the Owner’s Manual and the Installation
Instructions in a location where they will be noticed by the
owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For garage installation (if allowed by local codes), see section 9.
For side or bottom exhaust, see section 10.
WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all
installation instructions.
Clothes dryer installation must be performed by a
TXDOL¿HGLQVWDOOHU
Install the clothes dryer according to these instructions
and in accordance with local codes.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the
clothes dryer to the outdoors.
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ
PDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLV
installed, it must be UL listed and installed in accordance
with the instructions found in Connecting The Dryer To
House Vent on page 5 of this manual. Flexible venting
materials are known to collapse, be easily crushed, and
WUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQG
LQFUHDVHWKHULVNRI¿UH
Do not install or store this appliance in any location
where it could be exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave
these instructions with the customer).
Install the clothes dryer according to the manufacturer’s
instructions and local codes.
Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
Installation Instructions
2
ELECTRICAL CONNECTION INFORMATION
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRICAL SHOCK AND
PERSONAL INJURY:
• DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
FRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/(/(&75,&$/
CODE, ANSI/NFPA NO. 70.
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January 1, 1996, the National Electric
code requires that the new constructions utilize a
4-wire connection to an electric dryer.
WARNING: Only a 4-conductor cord shall
be used when the appliance is installed in a location
where grounding through the neutral conductor is
prohibited. Grounding through the neutral is prohibited
for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes
prohibit grounding through the neutral conduction.
1. 7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
 5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN
4. 5HPRYHDQGGLVFDUGJURXQGVWUDS.HHSWKHJUHHQ
ground screw for step 7.
5. ,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole above strain relief bracket). Tighten
DOOWHUPLQDOEORFNVFUHZVVHFXUHO\
8. Properly secure power cord to strain relief.
9. 5HLQVWDOOWKHFRYHU
INTERNAL DUCT
OPENING CHECK THA T EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREE LY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit,
SURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRUFLUFXLWEUHDNHUV
$ IRXU RU WKUHHZLUH VLQJOH SKDVH 9 RU 9
+]DPSFLUFXLWLVUHTXLUHG,IWKHHOHFWULFVXSSO\GRHVQRW
PHHWWKHDERYHVSHFL¿FDWLRQVWKHQFDOODOLFHQVHGHOHFWULFLDQ
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent
ZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJFRQGXFWRUPXVW
be run with the circuit conductors and connected to the
HTXLSPHQWJURXQGLQJWHUPLQDORQWKHDSSOLDQFH
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
1PREPARING FOR INSTALLATION OF
NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
Remove and discard existing plastic or metal
foil transition duct and replace with UL listed
transition duct.
2
Screws
(2)
5HPRYHJURXQGVWUDS
and discard. Keep
green ground screw
Hot
Wire
5HORFDWH
green
ground
screw
here
Green
Wire
µ8/
5HFRJQL]HG
6WUDLQ5HOLHI
$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\
cord kit marked for use with dryers and provided with closed loop or
spade terminals with upturned ends (not supplied).
Fuse
Hot
Wire
Neutral
(white)
Strain
5HOLHI
Bracket
Cover
Screw
Installation Instructions
CONNECTING DRYER USING 3-WIRE
CONNECTION
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit grounding
through the neutral conduction.
1. 7XUQ RȺ WKH FLUFXLW EUHDNHUV  DPS RU UHPRYH WKH
dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
 5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN
4. ,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet
UHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
7. Properly secure power cord to strain relief.
8. 5HLQVWDOOWKHFRYHU
3 EXHAUST INFORMATION
WARNING - IN CANADA AND IN THE
UNITED STATES, THE REQUIRED EXHAUST
DUCT DIAMETER IS 4 IN (102mm). DO NOT
USE DUCT LONGER THAN SPECIFIED IN THE
EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
Increase the drying times and the energy cost.
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect installation
are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ
duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall cap),
and all conditions noted below. The maximum duct length
for rigid metal duct is shown in the table below.
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elb ows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
0
1
2
3
4
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
Use only for sho rt
run installations
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of
birds or other wildlife.
Termination should present minimal resistance to the
H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH
to prevent clogging.
Never install a screen in or over the exhaust duct. This could
cause lint build up.
Wall caps must be installed at least 12 in. above ground
level or any other obstruction with the opening pointed
down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and
exhaust hood.
TURNS OTHER THAN 90º
One turn of 45º or less may be ignored.
Two 45º turns should be treated as one 90º turn.
Each turn over 45º should be treated as one 90º turn.
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 9 elbow.
For the side exhaust installations, add one 90° elbow to the
chart.
The total vent system length includes all the straight portions
and elbows of the system (transition duct included).
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
N
Screws
(2)
Green Ground Screw
& Ground Strap
Hot
Wire
µ8/
5HFRJQL]HG
6WUDLQ5HOLHI
$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\
cord kit marked for use with dryers and provided with closed loop or
spade terminals with upturned ends (not supplied).
Fuse
Hot
Wire
Neutral
(white)
Strain
5HOLHI
Bracket
Cover
Screw
If required, by local code, install external
ground (not provided) to grounded metal,
cold water pipe, or other established
ground determined by a qualified
electrician.