GE DBXR463EGCC Bedienungsanleitung

GE Wäschetrockner DBXR463EGCC

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für GE DBXR463EGCC (8 Seiten) in der Kategorie Wäschetrockner. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
Installation
Instructions
Electric Dryer
05
TOOLS YOU
WILL NEED
MATERIALS YOU WILL NEED
PHILLIPS SCREWDRIVER
SLIP JOINT PLIERS
LEVEL
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
NOTE: Installation and service of this dryer requires basic
mechanical and electrical skills. It is your responsibility to
contact a qualified installer to make the electrical connections.
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
Step 1 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3 Remove the Foam Shipping Pads (see section 1).
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply
and Venting.
Step 9 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
FLAT BLADE SCREWDRIVER
DUCT TAPE
WARNING RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation instruc-
tions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance
with local codes.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the
outdoors.
Do not install or store this appliance in any location where it could be
exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with
the customer).
DO NOT install a clothes dryer with flexible plastic ducting materials. If
flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed
and installed in accordance with the instructions found in "Connecting The
Dryer To House Vent" on page 5 of this manual. Flexible venting materials
are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
Questions on Installation? Call: 1-800-GECARES (US)
www.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT- Save these
instructions for local inspector’s use.
IMPORTANT- Observe
all governingcodes and ordinances.
Note to Installer - Be sure to leave these
instructions with e omth cust er.
Note to Customer - Keep these instruct-
ions with your Use and Care Book for
future reference.
Before the old dryer is removed from
service or discarded, remove the dryer
door.
Service information and the wiring dia-
gram are located in the control console.
Do not allow children on or in the appli-
ance. Close supervision of children is
necessary when the appliance is used
near children.
Install the dryer where the temperature
is above 50°F for satisfactory operation of
the dryer control system.
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
Installation Instructions
1 PREPARING FOR INSTALLATION
OF NEW DRYER
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for installation and service.
2 ELECTRICAL CONNECTION
INFORMATION
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
2
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
DO NOT E AN EXTENSION CORD OR ANUS
ADAPTER PLUG WITH THIS A LIANCE.PP
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local
codes, in accordance with the NAT NAL ELECTRI-IO
CAL C E, ANSI/NFPA NO. 70. OD
WAR NG - TO DUCE THE RISK OFNI RE
FIRE, ELECTRICAL SHOCK AND PERSONAL
I URY:NJ
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit,
protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz,
30 amp circuit is required.
If the electric supply does not meet the above specifications, then
call a licensed electrician.
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor must be run
with the circuit conductors and connected to the equipment-
grounding terminal on the appliance.
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
WARNING:Only a 4-conductor cord shall be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral is
prohibited for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: SInce January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to
an electric dryer
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
3
Installation Instructions
1. Turn off the circuit breaker(s) (30 amp) or remove the dryer’s
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove the power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord
entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet
rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
CONNECTING DRYER USING 3-WIRE
CONNECTION
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER 3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green
ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power
cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green ground
screw (hole above strain relief bracket). Tighten all
terminal block screws (3) completely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
Termination should present minimal resistance to the exhaust air flow
and should require little or no maintenance to prevent clogging.
Never
install a screen in or over the exhaust duct.
This could cause lint build up.
Wall caps must be installed at least 12 in. above ground level or any other
obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
One turn of 45º or less may be ignored.
Two 45º turns should be treated as one 90º turn.
Each turn over 45º should be treated as one 90º turn.
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end of each section of
duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the duct.
They will serve as a collection point for lint.
Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with duct tape.
Horizontal runs should slope down toward the outdoors ½ inch per foot
INSULATION
Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.
3 EXHAUST INFORMATION
WARNING - IN CANADA AND IN THE UNITED
IS 4 IN (102mm). DO NOT USE DUCT LONGER
STATES, THE REQUIRED EXHAUST DUCT DIAMETER
THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of duct,
number of turns, the type of exhaust hood (wall cap), and all
conditions noted below. The maximum duct length for rigid
metal duct is shown in the table below.
The correct exhaust installation is YOUR RESPONSIBILITY.
Problems due to incorrect installation are not covered
by the warranty.
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
Remove and discard existing plastic or metal foil transition
duct and replace with UL listed transition duct.


Produktspezifikationen

Marke: GE
Kategorie: Wäschetrockner
Modell: DBXR463EGCC

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE DBXR463EGCC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Wäschetrockner GE

Bedienungsanleitung Wäschetrockner

Neueste Bedienungsanleitung für -Kategorien-